App- and Wearable-Based Remote Monitoring for Patients With Myasthenia Gravis and Its Specialists: Feasibility and Usability Study

App- and Wearable-Based Remote Monitoring for Patients With Myasthenia Gravis and Its Specialists: Feasibility and Usability Study

App- and Wearable-Based Remote Monitoring for Patients With Myasthenia Gravis and Its Specialists: Feasibility and Usability Study

1Department of Neurology with Experimental Neurology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, Berlin, Germany

2Digital Health Center, Berlin Institute of Health at Charité, Charité Universitätsmedizin Berlin, Berlin, Germany

3Department of Neurology, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, MA, United States

4Neuroscience Clinical Research Center, Department of Neurology with Experimental Neurology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

5Institute of Biometry and Clinical Epidemiology, Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

6Center for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany

*these authors contributed equally

Corresponding Author:

Maike Stein, MD


Background: Myasthenia gravis (MG) is rare, chronic autoimmune disorder of the neuromuscular junction that requires specialized care and often lifelong treatment, facing challenges due to its rarity and the limited availability of specialists. Telemedical solutions in specialized centers hold considerable promise in bridging this gap by increasing access to this care to a broader patient population in a timely manner. However, there is no research regarding interventional remote care solutions in the field of MG to date.

Objective: This study aimed to assess the feasibility and usability among patients with MG and specialists of a telemedicine platform, tailored to patients with MG and designed to facilitate remote monitoring, treated in a specialized center.

Methods: The telemedicine platform consisted of an app for patients and a web-based portal for physicians. Over a period of 3 months, 30 patients continuously monitored their vital parameters through external devices, including a digital spirometer and a wearable (activity tracker). Furthermore, patients completed 7 different patient-reported outcome measures (PROMs) through the app at predefined intervals. Specialists could review this monitoring data and adjust therapy as necessary. In addition, communication between patients and physicians was facilitated through a chat module. Feasibility was evaluated by total adherence rates for completing PROMs within the app, alongside the collection of spirometry and wearable data. Furthermore, user satisfaction was assessed among both patients with MG and physicians at the end of study.

Results: Total adherence rates ranged from 74.3% (1830/2464) to 97.9% (327/334) across all data types, with the highest adherence observed for PROMs (1139/1179, 96.6%), followed by spirometry (293/334, 87.7%) and wearables (1830/2261, 80.9%). Notably, patients wore the wearable longer than required by protocol and conducted a higher number of spirometry measurements during the study than required per protocol (median 20 h/d [IQR 15-24] vs 14 h/d and median 49 [IQR 15-59] measurements vs 11 measurements, respectively). Technical issues and discomfort with wearables were factors affecting lower adherence in some patients. The System Usability Scale yielded a median score of 85 indicating “excellent usability.” In addition, results from a more detailed user evaluation questionnaire showed high levels of user satisfaction among both patients and health care professionals across diverse categories, including their experience of the care program, communication, and evaluation of the program.

Conclusions: Remote monitoring of patients with MG through the telemedical platform demonstrated good feasibility and acceptability, as evidenced by above-average adherence rates and user satisfaction for both patients and physicians. The majority of patients wanted to continue using the app. These findings highlight the potential for user-friendly digital tools to enhance care for patients with MG, although addressing technical challenges and ensuring patient comfort with wearables are essential for optimal implementation. Further research involving larger cohorts and longer study duration is warranted to validate these findings.

Trial Registration: Deutsches Register Klinischer Studien DRKS00029907; https://drks.de/search/en/trial/DRKS00029907

JMIR Form Res 2025;9:e58266

doi:10.2196/58266

Keywords



Myasthenia gravis (MG) is a rare autoimmune disease characterized by specific autoantibodies targeting the postsynaptic membrane of the neuromuscular junction, resulting in fluctuating fatigability and weakness of ocular, bulbar, and skeletal muscles, with the potential for life-threatening crises [Gilhus NE, Tzartos S, Evoli A, Palace J, Burns TM, Verschuuren J. Myasthenia gravis. Nat Rev Dis Primers. May 2, 2019;5(1):1-19. [CrossRef]1]. MG has a bimodal incidence pattern, with younger women and older men being most commonly affected [Vinciguerra C, Iacono S, Bevilacqua L, et al. Sex differences in neuromuscular disorders. Mech Ageing Dev. Apr 2023;211:111793. [CrossRef] [Medline]2]. Given its chronic nature, the majority of patients with MG require long-term and often lifelong, highly specialized care and therapy [Narayanaswami P, Sanders DB, Wolfe G, et al. International consensus guidance for management of myasthenia gravis: 2020 Update. Neurology (ECronicon). Jan 19, 2021;96(3):114-122. [CrossRef] [Medline]3]. Furthermore, studies have shown that patients with MG experience a significantly reduced quality of life [Lehnerer S, Jacobi J, Schilling R, et al. Burden of disease in myasthenia gravis: taking the patient’s perspective. J Neurol. Jun 2022;269(6):3050-3063. [CrossRef] [Medline]4] and have a high demand for individualized counseling on various topics [Stein M, Hoffmann S, Gerischer L, et al. Myasthenia gravis - a retrospective analysis of e-mail inquiries made to a patient organisation and specialized center to uncover unmet needs from patients and caregivers. BMC Neurol. Dec 7, 2022;22(1):455. [CrossRef] [Medline]5] and supportive interactions. In addition, characteristic symptom fluctuations are not captured effectively by conventional clinical assessments that rely on infrequent in-person assessments that are further challenged due to documentation overload for physicians, limited consultation time, and geographical barriers that limit access to specialists [Masanneck L, Räuber S, Schroeter CB, et al. Driving time-based identification of gaps in specialised care coverage: An example of neuroinflammatory diseases in Germany. Digit Health. 2023;9:20552076231152989. [CrossRef] [Medline]6] . The characteristic symptom fluctuations in MG, but also the long intervals for therapies to effectively influence the disease including potential side effects, give rise to questions and challenges for timely therapy adjustments and individual counseling. However, in practice, these adjustments often do not occur in a timely manner or are conducted in ways that pose data privacy problems, are resource intensive and lack standardization. These challenges and the growing demand for personalized and on-demand available health care have spurred the development of telemedical and wearable devices for remote patient monitoring [Holko M, Litwin TR, Munoz F, et al. Wearable fitness tracker use in federally qualified health center patients: strategies to improve the health of all of us using digital health devices. NPJ Digit Med. Apr 25, 2022;5(1):53. [CrossRef] [Medline]7]. Wearable devices such as activity trackers facilitate continuous monitoring of various health parameters and have shown promise in reducing hospitalization costs, improving personalized health management [Ramezani R, Cao M, Earthperson A, Naeim A. Developing a smartwatch-based healthcare application: notes to consider. Sensors (Basel). Jul 25, 2023;23(15):6652. [CrossRef] [Medline]8-Koehler F, Koehler K, Deckwart O, et al. Efficacy of telemedical interventional management in patients with heart failure (TIM-HF2): a randomised, controlled, parallel-group, unmasked trial. Lancet. Sep 22, 2018;392(10152):1047-1057. [CrossRef] [Medline]10] and health‐related quality of life [Smolis-Bąk E, Dąbrowski R, Piotrowicz E, et al. Hospital-based and telemonitoring guided home-based training programs: Effects on exercise tolerance and quality of life in patients with heart failure (NYHA class III) and cardiac resynchronization therapy. A randomized, prospective observation. Int J Cardiol. Nov 2015;199:442-447. [CrossRef]11]. Those digital health interventions hold potential for bridging the care gap by offering individualized support based on continuous health data derived from both subjective patient-reported outcome measures (PROMs) and objective wearable and sensor-based data. Although previous remote digital studies have shown the feasibility and usability of leveraging smartphones and wearable technology for assessing clinical changes in different diagnosis and naturalistic settings [Zhang Y, Pratap A, Folarin AA, et al. Long-term participant retention and engagement patterns in an app and wearable-based multinational remote digital depression study. NPJ Digit Med. Feb 17, 2023;6(1):25. [CrossRef] [Medline]12-De Angel V, Lewis S, White K, et al. Digital health tools for the passive monitoring of depression: a systematic review of methods. NPJ Digit Med. Jan 11, 2022;5(1):3. [CrossRef] [Medline]14], there is to date no data available on telemedical interventions for patients with MG. Generally, successful integration of these technologies into health care relies on patients’ active involvement and acceptance, underscoring the importance of digital literacy [Svennberg E, Tjong F, Goette A, et al. How to use digital devices to detect and manage arrhythmias: an EHRA practical guide. Europace. Jul 15, 2022;24(6):979-1005. [CrossRef] [Medline]15,Hillmann HAK, Soltani S, Mueller-Leisse J, Hohmann S, Duncker D. Cardiac rhythm monitoring using wearables for clinical guidance before and after catheter ablation. J Clin Med. Apr 26, 2022;11(9):2428. [CrossRef] [Medline]16]. In the context of remote monitoring technologies, adherence serves as a crucial measure of patient compliance with study protocols (eg, the completion rate of providing data inputs at specified frequencies outlined in the protocol) and is dependent on their willingness and capacity to adopt new behaviors and practices. We hypothesize that the integration of digital tools into clinical care presents a viable approach for remotely monitoring the condition and symptoms of patients with MG. The aim of this study was to evaluate the feasibility and user satisfaction levels among patients with MG and health care professionals with a telemedicine platform specifically tailored to monitor patients with MG and enabling patient-physician interaction.


Telemedical Platform for Patients with MG

The telemedical platform for patients with MG, “MyaLink” used in the study was developed at Charité Universitätsmedizin Berlin together with software partner Qurasoft GmbH (based on the SaniQ platform). The platform is a Conformité Européenne (CE)-marked class-I medical device (Medical Device Directive) and is GDPR (General Data Protection Regulation) and BlnDSG (Berlin Data Protection Act) compliant. The platform consists of an app for patients (iOS and Android) and a web-based portal for physicians facilitating to review patient data, manage and set up individual monitoring plans and medication plans. It offers a secure interactive platform for exchange of information and health data between physicians and patients and informed treatment decisions (Figure 1). The MyaLink app contains the following modules: (1) transmission and integration of sensor-based data from wearables including heart rate, oxygen saturation, and step count (device: Garmin Vivosmart 5); (2) assessment of the forced vital capacity from a digital spirometer (device: MIR Spirobank Smart One); (3) assessment of questionnaires and PROMs (see details under Section 3.5); and a (4) communication module for individual requests and patient-physician interaction. Furthermore, the app contains a (5) medication plan with reminder function and (6) a module including data storage of important documents (eg, clinical reports), which can also be shared with the physician through the web-based portal. The web-based system for physicians enables real time access to this data and allows clinicians to obtain an accurate overview of the patients’ condition and visualization of health data. If necessary, the patient can be contacted through the communication tool and adjustments to medication and the remote monitoring plans can be made.

Figure 1. Schematic overview of telemedical platform and its features (MyaLink): transmission and simultaneous integration of sensor-based data into the app is implemented by bluetooth from coupled external devices (wearable or digital spirometer). In addition, the platform facilitates the collection of patient-reported outcome measures (PROMs) through the app and a communication module enables interaction between patients and physicians. Health data can be shared with specialists who can review monitoring parameters through the web-based system and make therapy adjustments as needed. The data is transmitted between patient and physicians with double encryption (AES256, Advanced Encryption Standard). PROM: patient-reported outcome measure.

Subjects’ Eligibility

Inclusion and exclusion criteria have been previously presented in detail in our methods paper [Stein M, Meisel A, Moench M, et al. The telemedical platform myalink for remote monitoring in myasthenia gravis: rationale and protocol for a proof of concept study. MedRxiv. Preprint posted online on Jul 11, 2024. [CrossRef]17]. Inclusion criteria included patients with a diagnosis of MG for at least 6 months before study enrollment, aged 18 years and older, and classified according to the Myasthenia Gravis Foundation of America (MGFA) classification status I-IV [Jaretzki A 3rd, Barohn RJ, Ernstoff RM, et al. Myasthenia gravis: recommendations for clinical research standards. Task Force of the Medical Scientific Advisory Board of the Myasthenia Gravis Foundation of America. Neurology (ECronicon). Jul 12, 2000;55(1):16-23. [CrossRef] [Medline]18]. Exclusion criteria included patients with somatic, psychiatric, or neurological disorders who were undergoing treatments or were not stabilized under drug therapy that could adversely affect cognitive function. Patients were recruited through the specialized outpatient myasthenia center at Charité Universitätsmedizin Berlin.

Study Design

This analysis focused on data obtained from the telemedical intervention group from a randomized controlled trial (RCT) conducted at our specialized center at Charité Universitätsmedizin Berlin in Germany. The RCT included 45 patients with MG over a 12-week observation period between April and September 2023. Patients were randomized in a 2:1 ratio into the telemedical intervention group (n=30) or the control group (n=15), who received standard of care without telemedical intervention. Randomization was performed according to gender and clinical class stratified by MGFA score at baseline (using the randomizer tool [Randomization service for multicenter clinical trials. Randomizer. URL: https://www.randomizer.at/ [Accessed 2025-02-27] 19]). The primary objective of the study was to investigate the feasibility of the remote monitoring platform in care of patients with MG. Feasibility was measured through adherence rates based on completion of PROMs in the app and data collection from external devices (including a digital spirometer and activity tracker). Furthermore, user satisfaction with the telemedical platform was assessed among patients and health care professionals comprised of the study team (n=5) at the end of the study. We, therefore, exclusively analyzed data from the 30 patients from the intervention group. Secondary objectives of the study (but not part of this analysis) included comparing standard of care with and without additional telemedical intervention. This comparison focused on evaluating clinical endpoints between the control and intervention group. Comprehensive baseline and end-of-study visits were conducted at the study center for both groups and included an in-person clinical assessment of medical history, medication, hospitalizations for MG, care-related questions (eg, accessibility of a specialist or areas of improvement regarding MG treatment), various PROMs and MG-specific clinical assessment through the quantitative myasthenia gravis score (QMGS) [Barohn RJ, McIntire D, Herbelin L, Wolfe GI, Nations S, Bryan WW. Reliability testing of the quantitative myasthenia gravis score. Ann N Y Acad Sci. May 13, 1998;841:769-772. [CrossRef] [Medline]20]. At baseline, the intervention group received a wearable (activity tracker) and a digital spirometer, along with the MyaLink app, which were set up and connected on the patients’ smartphone. Instructions on app and external devices usage were provided by the study team. This enabled remote health monitoring throughout the study by active (PROMs and spirometry) and passive (wearable) continuous data collection. Patients were instructed to fill out PROMs and perform spirometry at predefined intervals. They were instructed to wear the wearable during waking hours (at least 14 h per day) throughout the study period and optionally at night. Telemedical check-ups occurred in weeks 4 and 8, comprising the reviewing of remote monitoring data by study physicians and contacting the patients if necessary (eg, changing medication). Patients could also initiate communication through the chat module at any time, with physicians monitoring messages on weekdays during working hours and responding within 24 hours. Patients completed usability questionnaires through the app a week before the end of the study, while health care professionals conducted their questionnaires after study completion. Furthermore, oral feedback from patients was collected and documented during the end-of-study visit. All data from the study visits and all data from the telemedical check-up was documented in REDCap (Research Electronic Data Capture) software (version 13.7.31; Vanderbilt University).

Patient-Reported Outcome Measures and Data From App

In total, 6 questionnaires and 1 test were assigned to patients through the app, administered weekly or monthly, depending on their specific type (Figure 2). Weekly questionnaires included the myasthenia gravis activities of daily living (MG-ADL) profile [Wolfe GI, Herbelin L, Nations SP, Foster B, Bryan WW, Barohn RJ. Myasthenia gravis activities of daily living profile. Neurology (ECronicon). Apr 22, 1999;52(7):1487-1489. [CrossRef] [Medline]21], myasthenia gravis quality of life, revised (MG-QoL15r) [Burns TM, Sadjadi R, Utsugisawa K, et al. International clinimetric evaluation of the MG-QOL15, resulting in slight revision and subsequent validation of the MG-QOL15r. Muscle Nerve. Dec 2016;54(6):1015-1022. [CrossRef] [Medline]22], and single simple question (SSQ) [Abraham A, Breiner A, Barnett C, Katzberg HD, Bril V. The utility of a single simple question in the evaluation of patients with myasthenia gravis. Muscle Nerve. Feb 2018;57(2):240-244. [CrossRef] [Medline]23], which are commonly used in MG studies including large approval studies to assess functional status and quality of life. Patients were also instructed to perform a weekly breath count test [Kukulka K, Gummi RR, Govindarajan R. A telephonic single breath count test for screening of exacerbations of myasthenia gravis: A pilot study. Muscle Nerve. Aug 2020;62(2):258-261. [CrossRef] [Medline]24]. Monthly questionnaires included Chalder Fatigue Scale (CFS 11) [Spitzer RL, Kroenke K, Williams JB. Validation and utility of a self-report version of PRIME-MD: the PHQ primary care study. Primary care evaluation of mental disorders. Patient health questionnaire. JAMA. Nov 10, 1999;282(18):1737-1744. [CrossRef] [Medline]25] and Hospital Anxiety and Depression Scale (HADS) [Zigmond AS, Snaith RP. The hospital anxiety and depression scale. Acta Psychiatr Scand. Jun 1983;67(6):361-370. [CrossRef] [Medline]26] to assess common comorbidities in MG. In addition, Patient Acceptable Symptom State (PASS) was assessed monthly [Mendoza M, Tran C, Bril V, Katzberg HD, Barnett C. Patient-acceptable symptom states in myasthenia gravis. Neurology (ECronicon). Sep 22, 2020;95(12):e1617-e1628. [CrossRef] [Medline]27]. Furthermore, patients completed 2 user satisfaction questionnaires at the end of the study. For broad comparability, patients completed the System Usability Scale (SUS) [Brooke J. SUS: A quick and dirty usability scale. In: Usability Evaluation in Industry. Taylor & Francis; 1995:189-194.28], where patients ranked each of the 10 statements from 1 to 5 based on how much they agreed with the statement. The second questionnaire was adapted from Braun et al [Braun M, Schmidt O, Schultz T, Woehrle H, Sundrup MG, Schöbel C. Erfahrungen mit der digitalen Versorgung von Patienten mit chronischen und akuten Lungenerkrankungen während der SARS-CoV-2-Pandemie [Article in German]. Internist. Mar 2022;63(3):255-265. [CrossRef]29] and specifically tailored to the MyaLink telemedical platform. It features 17 items categorized in 3 sections and uses a 4-point Likert scale (strongly agree to strongly disagree). Originally formulated in German for publication purposes, it underwent consensus translation into English by 4 medical health care professionals, including 1 native speaker. After the study, the study team completed a modified version of the questionnaire adapted from Braun et al for health care professionals, respectively.

Figure 2. Monitoring plan and frequencies of assessed parameters: Active (PROMs, respiratory function assessment) and passive data (wearable data) were collected during the study period. PROMs data were collected weekly or monthly, depending on the questionnaire. Respiratory function assessment, assessed through breath count test and spirometry, was conducted weekly by the protocol. The collection of wearable data was continuous, with steps aggregated by the hour. PROMs: patient-reported outcome measures; MG-ADL: myasthenia gravis activities of daily living; MG-QoL15r: myasthenia gravis quality of life, revised; SSQ: single simple question; PASS: Patient Acceptable Symptom State; CFS: Chalder Fatigue Scale; HADS: Hospital Anxiety and Depression Scale.

Data From External Device or Wearable

Patients were instructed to perform spirometry measurements weekly, with reminders sent through the app through push notifications. The wearable continuously collected oxygen saturation level (every minute), heart rate (every minute), and steps (hourly aggregated). Data from both the digital spirometer and the wearable were transmitted directly to the app by bluetooth. The study team regularly checked the web-based system to ensure receipt of data from external devices and questionnaires, sending reminder messages through the chat module when necessary.

Analysis

The statistical calculations were performed using R software (version 4.2.2; R Foundation for Statistical Computing) [R. The R Project for Statistical Computing. URL: https://www.r-project.org/ [Accessed 2020-09-11] 30]. Descriptive statistics (median [IQR] and absolute and relative frequencies) are presented depending on the scale of the variables.

Feasibility was assessed by adherence rates. For PROMs, assignments of the questionnaire started a week or month after the baseline visit respectively, depending on the questionnaire. Questionnaires were assigned together with a push notification on the patient’s phone and disappeared from the app upon completion or were “overwritten” upon receiving a new assignment. Questionnaires could only be submitted by patients through the app if they were fully completed. Each questionnaire was required to be completed within 7 days to be counted as “completed,” including the monthly assigned questionnaires, with missing entries calculated accordingly. The final day for data acquisition from the last assigned weekly questionnaires ended the day before the end-of-study visit. Total adherence rates were calculated as the total number of completed questionnaires divided by the total number of assigned questionnaires. Additional questionnaire assignments were allowed in cases of clinical deterioration but were excluded from adherence calculations. The study was considered successful if at least 60% of assigned PROMs through the app were answered by patients of the intervention group. Across the 30 patients of the intervention group, a mean adherence rate and a 2-sided 95% CI are determined. If the observed average adherence is at least 76%, with data from 30 patients, the 95% CI would range from 60.7% to 91.3%, thus exceeding the 60% threshold.

Spirometry adherence rates were calculated accordingly (ratio of the total number of actual measurements performed during the study vs total number of measurements required per the study protocol).

Adherence calculations for wearable data included measurements starting the day after the baseline visit and ending the day before the end-of-study visit. Adherence to wearable data from the activity tracker was evaluated by aggregating data over hourly windows, with 100% adherence defined as wearing the device for 14 hours per day per patient (based on the estimated waking hours). This was then extrapolated over the study duration. Each hour necessitated at least one heart rate measurement to validate wear time, considering heart rate a more reliable marker than oxygen saturation. Overall adherence was determined by the sum of the hours the patients had with at least one heart rate measurement divided by sum of the hours per day corresponding to 100% individual adherence.

The user satisfaction questionnaire was descriptively evaluated using the Likert scale. The SUS ranked each of the 10 statements from 1 to 5 based on user agreement, from which a SUS score was calculated: Each patient responses undergo conversion into a new numerical value (0‐4), which is then aggregated and multiplied by 2.5 to transform the original scoring range of 0‐40 into a 0‐100 scale. These scores do not represent percentages but a percentile ranking [Bangor A, Kortum PT, Miller JT. An empirical evaluation of the System Usability Scale. Int J Hum Comput Interact. Jul 29, 2008;24(6):574-594. [CrossRef]31]. Research suggests that a SUS score above 68 is considered acceptable, with scores below 68 classified as not acceptable. Therefore, a score above 68 on the SUS is interpreted as a positive result further supporting the platform’s usability. A more detailed classification considers SUS scores between 73 and 84 as good, between 85 and 99 as excellent, and 100 as the best.

This analysis focuses on the primary study endpoints assessing feasibility and usability. Further exploratory analyses of secondary endpoints, eg, comparative clinical endpoint analyses (between control group and intervention group), evaluations of communication patterns from the MyaLink chat and telemedical interventions are currently prepared and results will be presented in further studies.

Ethical Considerations

This study received ethics approval by the ethics committee at Charité Universitätsmedizin Berlin (EA2/157/22). Written informed consent was obtained from the study participants before the start of the study. The study was conducted in accordance with the Declaration of Helsinki (2013) and its later amendments. Data storage and handling responsibilities were approved by the ethics committee of Charité Universitätsmedizin Berlin. The data collected through MyaLink is stored on certified data servers, which adhere to a management system according to ISO/IEC 27001:2013.


Patient Characteristics

Patients were between 23 and 82 years (median 47.5 years; IQR 40.5-57.5) at time of enrollment. The majority of patients were female (21/30, 70%). Most patients in the study had a mild to moderate disease severity, with 36.7% (11/30) categorized in MGFA II (a or b) status and 43.3% (13/30) in MGFA III (a or b) status at the time of enrolment. Median scores for MG-ADL and QMG were 10 (IQR 5.25-11) and 15.5 points (IQR 12.25-20.75), respectively. On average, patients were diagnosed 5.5 years (IQR 2-9.75) before entry in the study. One patient withdrew from the study due to health reasons unrelated to MG. All results presented include data from the dropout, including measurements taken before the time of dropout (with the patient’s consent). Detailed patient characteristics are presented in Table 1.

Table 1. Patient characteristics: age, clinical class, time since diagnosis, study duration, and operating system for intervention group as well as subgroups (female and male).
CharacteristicsOverall (n=30)Female (n=21)Male (n=9)
Age, median (IQR)47.5 (40.5‐57.5)47 (42‐53)56 (40‐60)
MGFAa score, n (%)
 I1 (3.3)0 (0)1 (11.1)
 IIa5 (16.7)4 (19)1 (11.1)
 IIb6 (20)3 (14.3)3 (33.3)
 IIIa3 (10)2 (9.5)1 (11.1)
 IIIb10 (33.3)8 (38.1)2 (22.2)
 IVa0 (0)0 (0)0 (0)
 IVb5 (16.7)4 (19)1 (11.1)
MG-ADLb score, median (IQR)10 (5.25‐11)10 (5‐11)9 (6-12)
MG-QoL15rc score, median (IQR)15.5 (12.25‐20.75)17 (12‐21)13 (13‐19)
QMGd score, median (IQR)15 (12.25‐17)15 (13‐18)14 (10‐15)
Years since MGe diagnosis, median (IQR)5.5 (2‐9.75)5 (2-10)7 (4-9)
System, n (%)
 Android19 (63.3)15 (71.4)4 (44.4)
 iOS11 (36.7)6 (28.6)5 (55.6)
Days between baseline and end-of-study visit, median (IQR)84 (84‐85)84 (83‐85)84 (84‐86)
Dropout, n (%)1 (3.3)1 (4.8)0 (0)

aMGFA: Myasthenia Gravis Foundation of America.

bMG-ADL: myasthenia gravis activities of daily living.

cMG-QoL15r: myasthenia gravis quality of life, revised.

dQMG: quantitative myasthenia gravis.

eMG: myasthenia gravis.

Adherence

The total adherence rates for PROMs and external devices data ranged from 74.3%- 97.9% (1830/2464 - 327/334) across all data types and are detailed in Table 2. When examining adherence by data category, adherence to PROMs was the highest, followed by spirometry, and then wearable data from the activity tracker.

Table 2. Total adherence rates for different data groups.
Data groupAdherence (total completed/total assigned), n/N (%)
Overall PROMsa1139/1179 (96.6)
 MG-ADLb321/334 (96.1)
 MG-QoL15rc325/334 (97.3)
 SSQd327/334 (97.9)
 CFSe55/59 (93.2)
 HADSf5/59 (93.2)
 PASSg56/59 (94.9)
Breath count test326/334 (97.6)
Spirometry
 FVCh293/334 (87.7)
Wearables (at least 14 h per day)
 Pulse1830/2464 (74.3)
 Pulse (excluding days without any wearable measurement from the analysis)1830/2261 (80.9)

aPROMS: patient-reported outcome measures.

bMG-ADL: myasthenia gravis activities of daily living.

cMG-QoL15r: myasthenia gravis quality of life, revised.

dSSQ: single simple question.

eCFS: Chalder Fatigue Scale.

fHADS: Hospital Anxiety and Depression Scale.

gPASS: Patient Acceptable Symptom State.

hFVC: forced vital capacity.

Adherence to PROMs ranged between 93.2% (55/59) and 97.9% (327/334), depending on the specific questionnaire. Patients were assigned weekly questionnaires and spirometry measurements between 11 and 13 times (drop out: 5 times) during the study, depending on individual study duration of a participant. Monthly questionnaires were assigned twice to all patients (drop out: 1). There was no difference in adherence regarding the questionnaire frequency. For the breath count test, adherence was 97.6% (326/334). Adherence to spirometry was slightly lower than PROMs (293/334, 87.7%), likely due to the higher task burden associated with these active measurements (Figure 3). Patients conducted a median of 49 spirometry measurements (IQR 15-59).

Figure 3. Adherence of spirometry measurements: The blue circles represent the end-of-study visit for each patient, while the red line indicates week 12, marking the duration of the study. Each black vertical line indicates when a spirometry measurement was assigned according to the study protocol (weekly intervals). Patients were given a 7-day window until the next weekly assignment for measurement to qualify as “completed.” The black dots mark the times when the patient actually performed the spirometry measurement. Each measurement from the digital spirometer was timestamped and subsequently automatically transmitted to the app through bluetooth, with the values being integrated accordingly. FVC: forced vital capacity.

On average, patients wore the wearable for a median duration of 20 hours per day (IQR 15‐24). Wearable adherence rates exhibited considerable variability among patients, ranging from 6.8% (4/59) to 100% (83/83) (Figure 4), despite an overall strong adherence of 80.9% (1830/2261) for all patients during the study when excluding days without any data input (no recorded heart rate measurements) from the calculation (Table 2). Including days without wearable data input to the calculation decreased adherence to 74.3% (1830/2464). Clinical insights from chat interactions, as evidenced by the timestamps within the chat messages, unveiled several factors impacting patients with decreased device use. For example, out of the 30 patients, 2 patients (6.7%) experienced a myasthenic crisis necessitating prolonged hospitalization and reported having forgotten the devices at home. Furthermore, 1 patient (3.3%) had difficulty with using the app (older patient who was overwhelmed by the technical operation and conducting measurements with the digital spirometer) with numerous interactions with the software provider’s support team. Some patients experienced discomfort with the rubber strap of the activity tracker. Some patients had device-related issues such as (recurring) pairing problems and 1 out of the 30 patients (3.3%) received a defective activity tracker, necessitating a device replacement. However, even after replacement the patient reported ongoing connectivity issues between the wearable and his smartphone.

Figure 4. Adherence rates for wearable data from the activity tracker: Days since baseline visit on the X-axis, with patients represented on the Y-axis and the adherence rate per patient in the column on the right side. Days with wearable usage of at least 14 hours per day were classified as compliant (marked in green). A wearable hour was counted if at least one heart rate measurement value was recorded per hour. Days with less than 14 hours of wearable usage per day were marked as red. Days without any recorded heart rate measurements were marked in gray and excluded from the analysis.

User Satisfaction

The highest levels of agreement were observed in the following order: experience with the care program, communication, and evaluation of the program. Regarding the care program evaluation, 89.7% (26/29) agreed that the app was easy to use while 93.1% (27/29) agreed that the time investment required for app usage was appropriate. In total, 89.6% (26/29) of patients agreed that describing their health status during follow-up appointments was easier. A total of 93.1% (27/29) indicated that treating physicians were interested in reviewing the collected monitoring parameters. In addition, 79.3% (23/29) of patients agreed that their quality of life had significantly improved since app usage. Futhermore, 96.6% (28/29) expressed willingness to recommend the app to other patients. In addition, 69% (20/29) agreed that they felt more confident in identifying MG-specific problems using the app. Views on the reduction of visits to neurologists or clinics were mixed; 55.2% (16/29) agreed to needing fewer visits to neurologists, while 51.7% (15/29) agreed to reduced visits to clinics, with 13.8% (4/29) strongly disagreeing with both categories (Figure 5). Out of the 29 patients, 14 patients (46.7%) responded that they did not agree that they required less frequent hospital visits; of those 14 patients, 8 patients (57.1%) were hospitalized during the study period due to MG (two of whom were in intensive care). In addition, 7 of these 14 patients (50%) experienced at least one exacerbation. Results of user evaluation from the health care professionals showed similar high acceptance rates regarding the telemedical platform, ease of use, and overall positive evaluation on the effect on patient care (Figure 6).

Figure 5. User evaluation for patients: The questionnaire was divided into 3 categories: “Experience with the care program,” “Communication and Interaction” and “Evaluation of the program.” All 17 questions could be answered using a 4-point Likert scale ranging from 1 (strongly agree) to 4 (strongly disagree).
Figure 6. User evaluation for health care professionals: The questionnaire was divided into 3 categories: “Experience with the care program,“ “Communication and Interaction,” and “Evaluation of the program.” All 17 questions could be answered using a 4-point Likert scale ranging from 1 (strongly agree) to 4 (strongly disagree). Depending on the role within the study team (eg, physician and study nurse), only certain questions in the questionnaire could be answered.

The overall median SUS score was 85 (IQR 75-90). Figure 7 shows that there was a high level of agreement regarding the system’s ease of use (26/29, 90%), patients’ confidence in operating it (25/29, 86%), and patients’ belief that others would quickly learn to use the app (25/29, 86%). Notably, 21% (6/29) remained neutral regarding perceived inconsistencies in the app, although the majority (20/29, 69%) tended to disagree. Among patients (N=22) who responded at least once with a neutral (Likert-scale 3) or negative response to any question (agreeing or strongly agreeing with negatively formulated questions or disagreeing or strongly disagreeing with positively formulated questions), there were 14 females (63.6%) with a median age of 47.5 (IQR 39.25-61.25; mean 49.7, SD 15.70), and the MG-ADL score at baseline was median 9.5 (IQR 5-11; mean 8.5, SD 3.60). Of all 29 patients, 69% (20/29) expressed willingness to use the app regularly. Among the patients who responded negatively or neutral to this statement, the documented oral feedback collected at the end-of-study visit mainly encompassed technical feedback, such as suggestions for adjusting the size of the chat window, implementing filter options for monitoring parameters in the health diary, and presenting preferences for the parameter dashboard. Furthermore, patients also frequently noted necessary improvements for a more user-friendly medication plan. In addition, there were critiques regarding the omission of specific symptoms in the PROMs (eg, nonmotor symptoms, pain, and sleep) and requests from patients for a free-form diary function (eg, for documenting infections or daily fluctuations).

Figure 7. The System Usability Scale (SUS) uses a 10-item questionnaire with 5 response options for respondents, ranging from strongly agree to strongly disagree. Due to rounding, the percentage for Question 2 (“I feel confident using the app”) is 99% instead of 100%.

Our study evaluated the feasibility and usability of a telemedicine platform for patient-physician interaction and monitoring for MG, incorporating wearable data collection. Feasibility, measured by adherence, ranged from 74.3%- 97.9% (1830/2464 - 327/334) across all data types, with the highest adherence observed for completion of PROMs (1139/1179, 96.6%) within the app, followed by adherence to spirometry measurements (293/334, 87.7%), and then wearable adherence (1830/2261, 80.9%). Next to adherence, user satisfaction among patients and health care professionals was assessed and generally rated high to very high across different categories (care program, communication, and evaluation of the program) and considered “excellent” according to the SUS score. The majority of patients stated their willingness to continue using the app.

Our results demonstrate that the introduction of such a digital tool in a clinical setting is feasible and facilitates clinical monitoring regardless of age or gender. These findings represent the first results in the field of MG for telemedical intervention. There was mutual acceptance from both health care professionals and patients, as evidenced by the high adherence rates and good to very good user satisfaction assessed at the end of the study.

Overall, patients demonstrated greater engagement with the app questionnaires compared with data collection through wearables and spirometry. Passive data collection by wearables displayed higher adherence rates than active spirometry, interestingly diverging from previous research [Wahle F, Kowatsch T, Fleisch E, Rufer M, Weidt S. Mobile sensing and support for people With depression: a pilot trial in the wild. JMIR Mhealth Uhealth. Sep 21, 2016;4(3):e111. [CrossRef] [Medline]32]. Consistent with previous clinical studies [Jacoby SF, Robinson AJ, Webster JL, Morrison CN, Richmond TS. The feasibility and acceptability of mobile health monitoring for real-time assessment of traumatic injury outcomes. Mhealth. 2021;7:5. [CrossRef] [Medline]33-Chan YFY, Wang P, Rogers L, et al. The Asthma Mobile Health Study, a large-scale clinical observational study using ResearchKit. Nat Biotechnol. Apr 2017;35(4):354-362. [CrossRef] [Medline]35], there was a variability particularly in wearable adherence. Our additional clinical data from the chat interactions revealed that commonly technical issues (eg, pairing problems and device malfunction) and discomfort (eg, wristband intolerance) were factors contributing to lower adherence rates for some patients. Only 1 patient consistently experienced difficulties (and ultimately discontinued wearable use). However, patients wore the device significantly longer than required by the study protocol, including during nighttime (median 20 h per day (IQR 15-24)). Similarly, spirometry was performed more frequently than required by protocol (49 measurements (median; IQR 15-59)). This indicates a high need and willingness of patients to monitor their own symptoms. Our study results align with broader research on telemedicine for chronic diseases, demonstrating high feasibility and user acceptance, consistent with findings in other disorders. Similar to studies in palliative care in cancer patients [Pavic M, Klaas V, Theile G, et al. Mobile health technologies for continuous monitoring of cancer patients in palliative care aiming to predict health status deterioration: a feasibility study. J Palliat Med. May 2020;23(5):678-685. [CrossRef] [Medline]36], depression monitoring [Pedrelli P, Fedor S, Ghandeharioun A, et al. Monitoring changes in depression severity using wearable and mobiles ensors. Front Psychiatry. 2020;11:584711. [CrossRef] [Medline]37] and heart failure [Werhahn SM, Dathe H, Rottmann T, et al. Designing meaningful outcome parameters using mobile technology: a new mobile application for telemonitoring of patients with heart failure. ESC Heart Fail. Jun 2019;6(3):516-525. [CrossRef] [Medline]38], our results confirm the feasibility of continuous monitoring through mobile technologies for chronic conditions. With an adherence rate of 80.9% (1830/2261) for wearables, our study falls at the higher end of reported ranges (53%‐94%) [Pavic M, Klaas V, Theile G, et al. Mobile health technologies for continuous monitoring of cancer patients in palliative care aiming to predict health status deterioration: a feasibility study. J Palliat Med. May 2020;23(5):678-685. [CrossRef] [Medline]36-Naslund JA, Aschbrenner KA, Bartels SJ. Wearable devices and smartphones for activity tracking among people with serious mental illness. Ment Health Phys Act. Mar 2016;10:10-17. [CrossRef] [Medline]43]. However, the higher adherence rates for active data (PROMs) over passive data (wearables) in our results contrasts with other studies finding [Midaglia L, Mulero P, Montalban X, et al. Adherence and satisfaction of smartphone- and smartwatch-based remote active testing and passive monitoring in people with multiple sclerosis: nonrandomized interventional feasibility study. J Med Internet Res. Aug 30, 2019;21(8):e14863. [CrossRef] [Medline]40,Sohn A, Speier W, Lan E, et al. Integrating remote monitoring into heart failure patients’ care regimen: A pilot study. PLoS One. 2020;15(11):e0242210. [CrossRef] [Medline]42], indicating potential disease-specific differences requiring further investigation. In addition, patients’ sense of control during active data input or technical challenges with wearables could have affected adherence to passive monitoring. Still, comparison with other studies for different diseases remains difficult, as literature on wearable adherence expose inconsistency in reporting and study design.

Overall user satisfaction was high, particularly patients agreed on the ease of use, satisfaction, and improvement in understanding their symptoms. This finding aligns with a study in multiple sclerosis that reported sustained satisfaction with remote monitoring using smartphone and wearable technology over 6 months [Midaglia L, Mulero P, Montalban X, et al. Adherence and satisfaction of smartphone- and smartwatch-based remote active testing and passive monitoring in people with multiple sclerosis: nonrandomized interventional feasibility study. J Med Internet Res. Aug 30, 2019;21(8):e14863. [CrossRef] [Medline]40]. Further qualitative analyses, such as focus groups with patients, could aid in gaining a deeper understanding of the reasons behind these perceptions and to identify areas for improvements. First approaches have been made by the research team within the framework of additional small-scale pilot phases involving patients testing the platform use and workshops for feedback collection and development requests. Furthermore, mixed opinions were indicated by patients regarding whether the use of the telemedicine platform could reduce visits to neurologists or clinics, indicating that the platform may primarily serve as a complement to existing care structures rather than a replacement of personal interactions.

For successful implementation in clinical care, the efficient usage and integration of such data into clinical decision-making processes will be essential. This includes logistical efforts, but also necessitates a careful assessment of data quality and interpretation, and the “appropriate” monitoring intensity for different patient groups (eg, those with a short disease duration, highly active disease, and fast-acting treatment regimens may require more frequent assessments). Furthermore, addressing regulatory challenges, particularly regarding reimbursement structures for health care professionals will be crucial for long-term integration within health care systems.

Limitations

Our study encountered several challenges associated with remote monitoring technology: These included missing passive wearable data primarily due to technical issues and synchronization problems and patients’ discomfort with the wristband from the wearable. Addressing these challenges and providing solutions, such as training sessions and available technical support, is crucial to ensure optimal patient experience and adherence in future studies using these technologies. Furthermore, the study cohort is relatively small, and the study duration is short. Patients with higher digital literacy may have been more likely to participate, potentially impacting the representativeness of the cohort. Regarding user evaluation of health care professionals, it should be noted that the study team size was small and partially comprised members of the development team for the platform, which could add to bias in answering the questionnaire.

Conclusion

In conclusion, our results demonstrate the feasibility of remote monitoring for collecting both subjective (active) and objective (passive) data from multiple sources among patients with MG, as evidenced by above-average adherence rates and acceptability. This underscores the potential for user-friendly digital tools for long-term monitoring of patients with MG and their willingness to track disease progression. Larger and prolonged studies are needed to benchmark our findings and to further explore the effective implementation of such tools and their clinical implications in practice.

Acknowledgments

We thank the Neuroscience Clinical Research Center at Charité Universitätsmedizin Berlin for their support in administration and throughout the formal processes essential for the successful execution of this study. The authors especially wish to thank Maja Olzewska, Josefina Kreusler, and Gabriela Jiron-Lozano for their support in establishing the REDCap database. Furthermore, special acknowledgments are extended to Jens Brestrich and Dike Remstedt for their support in conducting the study. In addition, the authors thank Qurasoft GmbH, namely Lale Zils, for the project assistance during the study and Sebastian Thunert, Lucas Keune, and Ragnar Hirschbrich for their technical support throughout the study. We wish to thank all the patients who participated in the study. Figure 2 was created with BioRender.com. Argenx, UCB, and Hormosan provided a grant to support the study but were not involved in the design of the study. The project was partly funded and supported by the Berlin Institute for Health/Charité Universitätsmedizin Berlin.

Data Availability

The datasets generated or analyzed during this study are available from the corresponding author on reasonable request.

Authors' Contributions

MS wrote the paper. MS, SL, and LG developed the study design. AM critically reviewed the study. MS and SL conducted the study. DL helped with observation of the data. RS performed statistical analyses. MS, SL, and LG interpreted the data. RS, PN, DL, MH, AM, LG, and SL critically reviewed and edited the paper.

Conflicts of Interest

MS has received speaker's honoraria and honoraria for attendance at advisory boards from Argenx and Alexion. MH has received speaker´s honoraria from Argenx and speaker’s honoraria and honoraria for attendance at advisory boards from Alexion. PN has received grant support from PCORI, Alexion, Dianthus, and Janssen. PN has received honoraria for consulting services for Alexion, Argenx, CVS Caremark, Dianthus, GSK, Immune Abs, Janssen, Novartis, and UCB. PN has served on DSMB for Sanofi. AM received speaker's honoraria from Alexion, Grifols, and Hormosan, and honoraria from Argenx, Alexion, MorphoSys, and UCB for consulting services, and financial research support from Alexion and Octapharma. He is chairperson of the medical advisory board of the DMG. SL has received speaker's honoraria for attendance at patient events and advisory boards from Argenx, Alexion, Biogen, Hormosan, Roche, and UCB. None declared by other authors.

  1. Gilhus NE, Tzartos S, Evoli A, Palace J, Burns TM, Verschuuren J. Myasthenia gravis. Nat Rev Dis Primers. May 2, 2019;5(1):1-19. [CrossRef]
  2. Vinciguerra C, Iacono S, Bevilacqua L, et al. Sex differences in neuromuscular disorders. Mech Ageing Dev. Apr 2023;211:111793. [CrossRef] [Medline]
  3. Narayanaswami P, Sanders DB, Wolfe G, et al. International consensus guidance for management of myasthenia gravis: 2020 Update. Neurology (ECronicon). Jan 19, 2021;96(3):114-122. [CrossRef] [Medline]
  4. Lehnerer S, Jacobi J, Schilling R, et al. Burden of disease in myasthenia gravis: taking the patient’s perspective. J Neurol. Jun 2022;269(6):3050-3063. [CrossRef] [Medline]
  5. Stein M, Hoffmann S, Gerischer L, et al. Myasthenia gravis - a retrospective analysis of e-mail inquiries made to a patient organisation and specialized center to uncover unmet needs from patients and caregivers. BMC Neurol. Dec 7, 2022;22(1):455. [CrossRef] [Medline]
  6. Masanneck L, Räuber S, Schroeter CB, et al. Driving time-based identification of gaps in specialised care coverage: An example of neuroinflammatory diseases in Germany. Digit Health. 2023;9:20552076231152989. [CrossRef] [Medline]
  7. Holko M, Litwin TR, Munoz F, et al. Wearable fitness tracker use in federally qualified health center patients: strategies to improve the health of all of us using digital health devices. NPJ Digit Med. Apr 25, 2022;5(1):53. [CrossRef] [Medline]
  8. Ramezani R, Cao M, Earthperson A, Naeim A. Developing a smartwatch-based healthcare application: notes to consider. Sensors (Basel). Jul 25, 2023;23(15):6652. [CrossRef] [Medline]
  9. Dierckx R, Pellicori P, Cleland JGF, Clark AL. Telemonitoring in heart failure: big brother watching over you. Heart Fail Rev. Jan 2015;20(1):107-116. [CrossRef] [Medline]
  10. Koehler F, Koehler K, Deckwart O, et al. Efficacy of telemedical interventional management in patients with heart failure (TIM-HF2): a randomised, controlled, parallel-group, unmasked trial. Lancet. Sep 22, 2018;392(10152):1047-1057. [CrossRef] [Medline]
  11. Smolis-Bąk E, Dąbrowski R, Piotrowicz E, et al. Hospital-based and telemonitoring guided home-based training programs: Effects on exercise tolerance and quality of life in patients with heart failure (NYHA class III) and cardiac resynchronization therapy. A randomized, prospective observation. Int J Cardiol. Nov 2015;199:442-447. [CrossRef]
  12. Zhang Y, Pratap A, Folarin AA, et al. Long-term participant retention and engagement patterns in an app and wearable-based multinational remote digital depression study. NPJ Digit Med. Feb 17, 2023;6(1):25. [CrossRef] [Medline]
  13. Druce KL, Dixon WG, McBeth J. Maximizing engagement in mobile health studies: lessons learned and future directions. Rheum Dis Clin North Am. May 2019;45(2):159-172. [CrossRef] [Medline]
  14. De Angel V, Lewis S, White K, et al. Digital health tools for the passive monitoring of depression: a systematic review of methods. NPJ Digit Med. Jan 11, 2022;5(1):3. [CrossRef] [Medline]
  15. Svennberg E, Tjong F, Goette A, et al. How to use digital devices to detect and manage arrhythmias: an EHRA practical guide. Europace. Jul 15, 2022;24(6):979-1005. [CrossRef] [Medline]
  16. Hillmann HAK, Soltani S, Mueller-Leisse J, Hohmann S, Duncker D. Cardiac rhythm monitoring using wearables for clinical guidance before and after catheter ablation. J Clin Med. Apr 26, 2022;11(9):2428. [CrossRef] [Medline]
  17. Stein M, Meisel A, Moench M, et al. The telemedical platform myalink for remote monitoring in myasthenia gravis: rationale and protocol for a proof of concept study. MedRxiv. Preprint posted online on Jul 11, 2024. [CrossRef]
  18. Jaretzki A 3rd, Barohn RJ, Ernstoff RM, et al. Myasthenia gravis: recommendations for clinical research standards. Task Force of the Medical Scientific Advisory Board of the Myasthenia Gravis Foundation of America. Neurology (ECronicon). Jul 12, 2000;55(1):16-23. [CrossRef] [Medline]
  19. Randomization service for multicenter clinical trials. Randomizer. URL: https://www.randomizer.at/ [Accessed 2025-02-27]
  20. Barohn RJ, McIntire D, Herbelin L, Wolfe GI, Nations S, Bryan WW. Reliability testing of the quantitative myasthenia gravis score. Ann N Y Acad Sci. May 13, 1998;841:769-772. [CrossRef] [Medline]
  21. Wolfe GI, Herbelin L, Nations SP, Foster B, Bryan WW, Barohn RJ. Myasthenia gravis activities of daily living profile. Neurology (ECronicon). Apr 22, 1999;52(7):1487-1489. [CrossRef] [Medline]
  22. Burns TM, Sadjadi R, Utsugisawa K, et al. International clinimetric evaluation of the MG-QOL15, resulting in slight revision and subsequent validation of the MG-QOL15r. Muscle Nerve. Dec 2016;54(6):1015-1022. [CrossRef] [Medline]
  23. Abraham A, Breiner A, Barnett C, Katzberg HD, Bril V. The utility of a single simple question in the evaluation of patients with myasthenia gravis. Muscle Nerve. Feb 2018;57(2):240-244. [CrossRef] [Medline]
  24. Kukulka K, Gummi RR, Govindarajan R. A telephonic single breath count test for screening of exacerbations of myasthenia gravis: A pilot study. Muscle Nerve. Aug 2020;62(2):258-261. [CrossRef] [Medline]
  25. Spitzer RL, Kroenke K, Williams JB. Validation and utility of a self-report version of PRIME-MD: the PHQ primary care study. Primary care evaluation of mental disorders. Patient health questionnaire. JAMA. Nov 10, 1999;282(18):1737-1744. [CrossRef] [Medline]
  26. Zigmond AS, Snaith RP. The hospital anxiety and depression scale. Acta Psychiatr Scand. Jun 1983;67(6):361-370. [CrossRef] [Medline]
  27. Mendoza M, Tran C, Bril V, Katzberg HD, Barnett C. Patient-acceptable symptom states in myasthenia gravis. Neurology (ECronicon). Sep 22, 2020;95(12):e1617-e1628. [CrossRef] [Medline]
  28. Brooke J. SUS: A quick and dirty usability scale. In: Usability Evaluation in Industry. Taylor & Francis; 1995:189-194.
  29. Braun M, Schmidt O, Schultz T, Woehrle H, Sundrup MG, Schöbel C. Erfahrungen mit der digitalen Versorgung von Patienten mit chronischen und akuten Lungenerkrankungen während der SARS-CoV-2-Pandemie [Article in German]. Internist. Mar 2022;63(3):255-265. [CrossRef]
  30. R. The R Project for Statistical Computing. URL: https://www.r-project.org/ [Accessed 2020-09-11]
  31. Bangor A, Kortum PT, Miller JT. An empirical evaluation of the System Usability Scale. Int J Hum Comput Interact. Jul 29, 2008;24(6):574-594. [CrossRef]
  32. Wahle F, Kowatsch T, Fleisch E, Rufer M, Weidt S. Mobile sensing and support for people With depression: a pilot trial in the wild. JMIR Mhealth Uhealth. Sep 21, 2016;4(3):e111. [CrossRef] [Medline]
  33. Jacoby SF, Robinson AJ, Webster JL, Morrison CN, Richmond TS. The feasibility and acceptability of mobile health monitoring for real-time assessment of traumatic injury outcomes. Mhealth. 2021;7:5. [CrossRef] [Medline]
  34. Lee S, Kim H, Park MJ, Jeon HJ. Current advances in wearable devices and their sensors in patients with depression. Front Psychiatry. 2021;12:672347. [CrossRef] [Medline]
  35. Chan YFY, Wang P, Rogers L, et al. The Asthma Mobile Health Study, a large-scale clinical observational study using ResearchKit. Nat Biotechnol. Apr 2017;35(4):354-362. [CrossRef] [Medline]
  36. Pavic M, Klaas V, Theile G, et al. Mobile health technologies for continuous monitoring of cancer patients in palliative care aiming to predict health status deterioration: a feasibility study. J Palliat Med. May 2020;23(5):678-685. [CrossRef] [Medline]
  37. Pedrelli P, Fedor S, Ghandeharioun A, et al. Monitoring changes in depression severity using wearable and mobiles ensors. Front Psychiatry. 2020;11:584711. [CrossRef] [Medline]
  38. Werhahn SM, Dathe H, Rottmann T, et al. Designing meaningful outcome parameters using mobile technology: a new mobile application for telemonitoring of patients with heart failure. ESC Heart Fail. Jun 2019;6(3):516-525. [CrossRef] [Medline]
  39. Wu JM, Ho TW, Chang YT, et al. Wearable-based mobile health app in gastric cancer patients for postoperative physical activity monitoring: focus group study. JMIR Mhealth Uhealth. Apr 23, 2019;7(4):e11989. [CrossRef] [Medline]
  40. Midaglia L, Mulero P, Montalban X, et al. Adherence and satisfaction of smartphone- and smartwatch-based remote active testing and passive monitoring in people with multiple sclerosis: nonrandomized interventional feasibility study. J Med Internet Res. Aug 30, 2019;21(8):e14863. [CrossRef] [Medline]
  41. Matcham F, Leightley D, Siddi S, et al. Remote Assessment of Disease and Relapse in Major Depressive Disorder (RADAR-MDD): recruitment, retention, and data availability in a longitudinal remote measurement study. BMC Psychiatry. Feb 21, 2022;22(1):136. [CrossRef] [Medline]
  42. Sohn A, Speier W, Lan E, et al. Integrating remote monitoring into heart failure patients’ care regimen: A pilot study. PLoS One. 2020;15(11):e0242210. [CrossRef] [Medline]
  43. Naslund JA, Aschbrenner KA, Bartels SJ. Wearable devices and smartphones for activity tracking among people with serious mental illness. Ment Health Phys Act. Mar 2016;10:10-17. [CrossRef] [Medline]


BlnDSG: Berlin Data Protection Act
CFS: Chalder Fatigue Scale
GPDR: General Data Protection Regulation
HADS: Hospital Anxiety and Depression Scale
MG: myasthenia gravis
MG-ADL: myasthenia gravis activities of daily living
MG-QoL15r: myasthenia gravis quality of life, revised
MGFA: Myasthenia Gravis Foundation of America
PASS: Patient Acceptable Symptom State
PROMs: patient-reported outcome measures
QMGS: quantitative myasthenia gravis score
RCT: randomized controlled trial
REDCap: Research Electronic Data Capture
SSQ: single simple question
SUS: System Usability Scale


Edited by Amaryllis Mavragani; submitted 03.04.24; peer-reviewed by Claudia Vinciguerra, Lars Masanneck; final revised version received 03.12.24; accepted 27.12.24; published 03.03.25.

Copyright

© Maike Stein, Regina Stegherr, Pushpa Narayanaswami, David Legg, Meret Herdick, Andreas Meisel, Lea Gerischer, Sophie Lehnerer. Originally published in JMIR Formative Research (https://formative.jmir.org), 3.3.2025.

This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included.