Original Paper
Abstract
Background: Individuals are exposed to a variety of indoor residential toxins including volatile organic compounds and particulates. In adults with asthma, such exposures are associated with asthma symptoms, asthma exacerbations, and decreased lung function. However, data on these exposures and asthma-related outcomes are generally collected at different times and not in real time. The integration of multiple platforms to collect real-time data on environmental exposure, asthma symptoms, and lung function has rarely been explored.
Objective: This paper describes how adults with asthma perceive the acceptability and usability of three integrated devices: (1) residential indoor air quality monitor, (2) ecological momentary assessment (EMA) surveys delivered via a smartphone app, and (3) home spirometry, over 14 days.
Methods: Participants (N=40) with uncontrolled asthma were mailed the Awair Omni indoor air quality monitor, ZEPHYRx home spirometer, and detailed instructions required for the in-home monitoring. The air quality monitor, spirometer, and EMA app were set up and tested during a videoconference or phone orientation with a research team member. Midway through the 14-day data collection period, participants completed an interview about the acceptability of the study devices or apps, instructional materials provided, and the setup process. At the end of the 14-day data collection period, participants completed a modified System Usability Scale. A random sample of 20 participants also completed a phone interview regarding the acceptability of the study and the impact of the study on their asthma.
Results: Participants ranged in age from 26 to 77 (mean 45, SD 13.5) years and were primarily female (n=36, 90%), White (n=26, 67%), college graduates (n=25, 66%), and residing in a single-family home (n=30, 75%). Most indicated that the air quality monitor (n=23, 58%), the EMA (n=20, 50%), and the spirometer (n=17, 43%) were easy to set up and use. Challenges with the EMA included repetitive surveys, surveys arriving during the night, and technical issues. While the home spirometer was identified as a plausible means to evaluate lung function in real time, the interpretation of the readings was unclear, and several participants reported side effects from home spirometer use. Overall, the acceptability of the study and the System Usability Scale scores were high.
Conclusions: The study devices were highly acceptable and usable. Participant feedback was instrumental in identifying technical challenges that should be addressed in future studies.
doi:10.2196/60147
Keywords
Introduction
Individuals are exposed to indoor residential toxins including volatile organic compounds (VOCs) and particulates [
]. Common indoor sources of VOCs include cleaning or disinfecting products, personal care products, air fresheners, fragrances, and pesticides [ - ]. Residential sources of particulates include vacuum cleaning, cooking, tobacco smoke, wood-burning fireplaces, dust, candles, and animal dander [ - ]. While indoor residential exposure to VOCs and particulates has been associated with asthma symptoms, data on asthma exacerbations, lung function, indoor VOCs and fine particulates, and pulmonary or asthma symptoms are generally collected at different times, or researchers rely solely on electronic health records or survey data [ , - ]. The collection of real-time data on environmental exposures, asthma symptoms, and lung function has rarely been explored. In their 2020 study, Turner et al [ ] had adolescents wear personal ultrafine particulate monitors for 3 hours per day for 7 days. In addition, participants completed home spirometry 5 times per day and ecological momentary assessment (EMA) surveys on a smartphone to determine respiratory symptoms throughout the day. While it was possible for Turner et al [ ] to retrospectively assess associations between lung function and exposures within 30 minutes, real-time determination of exposure and its pulmonary impact was not possible.We designed a feasibility study to capture residential indoor air quality in real time and thus examine the real-time impact of residential indoor air quality on asthma symptoms and lung function in a sample of adults with uncontrolled asthma [
]. A primary purpose of the feasibility study was to determine the acceptability and usability of (1) real-time residential indoor air quality monitoring along with EMA to evaluate asthma symptoms in response to poor residential air quality and (2) using home spirometry to monitor lung function in this population.Although the technology for low-cost, residential, consumer-grade, continuous indoor air quality monitors has evolved [
- ] and user-friendly sensors are often advocated for indoor residential use [ ], few studies to date have evaluated the acceptability and usability of these sensors from the user’s perspective to further understand the implementation potential. Moore et al [ ] used 3 Dylos air quality monitors to assess levels of particulates 2.5 microns or less in diameter (PM2.5) in 6 homes with SMS text messages delivered when a spike in the PM2.5 levels occurred. A tablet visualization interface allowed for viewing data trends across time. Participants indicated they appreciated knowing about the indoor air quality in various rooms, how their air quality changed over time, and how activities such as cooking impacted their home indoor environment. However, engagement over time (up to 40 weeks) decreased.Home-based spirometry provides a means for obtaining timely information regarding lung function remotely, thus facilitating self-management and minimizing the need for clinic or hospital visits [
]. Acceptability and usefulness of home spirometry for individuals with chronic obstructive pulmonary disease, interstitial lung disease, cystic fibrosis, and asthma were found to be high, with most indicating the device was easy to use, easy to set up, cost-effective, empowering, and convenient [ - ]. While motivation to exercise to improve lung function readings was also noted as a benefit by adults with cystic fibrosis, a concern raised during interviews was distrust of technology [ ].EMA has been used in a variety of studies including those addressing mental health, substance abuse, diet, weight loss, smoking, well-being, pain, eating disorders, physical activity, sleep, fatigue, and asthma [
- ]. Participants in these studies reported strengths of EMA surveys including ease of use, simplicity, fun to use, a graphic user interface that includes easy-to-follow prompts, survey items that increase awareness of personal behaviors, and reminders to respond to prompts and complete certain behaviors such as taking medication [ ]. Identified weaknesses of EMA include too many surveys, tediousness, technical issues, repetitiveness, lack of customization, unclear survey items, questionable timing of surveys, easily missed surveys, lack of technological features such as text-to-speech capability, and the length of some surveys [ , - ].Acceptability and usability of home spirometry, EMA, and residential indoor air quality monitors are generally high. However, evidence is lacking on the acceptability and usability of these devices or apps when used simultaneously by adults with asthma. The purpose of this paper is to describe how adults with asthma perceive the acceptability and usability of three integrated devices: (1) residential indoor air quality monitor, (2) EMA delivered via smartphones, and (3) home spirometry, over 14 days.
Methods
Study Design
Participants were recruited from a pool of adults with asthma who previously completed a survey concerning the COVID-19 pandemic [
], who indicated they were interested in future research opportunities, and who reported that they used disinfectants or cleaning products at least 5 times per week. Inclusion criteria for this study were adults 18 years old or older who own a smartphone, have a Wi-Fi or wireless internet connection in their home, and have uncontrolled asthma (Asthma Control Test <20 or asthma exacerbation in the past year). The protocol for this study has been previously published [ ]. A total of 40 participants completed the 2-week, in-home study between April 2022 and March 2023. Participants were mailed the indoor air quality monitor, home spirometer, and detailed instructions for in-home testing. Prior to the start of the study, instructions to deploy each device (air quality monitor, spirometer, and EMA app) were developed with input from a community advisory board (CAB). The CAB recommended that the instructions for each device include detailed step-by-step directions and clear pictures of the setup. For example, based on recommendations from the CAB, we added screenshots of the spirometer app setup screen with added text explaining what and where information was needed. The CAB was compensated for providing feedback to the research team.A live, one-on-one orientation session with a research team member via videoconference or phone was completed, during which instructions for the study were reviewed and the air quality monitor, spirometer and app, and the EMA app were set up and tested (
). Orientation sessions averaged 1 hour. Participants then completed a 3-day, run-in period to become familiar with the apps and equipment and to ensure data from each device were transmitted to its corresponding dashboard. Following the 3-day, run-in period, participants completed the 14-day data collection period. The research team monitored all data transmitted to the dashboards throughout the run-in and data collection periods and conducted troubleshooting as necessary when problems were identified (ie, Wi-Fi connectivity issues, needing to log back into the EMA or spirometry app).Midway through the 14-day data collection period, participants completed a 7-day interview and were asked about the acceptability of the air quality monitor, spirometer, and EMA. Participants were also queried regarding the instructional materials provided, the orientation to the study, and the setup process. Usability of the study devices was assessed using a modified System Usability Scale (SUS) [
]. All participants were emailed a link to the modified SUS on REDCap (Research Electronic Data Capture; Vanderbilt University) at the end of the 14-day data collection period. In addition, a random sample of 20 participants was selected to complete a phone interview. In the phone interview, participants were again queried about the acceptability of the study devices, the overall study, the impact of the study on their asthma, and suggestions for improving the study. The 7 and 14-day interviews were recorded.Ethical Considerations
The study was approved by the institutional review boards at the University of Kansas Medical Center (00145830), the University of Louisville (21.0466), the University of Illinois Chicago (2020-0851), and the University of Chicago (22-0767) prior to the conduct of the study. Participants provided e-consent for the study prior to completing the REDCap baseline survey. Data were deidentified prior to analysis. Participants kept the spirometer as an incentive (US $125 value).
Study Devices
The commercially available Awair Omni indoor air quality monitor measured total VOCs (TVOCs) and PM2.5 in participants’ home environments. The air quality monitor plugs into a standard electrical outlet, has an 8-hour internal battery backup, and is Wi-Fi enabled (
). Participants were instructed to place the air quality monitor in the room where they spend most of their time at home. Specifically, participants were asked to place the air quality monitor in a central location, 3 to 6 feet off the ground, and as far as possible from a window or door. Participants were also asked to move the monitor into the room where they slept at night.The ZEPHYRx Spirometer system includes a handheld Bluetooth spirometer (MIR Spirobank Smart) and a mobile app (
). The research team developed the instruction guide and provided step-by-step information on how to use and care for the spirometer. Participants were encouraged to use the nose clip included with their spirometer when they were completing pulmonary function testing. A trained research team member initially coached each participant through the spirometry procedures. Participants were asked to use their spirometer each morning and when prompted by an EMA survey triggered by elevated TVOC or PM2.5 levels detected by the air quality monitor.The PiLR EMA (MEI Research) app was used to gather real-time data regarding residential air quality events and real-time asthma symptoms. Participants received EMA surveys on their smartphones each morning, randomly twice each day, and when elevated TVOC or PM2.5 levels were detected by the air quality monitor (
). Specifically, each morning participants received an EMA survey concerning nighttime asthma symptoms; the survey included a reminder to use their spirometer. EMA surveys addressing the use of cleaners, disinfectants, or hand sanitizers in the home during the previous 2 hours along with current asthma symptoms occurred randomly twice each day between 6 AM and 10 PM. Finally, to detect real-time TVOC or PM2.5 residential exposure and concomitant asthma symptoms, the publicly available application programming interface of the Awair Omni air quality monitor was used to develop the EMA software that enabled an EMA survey to be sent to the participant immediately at specific target points. An EMA survey was sent when levels of indoor residential TVOCs or PM2.5 were detected above a specific threshold level—TVOCs ≥333 ppb and PM2.5 ≥15 µg/m3. The EMA survey noted that the participant’s air quality monitor detected an air quality change in their residence. Participants were initially asked whether they were home. For those indicating they were at home, a drop-down list of possible sources for the air quality change was presented (eg, disinfectant use, cooking, pets, and burning candles). Participants were asked to identify the potential sources of the air quality change from a list of 18 options (eg, disinfectant, perfume, and cooking) that included “I don’t know” and an open-ended other option. In addition, participants could take a picture of the potential source of the air quality change and upload it to the EMA survey. The EMA survey also asked participants to indicate if they were currently having any asthma symptoms. Participants were prompted to use their spirometer at that time as well.Instruments
Demographic data such as age, sex, race, education, employment status, and residence were collected at baseline using REDCap. The modified SUS [
- ] included 3 subscales, the air quality monitor SUS, the spirometer SUS, and the EMA SUS, to specifically capture the usability of each device or app (eg, I thought the Awair air quality monitor was easy to use). Modifications to the original 10-item SUS included specifying the time frame as “over the last two weeks” and querying if each device was well integrated into the study. The air quality and the EMA SUS subscales each had 11 items with the 1 additional item asking if the participant would recommend that device to others with asthma. The SUS EMA included 13 items; participants were also asked if they found the EMA surveys unnecessarily repetitive, time-consuming, and arriving at an inconvenient time. One additional item was added at the end of the survey that addressed the overall integration of the various study components. Response options ranged from 1= strongly agree to 5= strongly disagree for all survey items. An open-ended item at the end of each subscale allowed participants to write comments regarding what they liked or disliked about each study device.Data Management and Analysis
Quantitative data were downloaded from REDCap into SPSS Statistics (IBM) [
]. Demographic data were analyzed using descriptive statistics. A composite SUS score for each subscale was calculated using the method described by Brooke [ ]. To create SUS subscale scores, individual items were recoded to a 0-4 scale with higher values being more positive and summed to create scale scores. Negatively worded items were reverse-coded. Raw summed scores for the air quality monitor and spirometer subscales (11 items each) were multiplied by a multiplier of 2.27 to convert to a 0 to 100 scale; the EMA subscale (13 items) raw summed score was multiplied by a multiplier of 1.92 to convert to a 0 to 100 scale; and the overall SUS item score addressing integration of study components was multiplied by a factor of 25.Open-ended responses to SUS items were downloaded into Dedoose software (SocioCultural Research Consultants). Participants’ 7 and 14-day interviews were transcribed, validated for accuracy, and added to Dedoose. Themes related to the acceptability and usability of each of the devices were determined based on written responses to open-ended SUS items and the transcripts from the 7 and 14-day interviews and validated independently by 2 research team members.
Results
Overview
Participants (N=40) were primarily female (n=36, 90%), college graduates (n=25, 66%), employed (n=30, 75%), owners of their home (n=27, 67.5%), and residing in a single-family home (n=30, 75%), and they were from 18 (36%) different US states. Most participants indicated they were non-Hispanic (n=38, 95%) and White (n=26, 67%). A total of 5 (13%) participants indicated Black or African American race, 4 (10%) reported their race as American Indian or Alaskan Native, and 2 (5%) indicated Asian race. Participants ranged in age from 26 to 77 (mean 45, SD 13.5) years.
Indoor Air Quality Monitor
Study participants reported that the indoor air quality monitor was easy to use (n=23, 58%) and educational (n=6, 15%), with 1 (3%) participant commenting that they “started noticing trends that set off the air quality change surveys” (
). The real-time reporting of air quality results was also mentioned by several participants (n=6, 15%) as a benefit of the monitor. A total of 4 (10%) participants described confusion at times when the air quality monitor indicated an elevated measurement, but they could not identify the source of the air quality change or what the alerts meant. Three (8%) participants reported that the device “was very sensitive” or “goes off a lot.” Two (5%) participants noted that the brightness from the light on the front display of the air quality monitor was an issue at night while trying to sleep. In addition, several technical issues were reported by 7 (18%) participants, including trouble connecting the device to their home Wi-Fi system, difficulties connecting the power cord, and needing to have the device continuously plugged into an outlet.Indoor air quality monitor themes | Indoor air quality monitor quotes |
Easy to use |
|
Real-time results |
|
Educational |
|
Notification timing |
|
Clarity of results |
|
Technical issues |
|
Bright display at night |
|
EMA App
A total of 20 (50%) participants indicated that the EMA was easy to set up and use, fast, functional, and reliable in that it “worked the way it’s intended” (
). Participants identified several challenges to using the EMA including technical issues and survey timing. Technical issues included app malfunctions (n=2, 5%), notifications without any clear air quality triggers (n=5, 13%), duplicate notifications (n=15, 38%), frequent need to sync the app (n=4, 10%), and surveys that continued asking about trigger events when the participant had indicated they were not home (n=5, 13%). The timing of EMA survey notifications was another identified challenge. In total, 8 (20%) participants stated that they received surveys at inconvenient times including during the night. Two (5%) participants noted they received surveys in the morning while they were still sleeping. Seven (35%) participants indicated they were unable to determine the source of the environmental exposure that triggered the EMA survey. Other EMA challenges included confusion regarding the survey questions’ skip logic (n=2, 5%) and the lack of open-ended options to provide a more thorough response to a survey trigger (n=2, 5%).EMAa themes | EMA quotes |
Easy to use |
|
Notification timing |
|
Survey ambiguity and confusion |
|
Technical issues |
|
aEMA: ecological momentary assessment.
Home Spirometer
Overall, participants indicated that setting up the home spirometer was easy (n=17, 43%) and the device was easy to use (n=13, 33%;
). Two (5%) participants noted that they liked the size and portability of the spirometer. Eight (20%) liked getting the real-time results of their lung function. Participants also identified challenges to using the spirometer. Thirty (75%) participants found the spirometer challenging to use for many reasons including the spirometer required too many breathing efforts, the instructions were tedious, and the spirometer did not register an effort correctly. Seven (18%) participants wanted more information on how to interpret the breathing test results. Well-documented side effects reported from 9 (23%) participants about spirometry assessments included lightheadedness and shortness of breath. Other comments included issues with a low battery (n=2, 5%), general dislike of using the device (n=2, 5%), and lack of clarity in the ZEPHYRx app instructions regarding when they were to use the spirometer (n=4, 10%).Spirometer themes | Spirometer quotes |
Easy to use |
|
Real-time results |
|
Challenging to use |
|
Clarity of results |
|
Adherence |
|
Side effects |
|
Overall Study
A total of 11 (28%) of the 40 participants indicated that the study was easy. Others noted that the study was interesting (n=18, 45%), educational (n=8, 20%), and useful for planned or already implemented behavior changes (n=5, 13%). Five (13%) participants reported an increased awareness of their indoor air quality and its relationship to their asthma symptoms. Those same 5 participants stated they had either made plans to implement or had already implemented behavior changes such as discontinuing or limiting the use of candles (n=1, 3%), using smaller amounts of certain products (n=2, 5%), and taking new actions when noticing their indoor air quality was poor (eg, opening a window to increase ventilation; n=1, 3%). Four (10%) participants did not notice an impact on their asthma symptoms or severity. Others said the study helped them take their medication daily (n=1, 3%) or hold their breath longer (n=1, 3%), and that it had generally improved their asthma symptoms (n=4, 10%). In total 10 of the 40 (25%) participants also stated that the components of the study worked seamlessly together and 16 (40%) indicated that the research staff were nice and helpful. Several participants noted that overall, the study worked well (n=7, 18%), was “cool” or “fun” (n=4, 10%), and was well thought out (n=3, 8%;
).Overall study themes | Overall study sample quotes |
Increased awareness |
|
Behavior changes |
|
Educational |
|
Study implementation |
|
Asthma impacts |
|
Anticipation of study results |
|
Recommendations |
|
SUS Scores
A total of 37 (92.5%) participants completed the modified SUS after the 14-day data collection period. The average scores for all of the subscales, as well as the item addressing overall integration of study devices, were above a 68 cut point, denoted by Lewis and Sauro [
], and thus are considered above average usability. A curved grading scale described by Lewis and Sauro [ ] indicates that all of the subscales were graded at B or above with an A– grade for the overall integration of the 3 assessed devices ( ).Modified SUS subscale | Score, mean (SD) | Gradeb |
Home spirometer | 75.9 (20.5) | B |
Air Quality Monitor | 83.9 (14.9) | B+ |
Ecological momentary assessment | 74.8 (17.8) | B |
Overall integration of devices | 87.2 (20.9) | A– |
aSUS: System Usability Scale.
b84.1-100=A+; 80.8-84.0=A; 78.9-80.7=A–; 77.2-78.8=B+; and 74.1-77.1=B [
].Discussion
Principal Findings
This study aimed to evaluate the acceptability and usability of 3 devices used simultaneously in a feasibility study exploring real-time residential TVOC and PM2.5 exposures and real-time asthma symptoms, as well as lung function in adults with uncontrolled asthma. The initial development of the study included an intensive, iterative testing period while integrating the technologies used for the study. The research team spent more than a year testing the equipment and apps in trials to ensure participants would have a positive experience. Each modification made by the research team, in addition to mandatory app software updates, required an additional testing period to verify that all devices were working properly, step-by-step instructions were clearly and accurately written, and participant burden was minimized.
The integrated devices consisted of the Awair Omni indoor air quality monitor, the ZEPHYRx home spirometer, and PiLR EMA app. A 3-day, run-in period was an integral component of the study that allowed the participant to acclimate to the study devices and EMA surveys and allowed the research team to monitor for any problems prior to the 14-day data collection period. Two types of problems were identified—Wi-Fi connectivity and participants inadvertently logging out of the EMA and spirometer app. We were able to address the Wi-Fi connectivity issues on an individual basis. We added information to our orientation sessions informing participants not to log out of the EMA and spirometry app.
Participants were asked to keep their air quality monitor in the room they occupied the most in their home and to move it to their sleeping room at night. All participants received a minimum of 3 EMA surveys per day, including 1 morning and 2 random surveys. The morning survey addressed nighttime asthma symptoms (if present), and the random surveys queried about residential exposures, as well as asthma symptoms during the day. Additional EMA surveys occurred when elevated residential TVOCs or PM2.5 triggered an EMA survey in which participants were asked to use their spirometer.
The acceptability of both the devices and the study procedures was positively conveyed by participants based on the 7 and 14-day interviews and responses to the open-ended SUS items. The indoor air quality monitor was considered acceptable given the positive comments regarding the ease of use, educational capabilities, and reporting of air quality findings. While some technical issues were noted by participants, these were addressed by the research team when identified. Our participants indicated that the EMA was easy to use, fast, and reliable, which is similar to findings from Nichols et al [
]. Common weaknesses of the EMA were also identified by our participants including technical issues, as well as concerns with survey timing or too many surveys [ , - ]. In addition, our participants noted that the EMA survey would continue to query about residential exposures even when they responded that they were not at home. While the team tested this aspect of the EMA survey extensively, we found additional coding issues were due to updates in the operating systems of smartphones or application software.Participants voiced mixed responses to the acceptability of the home spirometer. Similar to other studies, many participants reported that the setup of the spirometer was easy, the device was easy to use, and having real-time lung function results was positively viewed [
- ]. However, some participants voiced several challenges to using the spirometer including tediousness, difficulty with the breathing tests, and physiologic side effects, such as lightheadedness and shortness of breath. During the study, research staff noted that some participants were making 6 or more assessment attempts (consisting of deep breaths) to obtain a reading that was “acceptable” according to the spirometer. We then revised our orientation instructions to indicate that no more than 3 deep breaths should be attempted, irrespective of whether a reading was deemed acceptable. Given the issues with the spirometer, we recommend that a peak flow meter be considered as an objective measure of lung function in future work.When asked about the overall study acceptability, participants provided positive feedback. Several noted that it was educational and had provided the impetus for them to initiate behavioral changes such as limiting the use of candles and potentially toxic products. While several participants stated that they felt participation in the study improved their asthma symptoms, others noted no impact on their asthma. Other studies [
] have reported less than 10% of those with asthma experienced immediate symptoms after an air quality event exposure. Similar to the app developed by Kim et al [ ] for children, future research should expand the focus to include an app for adults with asthma to know, in real time, the indoor and outdoor air quality that may be impacting their asthma symptoms and promote mitigation behaviors and address their asthma symptoms. Future studies may also include an app that in real time examines exhaled breath as a biomarker of VOC exposure [ , ].Limitations
Our study had several limitations. Our sample was relatively small (N=40) and participants were primarily women, well-educated, and homeowners. As previously noted, smartphone and application operating system updates were a challenge. Further, the in-app spirometer onboarding instructions were modified by the company without notification. When these updates occurred, study staff had to quickly identify any discrepancies in the orientation materials and modify instruction sheets as needed. An additional study limitation was the inclusion requirement that participants have Wi-Fi access in their homes. Future studies should provide a mobile hotspot when Wi-Fi is not available. Finally, given the challenges with the spirometer, the validity of these data is of concern for those individuals who were unable to provide repeatable measures.
Conclusions
This pilot study used a sample from 18 states to assess the acceptability and usability of the Awair Omni indoor air quality monitor, the ZEPHYRx home spirometer, and PiLR EMA app in determining real-time residential air quality environmental exposures, concomitant with real-time asthma symptoms and lung function, in adults with uncontrolled asthma. Participants found all study devices easy to set up and use. Concerns were raised related to the side effects of spirometry assessment and the receptiveness or technical issues of the EMA surveys. Based on the modified SUS, usability was determined to be acceptable for all study devices, as well as the overall study. Recommendations for future studies include increasing the sample size and diversity of participants and expanding troubleshooting efforts to ensure minimal disruptions to the data collection process.
Acknowledgments
This research was supported by the National Institute of Environmental Health Sciences (NIEHS) of the National Institutes of Health (NIH; R21ES033118 and P30 ES030283). The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH. Generative artificial intelligence was not used in any portion of the paper writing.
Data Availability
The data sets and analyzed during this study are available from the corresponding author on reasonable request and contingent on Institutional Review Board approval.
Conflicts of Interest
None declared.
References
- Maung TZ, Bishop JE, Holt E, Turner AM, Pfrang C. Indoor air pollution and the health of vulnerable groups: a systematic review focused on particulate matter (PM), volatile organic compounds (VOCs) and their effects on children and people with pre-existing lung disease. Int J Environ Res Public Health. 2022;19(14):8752. [FREE Full text] [CrossRef] [Medline]
- Halios CH, Landeg-Cox C, Lowther SD, Middleton A, Marczylo T, Dimitroulopoulou S. Chemicals in European residences - part I: a review of emissions, concentrations and health effects of volatile organic compounds (VOCs). Sci Total Environ. Sep 15, 2022;839:156201. [FREE Full text] [CrossRef] [Medline]
- Soni V, Singh P, Shree V, Goel V. Effects of VOCs on human health. In: Sharma N, Agarwal A, Eastwood P, Gupta T, Singh A, editors. Air Pollution and Control. Singapore. Springer; 2018:119-142.
- Vardoulakis S, Giagloglou E, Steinle S, Davis A, Sleeuwenhoek A, Galea KS, et al. Indoor exposure to selected air pollutants in the home environment: a systematic review. Int J Environ Res Public Health. 2020;17(23):8972. [FREE Full text] [CrossRef] [Medline]
- Karottki DG, Bekö G, Clausen G, Madsen AM, Andersen ZJ, Massling A, et al. Cardiovascular and lung function in relation to outdoor and indoor exposure to fine and ultrafine particulate matter in middle-aged subjects. Environ Int. 2014;73:372-381. [FREE Full text] [CrossRef] [Medline]
- National Academies of Sciences, Engineering, and Medicine, Health and Medicine Division, Board on Population Health and Public Health Practice, Butler DA, Madhavan G, Alper J, et al. Rapporteurs. Health Risks of Indoor Exposure to Particulate Matter: Workshop Summary. Washington, DC. National Academies Press; 2016.
- Rohr AC, Habre R, Godbold J, Moshier E, Schachter N, Kattan M, et al. Asthma exacerbation is associated with particulate matter source factors in children in New York City. Air Qual Atmos Health. 2014;7(2):239-250. [CrossRef]
- Cakmak S, Dales RE, Liu L, Kauri LM, Lemieux CL, Hebbern C, et al. Residential exposure to volatile organic compounds and lung function: results from a population-based cross-sectional survey. Environ Pollut. 2014;194:145-151. [FREE Full text] [CrossRef] [Medline]
- Billionnet C, Gay E, Kirchner S, Leynaert B, Annesi-Maesano I. Quantitative assessments of indoor air pollution and respiratory health in a population-based sample of French dwellings. Environ Res. 2011;111(3):425-434. [CrossRef] [Medline]
- Paterson CA, Sharpe RA, Taylor T, Morrissey K. Indoor PM2.5, VOCs and asthma outcomes: a systematic review in adults and their home environments. Environ Res. 2021;202:111631. [FREE Full text] [CrossRef] [Medline]
- Dales RE, Cakmak S. Is residential ambient air limonene associated with asthma? Findings from the Canadian health measures survey. Environ Pollut. 2019;244:966-970. [CrossRef] [Medline]
- Turner AL, Brokamp C, Wolfe C, Reponen T, Ryan PH. Impact of personal, subhourly exposure to ultrafine particles on respiratory health in adolescents with asthma. Ann Am Thorac Soc. 2022;19(9):1516-1524. [FREE Full text] [CrossRef] [Medline]
- Nyenhuis S, Cramer E, Grande M, Huntington-Moskos L, Krueger K, Bimbi O, et al. Utilizing real-time technology to assess the impact of home environmental exposures on asthma symptoms: protocol for an observational pilot study. JMIR Res Protoc. 2022;11(8):e39887. [FREE Full text] [CrossRef] [Medline]
- Kumar P, Skouloudis AN, Bell M, Viana M, Carotta MC, Biskos G, et al. Real-time sensors for indoor air monitoring and challenges ahead in deploying them to urban buildings. Sci Total Environ. 2016;560-561:150-159. [CrossRef] [Medline]
- Wang J, Du W, Lei Y, Chen Y, Wang Z, Mao K, et al. Quantifying the dynamic characteristics of indoor air pollution using real-time sensors: current status and future implication. Environ Int. 2023;175:107934. [FREE Full text] [CrossRef] [Medline]
- Demanega I, Mujan I, Singer BC, Anđelković AS, Babich F, Licina D. Performance assessment of low-cost environmental monitors and single sensors under variable indoor air quality and thermal conditions. Build Environ. 2021;187:107415. [CrossRef]
- Walker I, Woody D, Singer B. Are low-cost sensors good enough for IAQ controls? REHVA J. 2019;1:6-12. [FREE Full text]
- Izmailova ES, Kilian R, Bakker JP, Evans S, Scotina AD, Reiss TF, et al. Study protocol: a comparison of mobile and clinic-based spirometry for capturing the treatment effect in moderate asthma. Clin Transl Sci. 2023;16(11):2112-2122. [FREE Full text] [CrossRef] [Medline]
- Moore J, Goffin P, Meyer M, Lundrigan P, Patwari N, Sward K, et al. Managing in-home environments through sensing, annotating, and visualizing air quality data. Proc ACM Interact Mob Wearable Ubiquitous Technol. 2018;2(3):1-28. [CrossRef]
- Althobiani MA, Ranjan Y, Jacob J, Orini M, Dobson RJB, Porter JC, et al. Evaluating a remote monitoring program for respiratory diseases: prospective observational study. JMIR Form Res. 2023;7:e51507. [FREE Full text] [CrossRef] [Medline]
- Boente RD, Schacht S, Borton R, Vincent J, Golzarri-Arroyo L, Rattray N. Assessing the acceptability and feasibility of remote spirometric monitoring for rural patients with interstitial lung disease: a multimethod approach. Respir Res. 2024;25(1):92. [FREE Full text] [CrossRef] [Medline]
- Davis J, Ryan M, Marchetti P, Dahlberg SE, Greenberg J, Bacon C, et al. Real-world feasibility of short-term, unsupervised home spirometry in CF. Pediatr Pulmonol. 2022;57(12):3129-3135. [CrossRef] [Medline]
- Kupczyk M, Hofman A, Kołtowski Ł, Kuna P, Łukaszyk M, Buczyłko K, et al. Home self-monitoring in patients with asthma using a mobile spirometry system. J Asthma. 2021;58(4):505-511. [CrossRef] [Medline]
- Dao KP, de Cocker K, Tong HL, Kocaballi AB, Chow C, Laranjo L. Smartphone-delivered ecological momentary interventions based on ecological momentary assessments to promote health behaviors: systematic review and adapted checklist for reporting ecological momentary assessment and intervention studies. JMIR Mhealth Uhealth. 2021;9(11):e22890. [FREE Full text] [CrossRef] [Medline]
- de Vries LP, Baselmans BML, Bartels M. Smartphone-based ecological momentary assessment of well-being: a systematic review and recommendations for future studies. J Happiness Stud. 2021;22(5):2361-2408. [FREE Full text] [CrossRef] [Medline]
- Doherty K, Balaskas A, Doherty G. The design of ecological momentary assessment technologies. Interact Comput. 2020;32(3):257-278. [CrossRef]
- Dunton G, Dzubur E, Li M, Huh J, Intille S, McConnell R. Momentary assessment of psychosocial stressors, context, and asthma symptoms in hispanic adolescents. Behav Modif. 2016;40(1-2):257-280. [FREE Full text] [CrossRef] [Medline]
- Paterson C, Armitage L, Turner M. Current landscape of ecological momentary assessment (real-time data) methodology in cancer research: a systematic review. Semin Oncol Nurs. 2023;39(6):151514. [FREE Full text] [CrossRef] [Medline]
- Nichols M, Miller S, Treiber F, Ruggiero K, Dawley E, Teufel Ii R. Patient and parent perspectives on improving pediatric asthma self-management through a mobile health intervention: pilot study. JMIR Form Res. 2020;4(7):e15295. [FREE Full text] [CrossRef] [Medline]
- Acorda D, Businelle M, Santa Maria D. Perceived impacts, acceptability, and recommendations for ecological momentary assessment among youth experiencing homelessness: qualitative study. JMIR Form Res. 2021;5(4):e21638. [FREE Full text] [CrossRef] [Medline]
- Adams LB, Watts T, DeVinney A, Haroz EE, Thrul J, Stephens JB, et al. Acceptability and feasibility of a smartphone-based real-time assessment of suicide among black men: mixed methods pilot study. JMIR Form Res. 2024;8:e48992. [FREE Full text] [CrossRef] [Medline]
- Heron KE, Dawson CA, Sandoval CM, Butler LV, Braitman AL, Cerezo A, et al. Refining an ecological momentary assessment study of binge eating among sexual minority and heterosexual young women: a mixed methods pilot study. Mhealth. 2023;9:33. [FREE Full text] [CrossRef] [Medline]
- Kivelä LMM, Fiß F, van der Does W, Antypa N. Examination of acceptability, feasibility, and iatrogenic effects of ecological momentary assessment (EMA) of suicidal ideation. Assessment. 2024;31(6):1292-1308. [FREE Full text] [CrossRef] [Medline]
- Overton M, Swain N, Falling C, Gwynne-Jones D, Fillingim R, Mani R. Experiences and perceptions of using smartphone ecological momentary assessment for reporting knee osteoarthritis pain and symptoms. Clin J Pain. 2023;39(9):442-451. [CrossRef] [Medline]
- Eldeirawi K, Huntington-Moskos L, Nyenhuis SM, Polivka B. Increased disinfectant use among adults with asthma in the era of COVID-19. J Allergy Clin Immunol Pract. 2021;9(3):1378-1380.e2. [FREE Full text] [CrossRef] [Medline]
- Brooke J. SUS: a quick and dirty usability scale. Usability Eval Ind. 1996;189:4-7. [CrossRef]
- Bangor A, Kortum PT, Miller JT. An empirical evaluation of the system usability scale. Int J Hum Comput Interact. 2008;24(6):574-594. [CrossRef]
- Lewis JR. The system usability scale: past, present, and future. Int J Hum Comput Interact. 2018;34(7):577-590. [CrossRef]
- IBM SPSS statistics for Windows. IBM. 2020. URL: https://www.ibm.com/products/spss-statistics [accessed 2024-09-30]
- Lewis JR, Sauro J. Item benchmarks for the system usability scale. J Usability Stud. 2018;13(3).
- Kim S, Stanton K, Park Y, Thomas S. A mobile app for children with asthma to monitor indoor air quality (AirBuddy): development and usability study. JMIR Form Res. 2022;6(5):e37118. [FREE Full text] [CrossRef] [Medline]
- Ratiu IA, Ligor T, Bocos-Bintintan V, Mayhew CA, Buszewski B. Volatile organic compounds in exhaled breath as fingerprints of lung cancer, asthma and COPD. J Clin Med. 2020;10(1):32. [FREE Full text] [CrossRef] [Medline]
- Binson VA, Subramoniam M, Sunny Y, Mathew L. Prediction of pulmonary diseases with electronic nose using SVM and XGBoost. IEEE Sensors J. 2021;21(18):20886-20895. [CrossRef]
Abbreviations
CAB: community advisory board |
EMA: ecological momentary assessment |
PM2.5: particulates 2.5 microns or less in diameter |
REDCap: Research Electronic Data Capture |
SUS: System Usability Scale |
TVOC: total volatile organic compound |
VOC: volatile organic compound |
Edited by A Mavragani; submitted 03.05.24; peer-reviewed by V Binson; comments to author 01.08.24; revised version received 05.09.24; accepted 24.09.24; published 10.10.24.
Copyright©Barbara Polivka, Kathryn Krueger, Olivia Bimbi, Luz Huntington-Moskos, Sharmilee Nyenhuis, Emily Cramer, Kamal Eldeirawi. Originally published in JMIR Formative Research (https://formative.jmir.org), 10.10.2024.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included.