Original Paper
Abstract
Background: Atrial fibrillation (AF) represents a hazardous cardiac arrhythmia that significantly elevates the risk of stroke and heart failure. Despite its severity, its diagnosis largely relies on the proficiency of health care professionals. At present, the real-time identification of paroxysmal AF is hindered by the lack of automated techniques. Consequently, a highly effective machine learning algorithm specifically designed for AF detection could offer substantial clinical benefits. We hypothesized that machine learning algorithms have the potential to identify and extract features of AF with a high degree of accuracy, given the intricate and distinctive patterns present in electrocardiogram (ECG) recordings of AF.
Objective: This study aims to develop a clinically valuable machine learning algorithm that can accurately detect AF and compare different leads’ performances of AF detection.
Methods: We used 12-lead ECG recordings sourced from the 2020 PhysioNet Challenge data sets. The Welch method was used to extract power spectral features of the 12-lead ECGs within a frequency range of 0.083 to 24.92 Hz. Subsequently, various machine learning techniques were evaluated and optimized to classify sinus rhythm (SR) and AF based on these power spectral features. Furthermore, we compared the effects of different frequency subbands and different lead selections on machine learning performances.
Results: The light gradient boosting machine (LightGBM) was found to be the most effective in classifying AF and SR, achieving an average F1-score of 0.988 across all ECG leads. Among the frequency subbands, the 0.083 to 4.92 Hz range yielded the highest F1-score of 0.985. In interlead comparisons, aVR had the highest performance (F1=0.993), with minimal differences observed between leads.
Conclusions: In conclusion, this study successfully used machine learning methodologies, particularly the LightGBM model, to differentiate SR and AF based on power spectral features derived from 12-lead ECGs. The performance marked by an average F1-score of 0.988 and minimal interlead variation underscores the potential of machine learning algorithms to bolster real-time AF detection. This advancement could significantly improve patient care in intensive care units as well as facilitate remote monitoring through wearable devices, ultimately enhancing clinical outcomes.
doi:10.2196/47803
Keywords
Introduction
Atrial fibrillation (AF) is the most prevalent cardiac arrhythmia, impacting an estimated 33.5 million people worldwide [
]. This severe cardiac condition heightens the risks of stroke and heart failure [ ]. Clinicians typically detect and diagnose AF through the noninvasive electrocardiogram (ECG) method. However, ECG interpretation relies heavily on the expertise of the medical professional, creating a need for automated ECG classification to support clinicians. Machine learning, a subset of artificial intelligence, has shown great potential in improving the detection and management of AF through automated ECG analysis [ ], risk stratification [ ], or treatment planning [ ].The 2020 PhysioNet Challenge data sets offer 12-lead ECG recordings that can be used to evaluate machine learning techniques for ECG interpretation [
]. Compared to machine learning approaches based on small and homogeneous data sets, algorithms using PhysioNet data are likely to be more representative of realistic clinical scenarios, thereby making them better suited for practical implementation. Various machine learning techniques have been used to detect AF using ECG data. Some of the widely explored methods include support vector machines, decision trees, random forests, and deep learning approaches like convolutional neural networks and recurrent neural networks. These techniques have demonstrated promising results in classifying normal sinus rhythm (SR) and AF, with fair accuracy and F1-scores [ ].The performance of machine learning algorithms depends on the quality of the input features. Common feature extraction methods in AF detection include time-domain analysis, frequency-domain analysis, and wavelet transform. Power spectral density (PSD) is a popular frequency-domain feature that has been used to differentiate SR from AF. PSD analysis reveals information about the distribution of a signal’s power and frequency components. An ECG signal comprises various frequency components, including those related to the sinus heartbeat as well as atrial and ventricular activity. The PSD distribution of these frequency components may alter heart conditions that affect the cardiac contraction cycle, making it a potential indicator for identifying cardiac arrhythmias. Consequently, we developed an automated machine learning algorithm based on PSD to differentiate normal SR from AF based on a large-scale data set from PhysioNet 2020.
Methods
ECG Data
We used the 2020 PhysioNet Challenge data sets (
) [ ], comprising the China Physiological Signal Challenge (CPSC) Database (men: n=3699, women: n=3178, total: n=6877, and sampling rate: 500 Hz), CPSC-Extra Database (men: n=1843, women: n=1610, total: n=3453, and sampling rate: 500 Hz), St Petersburg Institute of Cardiological Technics INCART 12-lead Arrhythmia Database (total: n=72 and sampling rate: 257 Hz), Physikalisch Technische Bundesanstalt (PTB) Diagnostic ECG Database (men: n=377, women: n=139, total: n=516, and sampling rate: 1000 Hz), Physikalisch Technische Bundesanstalt extra large (PTB-XL) electrocardiography Database (men: n=11,379, women: n=10,458, total: n=21,837, and sampling rate: 500 Hz), and Georgia 12-lead ECG Challenge Database (men: n=5551, women: n=4793, total: n=10,344, and sampling rate: 500 Hz). The PhysioNet Challenge data sets can be accessed publicly [ ], and data access is licensed under the Creative Commons Attribution 4.0 International Public License [ ].Properties | Data set | ||||||
CPSCa Database | CPSC-Extra Database | St Petersburg INCARTb Database | PTBc Diagnostic | PTB-XLd | Georgia | ||
Recording time | 6~60 seconds | 6~60 seconds | 30 minutes | Unknown | 10 seconds | 10 seconds | |
Sampling frequency (Hz) | 500 | 500 | 257 | 1000 | 500 | 500 | |
Participants, n | |||||||
Male | 3699 | 1843 | N/Ae | 377 | 11,379 | 5551 | |
Female | 3178 | 1610 | N/A | 139 | 10,458 | 4793 | |
Total | 6877 | 3453 | 72 | 516 | 21,837 | 10,344 |
aCPSC: China Physiological Signal Challenge.
bINCART: Institute of Cardiological Technics.
cPTB: Physikalisch Technische Bundesanstalt.
dPTB-XL: Physikalisch Technische Bundesanstalt extra large.
eN/A: not applicable.
From these data sets, we initially selected data featuring a 500 Hz sampling rate. Next, we identified ECG diagnoses using the Systematized Nomenclature of Medicine—Clinical Terminology codes 426783006 and 164889003 for SR and AF, respectively. This led to the identification of 20,766 SR and 3458 AF ECG recordings. After excluding recordings corresponding to multiple diagnoses, the final data set comprised 9102 SR and 1088 AF ECG recordings.
Ethical Considerations
This study was approved by the institutional review board of Taipei Veterans General Hospital (2022-04-004BC).
ECG Preprocessing and Feature Extraction
The ECG patterns associated with AF exhibit greater variability compared to those of SR. To explore this distinction, we used the Welch method [
, ] to estimate PSD and determine the frequency composition of the ECG signals. The recording durations of the ECG data ranged from 6 to 60 seconds, with 10 seconds being the most common. This variability could lead to differences in PSD resolution. To address this issue, we used the frequency bin method to ensure consistent frequency resolution across our PSD features. We set the frequency resolution to 1/6 Hz and calculated the arithmetic mean of the PSD frequencies within this resolution to represent the midpoint of each envelope. The data we used had a sampling rate of 500 Hz. Based on Nyquist-Shannon sampling theorem, the highest frequency information we can get is 250 Hz. After observing several data plots of the original PSD graph, we can see that most of the power of the signal is within 0 to 25 Hz. Thus, for a 10-second ECG recording, we selected a frequency of 0 to 25 Hz which was converted to 0.083 to 24.92 Hz. presents an example of original PSD plots and explains why we chose the PSD from 0 to 25 Hz. For further segmentation, it was just reasonable to separate the whole frequency segment into 5 smaller segments since the whole frequency ranges from 0 to 25 Hz. presents example ECG signals and PSD plots, highlighting notable differences in PSD between SR and AF; narrower harmonic frequency components can be observed in SR, while AF patterns display more erratic frequency components. We used these PSD features as inputs for our machine learning algorithm.Machine Learning Methods
Supervised machine learning is a type of machine learning where the algorithm is trained on a labeled data set, and the goal is to make predictions for new, unseen data. There are several types of supervised machine learning methods used in this study, including (1) discriminant analysis: a method for modeling the relationship between a dependent variable and one or more independent variables (used for continuous target variables); (2) logistic regression: a method for modeling the probability of a binary outcome based on one or more independent variables; (3) decision trees: a method for making predictions by creating a tree-like model of decisions and their potential consequences; (4) random forests: an ensemble method that combines multiple decision trees to make a prediction; (5) support vector machines: a method for classifying data by finding the best boundary (or “hyperplane”) that separates the classes; (6) neural networks: a method inspired by the structure and function of the human brain (can be used for a wide range of tasks, including classification and regression); and (7) naive Bayes: a probabilistic method for making predictions based on Bayes’ theorem (often used for text classification).
Additionally, we used a gradient boosting decision tree algorithm, namely light gradient boosting machine (LightGBM) [
]. It is one of the most efficient algorithms in recent years, known for its speed and accuracy. Boosting is an approach for combining multiple base models into a composite one. One of the ensemble tree algorithms of LightGBM is a “leaf-wise” tree algorithm, wherein the tree grows vertically; most of the others are “level-wise” tree algorithms, wherein the trees grow horizontally. The leaf-wise structure reduces time complexity and offers a favorable balance of accuracy and efficiency, especially for large-scale, high-dimensional data. Thus, it is useful in classification problems.Perceptrons are single-neuron models and the precursors to larger neural networks; now, they are the building blocks of neural networks. A deep neural network (DNN) is a supplement of a feed-forward neural network and consists of 3 types of layers: the input layer, the output layer, and the hidden layer. The input layer receives the input signal to be processed. The output layer performs the required task, such as prediction or classification. The true processing engine is the hidden layers, placed between the input and output layers. In a DNN, data flow from the input layer to the output layer, just as in feed-forward neural networks. The neurons are trained through back propagation. DNNs are widely used in various applications, including automated diagnosis using ECG data [
].Statistical Analysis
Data Imbalance
We used the synthetic minority over-sampling technique [
] to filter the data and reduce the imbalance between the numbers of SR and AF recordings (n=9102 and n=1088, respectively).F1-Score
To mitigate bias resulting from data imbalance, we used the F1-score as the primary metric for evaluating machine learning models. F1-scores treat false-positive and false-negative errors equally and are more useful than accuracy in cases of class imbalance. The F1-score is the harmonic mean of precision and recall, which measures the errors contributed by false positives and false negatives, respectively.
Training, Validation, and Testing Data Sets
We divided our data sets into training, validation, and testing sets. The training set was used to develop the models, the validation set for model tuning, and the testing set for model assessment. In this study, 60% of the data comprised the training set, 20% the validation set, and 20% the testing set. For model tuning, we used ensemble learning to identify optimal parameters for each model based on the validation set.
Results
Comparison of the Performance of Various Machine Learning Algorithms
We evaluated various machine learning methods, including extra tree, LightGBM (Microsoft Corporation), CatBoost (Yandex), XGBoost (The XGBoost Contributors), decision tree, k-nearest neighbors, stochastic gradient descent, gradient boosting, random forest, naïve Bayesian, logistic regression, and DNN. Our analysis reveals that machine learning algorithms with boosting methods outperform those without boosting. In particular, LightGBM outperformed the other methods, achieving the highest average F1-score of 0.988 across all 12 ECG leads and the lowest computation time for features within the entire frequency range (0.083-24.92 Hz). Conversely, our results indicate that the naive Bayesian algorithm performs poorly in classifying SR and AF. Despite its simplicity, naive Bayesian appears to be less suited for this specific task, and alternative approaches should be considered for better accuracy and reliability. Thus, we focused solely on LightGBM for subsequent analyses.
Effect of Frequency Band on Model Performance
We examined the contributions of various frequency subbands of ECG PSD features to model performance in detecting AF (
). The entire frequency range was divided into 5 subbands (0.083-4.92, 5.083-9.92, 10.083-14.92, 15.083-19.92, and 20.083-24.92 Hz). The highest overall F1-score was achieved by the model using the full frequency range (0.083-24.92 Hz), and the frequency subband of 0.083 to 4.92 Hz yielded the highest F1-score among the subbands. Generally, the F1-score for each subband was around 0.9, indicating that every subband contains valuable information for ECG classification.Performance | Frequency range | |||||
Whole range | 0.083-4.92 Hz | 5.083-9.92 Hz | 10.083-14.92 Hz | 15.083-19.92 Hz | 20.083-24.92 Hz | |
F1-score | 0.988 | 0.985 | 0.956 | 0.925 | 0.912 | 0.900 |
Interlead Differences in Model Performance
In lead comparisons, aVR demonstrated the highest performance across all frequency subbands, although the differences between leads were minimal (
). Specifically, for the entire frequency range, using aVL resulted in the lowest classification performance (F1-score=0.980), while using aVR achieved the highest performance (F1-score=0.993).Frequency range | Different leads | |||||||||||
l1 | l2 | l3 | aVR | aVL | aVF | V1 | V2 | V3 | V4 | V5 | V6 | |
Whole range | 0.985 | 0.990 | 0.981 | 0.993 | 0.980 | 0.984 | 0.988 | 0.988 | 0.991 | 0.991 | 0.990 | 0.989 |
0.083-4.92 Hz | 0.980 | 0.989 | 0.978 | 0.990 | 0.980 | 0.980 | 0.986 | 0.988 | 0.987 | 0.990 | 0.990 | 0.987 |
5.083-9.92 Hz | 0.961 | 0.968 | 0.930 | 0.978 | 0.936 | 0.957 | 0.961 | 0.947 | 0.959 | 0.958 | 0.963 | 0.958 |
10.083-14.92 Hz | 0.920 | 0.928 | 0.900 | 0.949 | 0.917 | 0.921 | 0.926 | 0.923 | 0.936 | 0.940 | 0.912 | 0.937 |
15.083-19.92 Hz | 0.878 | 0.915 | 0.854 | 0.948 | 0.900 | 0.909 | 0.920 | 0.907 | 0.923 | 0.927 | 0.938 | 0.924 |
20.083-24.92 Hz | 0.868 | 0.915 | 0.857 | 0.939 | 0.871 | 0.885 | 0.877 | 0.882 | 0.920 | 0.916 | 0.940 | 0.925 |
Discussion
Principal Findings
In this study, we found that the LightGBM algorithm was the most effective machine learning model for our purposes. Notably, all frequency subbands contained distinct information, achieving independent F1-scores of approximately 0.9. Consequently, using the entire frequency range (0.083-24.92 Hz) provided the most comprehensive features and yielded the highest F1-score of 0.988. Interestingly, among the limb leads, aVR produced the best result, which was marginally superior to the outcomes of chest leads and lead II. This finding is unexpected, as lead aVR is rarely used in real-world scenarios for detecting arrhythmia. The contributions of different frequency bands to classification performance showed that even though each subband contains unique features, the dominant frequency subband (0.083-4.92 Hz) is sufficient for distinguishing AF from SR.
In terms of the contributions of frequency bands to classification performance, it is important to note that the normal human heart beats between 60 to 100 times per minute (1-1.67 Hz), whereas the dominant frequency in AF ranges from 3.8 to 8 Hz [
]. Given the differences in frequency components between SR and AF, they can be used to distinguish one from the other. As demonstrated in , multiple frequency peaks are observed within the 0 to 25 Hz range for both SR and AF. Consequently, frequency subbands containing distinct features may yield different results.Initially, we hypothesized that the subband containing the dominant frequency (0.083-4.92 Hz) would result in the optimal classification of SR and AF, similar to the whole frequency range (0.083-24.92 Hz), while other subbands would struggle to classify SR and AF effectively. Indeed, models using the dominant frequency subband performed well, with results closely resembling those of models using the whole frequency range. However, other subbands also demonstrated high performance independently (
), with F1-scores exceeding 0.854. The dominant frequency subband (0.083-4.92 Hz) yielded an F1-score of 0.985, which is comparable to that of the whole frequency range (F1-score=0.988). These findings suggest that although each subband contains unique features and cannot be replaced by other subbands, the dominant frequency subband alone is sufficient for differentiating AF from SR.In this study, we explore the variations in AF classification performance across different ECG leads. Each ECG lead has unique physiological applications, which in turn influence the preference of medical professionals in identifying specific types of arrhythmias. For instance, lead 1, aVF, or V1 are frequently used in diagnosing right ventricular hypertrophy. Routine clinical practice suggests that lead 2, which is typically the focus of medical professionals when examining AF, would yield the most accurate results. Surprisingly, our findings revealed that all leads, within the frequency range of 0.083-24.92 Hz, generated F1-scores in close proximity to 0.985. Among these, lead aVR achieved the highest F1-score at 0.993. We believe this can be attributed to the visibility of AF in the majority of leads and the comprehensive features encompassed by the entire frequency range.
Contrary to our initial expectations, lead aVR, which is not a common choice in clinical settings, produced the most optimal results when using subbands [
]. This finding may potentially shed light on the reentry mechanism that underlies AF [ , ]. It is worth noting that lead aVR captures data from the right ventricle outflow tract and the basal portion of the septum, whereas AF predominantly manifests in the left ventricle. Consequently, the reentry mechanism emerges as the most plausible explanation for this observed phenomenon.In a prior study [
], the 2020 PhysioNet Challenge data sets were used alongside the LightGBM machine learning algorithm. However, the approaches to signal extraction and processing in that study differed from those used in our research. The previous study implemented filtering techniques and wavelet multiresolution analysis, while our investigation used PSD and the Welch method. Another key distinction between the 2 studies is the scope of the classification task. While our research focused solely on differentiating AF from SR, the previous study attempted to identify 24 different diseases. Due to the varied physiological information provided by each ECG lead, we opted to compare the performance of LightGBM for each individual lead, rather than inputting data from all 12 leads into the LightGBM simultaneously. Furthermore, our study identified the most critical frequency subband within the total frequency range. We determined the dominant frequency subband to be 0.083-4.92 Hz, which played a significant role in our analysis.There are several limitations to be addressed in this study. One notable constraint is our selection of 10-second ECG recordings, which may not accurately represent the full spectrum of real-world clinical scenarios. The data sets used in this study were predominantly clean, while actual clinical situations may involve data contaminated by noise, potentially affecting the results. Moreover, our study focused exclusively on single-diagnosis data, representing either AF or SR. This approach, however, does not account for the possibility of a patient experiencing multiple arrhythmias concurrently. Consequently, our findings were derived under simplified conditions that may not fully reflect the complexity of real-life cases. In light of these limitations, it is essential to interpret our results with caution and consider further research that incorporates a broader range of ECG recordings, addresses potential noise-related challenges, and examines cases with multiple coexisting arrhythmias to enhance the generalizability and applicability of our findings to real-world clinical settings.
In summary, LightGBM proves to be a highly effective algorithm for distinguishing AF from SR. Our study demonstrated that when dividing the entire ECG frequency range into subbands with fewer features, lead aVR delivered the best performance. This outcome could potentially be associated with the underlying pathological mechanisms of AF. By incorporating adequate frequency band features, lead 2 ECG data can achieve an F1-score of approximately 0.99. This level of accuracy and efficiency of the LightGBM model renders the algorithm suitable for implementation in clinical practice and integration into commercialized electronic devices, such as the smartwatch with the ECG functionality, for a range of health care applications. This study’s findings suggest that leveraging the power of LightGBM could enhance arrhythmia detection and monitoring, ultimately improving patient care and outcomes.
Literature Review
In this review, we will talk about studies that introduce techniques for AF detection, analyzing their methods, results, and potential implications in the field of cardiology. First, one study [
] proposed a feature extraction method based on a gradient set for AF detection, which features simplicity, noise tolerance, and adaptability to various classifiers. However, we can still improve the feature extraction method in the future, such as improving AF detection performance by proposing a more representative feature set or combining it with other types of features. This approach shows the potential for streamlined, efficient feature extraction, providing a solid foundation for further research in the domain.Next, the Transposed Projection–Convolutional Neural Network (TP-CNN) method was introduced in another study [
], aiming to use “compressed ECG signals” for AF detection. The approach demonstrates promising results in accurately detecting AF in wearable application scenarios while addressing energy consumption concerns. It shows the effective use of compressed signals and a highly accurate algorithm. Yet, its data sources only contain 25 patients. More patients should be included in further studies.Another study [
] demonstrates a unique method using multiple parameters, including the average number of f waves in a TQ interval, showing robust real-time AF detection capabilities. This approach not only differentiates between AF and normal ECGs but also outperforms distinguishing AF from other arrhythmias. However, they can discuss more about how their algorithms will be implemented in clinical situations.There is another study [
] focusing on low-complexity algorithms for AF detection, a method based on RR interval features. This approach demonstrated reasonable feature selection while maintaining a low computational cost, making it suitable for low-power devices. However, in future studies, it should focus on getting a better F1-score.In addition to ECG AF detection, there is also a signal called photoplethysmography common in wearable devices for AF detection, while we usually use ECG in clinical situations. This Fitbit Heart study [
] provides an algorithm that exhibited a high positive predictive value for concurrent AF, highlighting the potential of consumer wearables for large-scale AF identification. Though the result is nice, we hope we can know more about photoplethysmography comparison with ECG.In conclusion, these studies collectively contribute to the evolving landscape of AF detection methods. While each approach offers unique advantages, further research should focus on refining these methods, exploring real-time applications, and enhancing the overall accuracy and efficiency of AF detection algorithms. Potential limitations should also be emphasized in future studies.
Acknowledgments
This study was supported by the National Science and Technology Council of Taiwan with grants to ACY (grant MOST 111-2622-8-075-002-IE, MOST 111-2321-B-A49-007, MOST 111-2628-B-A49-012, MOST 111-2321-B-A49-011, and NSTC 111-2634-F-A49-014). ACY was also supported by the Mt Jade Young Scholarship Award from the Ministry of Education, Taiwan, as well as Brain Research Center, National Yang Ming Chiao Tung University, and the Ministry of Education (Aim for the Top University Plan), Taipei, Taiwan. All the funding resources provided financial supports only and had no other role in study design, data collection, analysis, or interpretations.
Data Availability
The data sets generated and analyzed during the current study are available in the 2020 PhysioNet Challenge data sets repository [
].Conflicts of Interest
None declared.
References
- Chugh SS, Havmoeller R, Narayanan K, Singh D, Rienstra M, Benjamin EJ, et al. Worldwide epidemiology of atrial fibrillation: a Global Burden of Disease 2010 study. Circulation. 2014;129(8):837-847. [FREE Full text] [CrossRef] [Medline]
- Staerk L, Sherer JA, Ko D, Benjamin EJ, Helm RH. Atrial fibrillation: epidemiology, pathophysiology, and clinical outcomes. Circ Res. 2017;120(9):1501-1517. [FREE Full text] [CrossRef] [Medline]
- Reichlin T, Abächerli R, Twerenbold R, Kühne M, Schaer B, Müller C, et al. Advanced ECG in 2016: is there more than just a tracing? Swiss Med Wkly. 2016;146:w14303. [CrossRef] [Medline]
- Tseng AS, Noseworthy PA. Prediction of atrial fibrillation using machine learning: a review. Front Physiol. 2021;12:752317. [FREE Full text] [CrossRef] [Medline]
- Tang S, Razeghi O, Kapoor R, Alhusseini MI, Fazal M, Rogers AJ, et al. Machine learning-enabled multimodal fusion of intra-atrial and body surface signals in prediction of atrial fibrillation ablation outcomes. Circ Arrhythm Electrophysiol. 2022;15(8):e010850. [FREE Full text] [CrossRef] [Medline]
- Alday EAP, Gu A, Shah AJ, Robichaux C, Wong AKI, Liu C, et al. Classification of 12-lead ECGs: the PhysioNet/computing in cardiology challenge 2020. Physiol Meas. 2021;41(12):124003. [FREE Full text] [CrossRef] [Medline]
- Alday EAP, Gu A, Shah A, Liu C, Sharma A, Seyedi S, et al. Classification of 12-lead ECGs: the PhysioNet/Computing in Cardiology Challenge 2020. PhysioNet. Jul 29, 2022. URL: https://physionet.org/content/challenge-2020/1.0.2/ [accessed 2024-01-16]
- Attribution 4.0 International (CC BY 4.0). Creative Commons. URL: https://creativecommons.org/licenses/by/4.0/ [accessed 2024-01-22]
- Sheikh SA, Majoka AZ, Rehman KU, Razzaq N, Zaidi T. Nonparametric spectral estimation technique to estimate dominant frequency for atrial fibrillation detection. J Signal Inf Process. 2015;06(04):266-276. [FREE Full text] [CrossRef]
- Welch P. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. IEEE Trans Audio Electroacoustics. 1967;15(2):70-73. [FREE Full text] [CrossRef]
- Ke G, Meng Q, Finley T, Wang T, Chen W, Ma W, et al. LightGBM: A highly efficient gradient boosting decision tree. Presented at: 31st Conference on Neural Information Processing Systems (NIPS 2017); December 4-9, 2017, 2017; Long Beach, CA. URL: https://proceedings.neurips.cc/paper/2017/file/6449f44a102fde848669bdd9eb6b76fa-Paper.pdf
- Ribeiro AH, Ribeiro MH, Paixão GMM, Oliveira DM, Gomes PR, Canazart JA, et al. Automatic diagnosis of the 12-lead ECG using a deep neural network. Nat Commun. Apr 09, 2020;11(1):1760. [CrossRef] [Medline]
- Chawla NV, Bowyer KW, Hall LO, Kegelmeyer WP. SMOTE: synthetic minority over-sampling technique. J Artif Intell Res. 2002;16:321-357. [FREE Full text] [CrossRef]
- Bollmann A, Kanuru NK, McTeague KK, Walter PF, DeLurgio DB, Langberg JJ. Frequency analysis of human atrial fibrillation using the surface electrocardiogram and its response to ibutilide. Am J Cardiol. 1998;81(12):1439-1445. [FREE Full text] [CrossRef] [Medline]
- George A, Arumugham PS, Figueredo VM. aVR - the forgotten lead. Exp Clin Cardiol. 2010;15(2):e36-e44. [FREE Full text] [Medline]
- Iwasaki Y, Nishida K, Kato T, Nattel S. Atrial fibrillation pathophysiology: implications for management. Circulation. 2011;124(20):2264-2274. [FREE Full text] [CrossRef] [Medline]
- Waks JW, Josephson ME. Mechanisms of atrial fibrillation - reentry, rotors and reality. Arrhythm Electrophysiol Rev. 2014;3(2):90-100. [FREE Full text] [CrossRef] [Medline]
- Zisou C, Sochopoulos A, Kitsios K. Convolutional recurrent neural network and LightGBM ensemble model for 12-lead ECG classification. Presented at: 2020 Computing in Cardiology Conference; September 13-16, 2020, 2020; Rimini, Italy. [CrossRef]
- Wang H, Dai H, Zhou Y, Zhou B, Lu P, Zhang H, et al. An effective feature extraction method based on GDS for atrial fibrillation detection. J Biomed Inform. 2021;119:103819. [FREE Full text] [CrossRef] [Medline]
- Zhang H, Dong Z, Sun M, Gu H, Wang Z. TP-CNN: A detection method for atrial fibrillation based on transposed projection signals with compressed sensed ECG. Comput Methods Programs Biomed. 2021;210:106358. [CrossRef] [Medline]
- Du X, Rao N, Qian M, Liu D, Li J, Feng W, et al. A novel method for real-time atrial fibrillation detection in electrocardiograms using multiple parameters. Ann Noninvasive Electrocardiol. 2014;19(3):217-225. [FREE Full text] [CrossRef] [Medline]
- Sadr N, Jayawardhana M, Pham TT, Tang R, Balaei AT, de Chazal P. A low-complexity algorithm for detection of atrial fibrillation using an ECG. Physiol Meas. 2018;39(6):064003. [FREE Full text] [CrossRef] [Medline]
- Lubitz SA, Faranesh AZ, Selvaggi C, Atlas SJ, McManus DD, Singer DE, et al. Detection of atrial fibrillation in a large population using wearable devices: the fitbit heart study. Circulation. 2022;146(19):1415-1424. [FREE Full text] [CrossRef] [Medline]
Abbreviations
AF: atrial fibrillation |
CPSC: China Physiological Signal Challenge |
DNN: deep neural network |
ECG: electrocardiogram |
INCART: Institute of Cardiological Technics |
LightGBM: light gradient boosting machine |
PSD: power spectral density |
PTB: Physikalisch Technische Bundesanstalt |
PTB-XL: Physikalisch Technische Bundesanstalt extra large |
SR: sinus rhythm |
TP-CNN: Transposed Projection–Convolutional Neural Network |
Edited by A Mavragani; submitted 02.04.23; peer-reviewed by F Ferdowsy, H Tanaka, Z Huang; comments to author 17.05.23; revised version received 29.06.23; accepted 02.11.23; published 11.03.24.
Copyright©Beau Bo-Sheng Chuang, Albert C Yang. Originally published in JMIR Formative Research (https://formative.jmir.org), 11.03.2024.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included.