<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Form Res</journal-id><journal-id journal-id-type="publisher-id">formative</journal-id><journal-id journal-id-type="index">27</journal-id><journal-title>JMIR Formative Research</journal-title><abbrev-journal-title>JMIR Form Res</abbrev-journal-title><issn pub-type="epub">2561-326X</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v10i1e89441</article-id><article-id pub-id-type="doi">10.2196/89441</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Digital Anterior Segment Photography in Clinical Practice: Mixed Methods Study</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Naik</surname><given-names>Vidhi</given-names></name><degrees>MBChB</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Scantling-Birch</surname><given-names>Yarrow</given-names></name><degrees>BSc, BMBS, MSc</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Jones</surname><given-names>Emma</given-names></name><degrees>MA, MBBS, MSc, MRCP</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Ramessur</surname><given-names>Rishi</given-names></name><degrees>BM BCh, MSc</degrees><xref ref-type="aff" rid="aff3">3</xref></contrib></contrib-group><aff id="aff1"><institution>Aberdeen Royal Infirmary</institution><addr-line>Aberdeen</addr-line><country>United Kingdom</country></aff><aff id="aff2"><institution>Moorfields Eye Hospital NHS Foundation Trust</institution><addr-line>London</addr-line><country>United Kingdom</country></aff><aff id="aff3"><institution>School of Informatics, University of Edinburgh</institution><addr-line>Room 3.42, Informatics Forum, 10 Crichton Street</addr-line><addr-line>Edinburgh</addr-line><country>United Kingdom</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Sarvestan</surname><given-names>Javad</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Losa</surname><given-names>Klark Becerro de Bengoa</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Giardini</surname><given-names>ME</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Rishi Ramessur, BM BCh, MSc, School of Informatics, University of Edinburgh, Room 3.42, Informatics Forum, 10 Crichton Street, Edinburgh, EH8 9AB, United Kingdom, +44 131 651 5661; <email>R.Ramessur@sms.ed.ac.uk</email></corresp></author-notes><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>4</day><month>9</month><year>2026</year></pub-date><volume>10</volume><elocation-id>e89441</elocation-id><history><date date-type="received"><day>12</day><month>12</month><year>2025</year></date><date date-type="rev-recd"><day>16</day><month>08</month><year>2026</year></date><date date-type="accepted"><day>23</day><month>08</month><year>2026</year></date></history><copyright-statement>&#x00A9; Vidhi Naik, Yarrow Scantling-Birch, Emma Jones, Rishi Ramessur. Originally published in JMIR Formative Research (<ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>), 4.9.2026. </copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://formative.jmir.org/2026/1/e89441"/><abstract><sec><title>Background</title><p>In the digital era, smartphone technology has significantly advanced ocular imaging, allowing for high-resolution anterior segment photography (ASP) to enhance referrals, decision-making, and disease monitoring within clinical workflows.</p></sec><sec><title>Objective</title><p>This exploratory quality-improvement project aims to examine clinician experiences with 4 smartphone-based and slit-lamp&#x2013;based ASP workflows used in eye casualty and corneal services.</p></sec><sec sec-type="methods"><title>Methods</title><p>A mixed methods project was conducted at a tertiary eye hospital in England (United Kingdom) between October 21, 2024, and December 6, 2024. The full imaging setups of 4 ASP workflows were evaluated within an established clinical setting: the Magnifier app (a smartphone-based app; Apple Inc), QuikVue smartphone adapter (a smartphone-based camera lens attachment; VisuScience Meditech Co Ltd), NexYZ Slit-Lamp Adapter (a slit-lamp&#x2013;based attachment; Celestron LLC), and Zeiss Slit Lamp Imaging Solution (ZSLIS; an integrated slit-lamp camera system; Carl Zeiss AG). Ophthalmology residents and corneal fellows completed nonvalidated usability surveys and participated in one-on-one interviews examining the role of ASP workflows in clinical practice. Survey data were analyzed using descriptive statistics. Interviews were transcribed and subjected to reflexive thematic analysis.</p></sec><sec sec-type="results"><title>Results</title><p>Among 25 survey respondents (17 residents and 8 fellows) and 12 interviewees, clinician-rated assessments of usability, cost-effectiveness, and clinical utility favored the Magnifier workflow, which received the highest ratings across these domains (19/25, 76%; 23/25, 92%; and 18/25, 72% strongly agreed, respectively). Five themes emerged from qualitative analysis: obstacles to clinical implementation, accessibility, quality and workflow, digital ethics, and innovation.</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>No single ASP workflow proved superior in usability ratings and interview themes regarding clinical application. However, the use of the Magnifier workflow appeared to offer the most favorable balance of usability, cost-effectiveness, and clinical utility in clinician-rated assessments, though this reflects the full imaging workflow rather than the app alone. These findings are exploratory and require future work to examine workflow integration, data governance for smartphone imaging, and patient perspectives on ASP workflows.</p></sec></abstract><kwd-group><kwd>anterior eye segment</kwd><kwd>smartphone</kwd><kwd>photography</kwd><kwd>telemedicine</kwd><kwd>keratitis</kwd><kwd>diagnostic imaging</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>Demand for ophthalmology services in the United Kingdom is rising with around 2.2 million people living with visual impairment [<xref ref-type="bibr" rid="ref1">1</xref>]. An aging population drives this increase, with higher rates of ocular comorbidities and greater health care access requirements, thereby increasing workforce constraints [<xref ref-type="bibr" rid="ref2">2</xref>]. Simultaneously, access to urgent and emergency eye care has expanded, with ophthalmic cases comprising 2% to 6% of emergency attendances [<xref ref-type="bibr" rid="ref3">3</xref>]. Streamlining the patient pathway, particularly referrals, can ease service pressure. Evidence shows that including clinical photographs with referral histories improves diagnostic accuracy compared with written histories alone, potentially reducing the burden on Hospital Eye Services (HES) [<xref ref-type="bibr" rid="ref4">4</xref>].</p><p>The anterior segment (AS) can be effectively imaged through anterior segment photography (ASP), which integrates the latest smartphone or smart tablet camera technology with the slit lamp. When combined with electronic patient records (EPRs), this surpasses clinical diagrams, enhances documentation, and allows for image-based triage. This allows for improved monitoring of challenging cases like infectious keratitis, which can be difficult to distinguish between infective organisms and support machine-learning models that allow for automated image-based screening and AI research [<xref ref-type="bibr" rid="ref5">5</xref>].</p><p>Our project&#x2019;s objective was to assess how 4 different ASP workflows&#x2014;smartphone-based, slit-lamp&#x2013;based, or integrated slit-lamp camera system&#x2014;could be used among clinicians at a busy tertiary eye hospital.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Study Design and Setting</title><p>This exploratory mixed methods evaluation was cross-sectional, survey-based, and interview-based, designed to characterize clinician experience across 4 ASP workflows rather than test predefined hypotheses. The project ran from October 21 to December 6, 2024, at Moorfields Eye Hospital (MEH; City Road site, United Kingdom) eye casualty and outpatient cornea clinics. As an exploratory, single-center quality improvement evaluation, this project is intended to characterize clinician experience and generate hypotheses for future research, rather than provide definitive or generalizable comparisons between ASP workflows.</p></sec><sec id="s2-2"><title>ASP Workflows</title><p>Four standardized ASP workflows, each including distinct categories, were evaluated in this project in the eye casualty and corneal services. Workflows were defined and categorized, according to a recent scoping review, into smartphone-based devices (with or without attachments) and slit-lamp&#x2013;based devices (slit-lamp cameras, conventional slit-lamps equipped with a digital camera, and slit-lamps equipped with a smartphone) [<xref ref-type="bibr" rid="ref6">6</xref>]. Each device was integrated into a standard clinic workflow. A workflow was defined as the following standard of care: a patient was invited from the waiting room to an examination cubicle (estimated 12 m&#x00B2;), an appropriate history and examination were conducted after obtaining appropriate consent, the room light was turned off to maximize slit-lamp examination findings or set to ambient lighting (estimated 4000 K) to maximize smartphone-based examinations, and the specific ASP workflow of interest was assessed according to the manufacturer&#x2019;s photo-capture instructions. These are described in further detail below.</p><p>The smartphone-based workflows comprised the Magnifier app (Apple Inc; <xref ref-type="fig" rid="figure1">Figure 1A</xref>), an iOS app running on an iPhone 13 Pro (Apple Inc) that isolates the ultrawide (macrocapable) lens to provide steady zoom and fixed focal length, and the QuikVue (VisuScience Meditech Co Ltd; <xref ref-type="fig" rid="figure1">Figure 1B</xref>), a macro lens attachment with built-in illumination and cobalt-blue filter, providing 10&#x00D7; magnification at a fixed focal length when coupled to a compatible smartphone [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref8">8</xref>].</p><p>The slit-lamp&#x2013;based workflows comprised the NexYZ (Celestron LLC; <xref ref-type="fig" rid="figure1">Figure 1C</xref>), a universal smartphone adapter mounted to the slit-lamp eyepiece to enable image capture through slit-lamp optics, and the Zeiss Slit Lamp Imaging Solution (ZSLIS, Carl Zeiss AG; <xref ref-type="fig" rid="figure1">Figure 1D</xref>), an integrated slit-lamp camera system producing high-resolution images via a dedicated optical and camera assembly [<xref ref-type="bibr" rid="ref9">9</xref>,<xref ref-type="bibr" rid="ref10">10</xref>]. The NexYZ workflow was assessed by coupling a smartphone to the adapter before mounting onto the slit-lamp (Haag-Streit BM 900), thereby using the optics of both the smartphone and the slit-lamp (diffuse illumination settings: 10&#x00D7; magnification, illumination angle 45&#x00B0;, 8&#x00D7;14 mm beam [height &#x00D7; width], and low illumination intensity with a diffused light source). The ZSLIS workflow was the only one that did not require a smartphone for image capture.</p><p>In the case of smartphone-based workflows or slit-lamps equipped with a smartphone, a standardized iPhone 13 Pro (owned by a member of the project team with no ancillary accessories, such as a case) was used with the standard camera app native to iOS or the Magnifier app. The settings across ASP workflows changed only when applied to the Magnifier app, which isolates the ultrawide camera (12-megapixel, 13 mm lens, aperture f/1.8, and shutter speed 1/100 s). For all other workflows, the smartphone Camera app settings were set as follows, using the main telephoto camera (12-megapixel, 26 mm lens, aperture f/2.8, and shutter speed 1/100 s): fixed zoom (1&#x00D7;), fixed brightness and exposure at the automatic midpoint, no flash, auto-focus, and image-size exportation (maximum resolution, 4032&#x00D7;3024) [<xref ref-type="bibr" rid="ref11">11</xref>].</p><p>Throughout this manuscript, references to a named ASP device (eg, the NexYZ) denote the complete clinical workflow in which it was evaluated. This includes, if applicable, the coupled smartphone, slit-lamp optics, room lighting, capture software with associated settings, and the image-handling pathway, rather than the isolated device. Outcomes reported reflect this full workflow and not the hardware component alone. For the purposes of readability, a named ASP device (eg, the NexYZ) may be used as shorthand for the complete workflow, not the isolated component.</p><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>A sketch of the 4 anterior segment photography (ASP) workflows evaluated in this project. Illustrations were produced using the Procreate app (Savage Interactive): (A) Magnifier app, (B) QuikVue, (C) NexYZ, and (D) Zeiss Slit Lamp Imaging Solution.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v10i1e89441_fig01.png"/></fig></sec><sec id="s2-3"><title>Ethical Considerations</title><p>This project was registered with and approved by the MEH Clinical Audit Department as a quality-improvement project (QIP; project number 1606). Formal National Health Service (NHS) Research Ethics Committee review was not sought because the project was classified locally as a QIP rather than research. This classification reflected that the project evaluated clinicians&#x2019; experience of ASP workflows already available or in use in standard clinical practice, with the primary purpose of informing local service improvement, workflow integration, documentation, and governance. The project did not allocate participants to an intervention, alter clinical care, or test a predefined hypothesis of clinical efficacy or diagnostic accuracy. This approach is consistent with UK Health Research Authority guidance distinguishing research from audit or service evaluation [<xref ref-type="bibr" rid="ref12">12</xref>].</p><p>All clinician participants participated voluntarily and provided informed consent before survey participation and/or interview audio recording. For the illustrative clinical case images, patient consent was obtained in accordance with the MEH Patient Agreement to Media Recordings. This meant all patient-identifiable images were handled in line with the Data Protection Act 2018, the UK General Data Protection Regulation (GDPR), NHS England Bring Your Own Device (BYOD) guidance, and local governance policies [<xref ref-type="bibr" rid="ref13">13</xref>,<xref ref-type="bibr" rid="ref14">14</xref>]. Clinical images were captured on an approved iPhone 13 Pro using airplane mode to prevent transfer of images via cellular or unsecure networks. Captured images were immediately transferred to a secure NHS file server via a USB-linked file transfer to a clinical computer. Images were deleted immediately following transfer from the iPhone 13 Pro: no images were stored in the device&#x2019;s general photo library or in an app-specific library, or transmitted via personal messaging or unsecure networks. This is all per the NHS England BYOD guidance and in keeping with local data protection policies. Survey and interview data were anonymized and deidentified before analysis. No participants received compensation for project participation.</p></sec><sec id="s2-4"><title>Project Recruitment</title><p>Corneal fellows and ophthalmology residents at MEH, City Road, were recruited to complete a survey and voluntary semistructured interviews. The recruitment process involved a project coordinator (VN) rotating through morning and afternoon sessions in the eye casualty and outpatient corneal clinics and approaching residents and fellows in these clinics about the QIP, with the available workflows present (excluding the ZSLIS); a total of 6 eye casualty sessions and 5 corneal clinics were visited during the period of October 21 to December 6, 2024.</p><p>All ophthalmology residents receive induction training for the ZSLIS prior to commencing a placement at MEH; therefore, familiarity with this system was assumed. All project participants had prior experience with smartphone-based ASP (defined as a general familiarity with smartphone photography for clinical ophthalmic assessment rather than the specific workflows tested), ensuring baseline familiarity. Prior experience with a tested ASP workflow was not an exclusion criterion, since the clinician&#x2019;s perspective was still valuable information. Participants were further engaged through a hands-on familiarity exercise, lasting approximately 5 minutes and including practice in image capture and free exploration of each workflow&#x2019;s features, prior to survey and interview administration.</p><p>To provide illustrative images and contextualize each ASP workflow within a diagnostic pathway, a single clinical case was used. A patient with corneal pathology attending the eye casualty was recruited with informed consent in accordance with the MEH Patient Agreement to Media Recordings. Images were captured by an ophthalmology resident (YS-B) using each of the 4 ASP workflows, including the same smartphone (iPhone 13 Pro) where applicable, during a single clinical encounter. Image acquisition was performed in either ambient lighting (estimated 4000 K) for smartphone-based examinations, except for the NexYZ which used slit-lamp optics, or with the room lights turned off for slit-lamp&#x2013;based examinations. Two clinical examination cubicles were used; the ZSLIS required a separate cubicle as it used an integrated imaging system with a dedicated computer. Files from the ZSLIS were transferred to a secure NHS email account and stored on a secure NHS file server. For all other smartphone-based assessments, the native iOS camera app (iPhone 13 Pro) was used, except for the Magnifier workflow. Magnifier and camera settings were applied as described previously, and cubicle lighting and patient positioning were kept consistent between the 2 environments.</p><p>Participants were introduced to the project aims and given a short tutorial on each ASP workflow to standardize knowledge among clinicians. Surveys and interviews were designed to maximize user reflections on each ASP workflow and were not intended for formal hypothesis generation or statistical comparison. Each interview concluded with a discussion of differential diagnoses for a single clinical case, presented as the following vignette: a young male contact lens wearer presenting to eye casualty with a 24-hour history of eye pain and a corneal opacity on examination. Further discussion around global image characteristics across all 4 ASP workflows, including perceived functionality and costs, was held during interviews.</p><p>Formal sample size and power calculations were not conducted, reflecting the project&#x2019;s exploratory design. Instead, target sample sizes were informed by prior literature and the practical limitations of recruiting within a niche specialty cohort. Twelve interviews were deemed sufficient for achieving thematic saturation, beyond which no new codes, subthemes, or themes are generated [<xref ref-type="bibr" rid="ref15">15</xref>]. A sufficient benchmark for survey responses was deemed based on the limited number of residents at a single tertiary eye center, ranging between 20 and 30, and previous survey-based studies, among ophthalmology residents, ranging between 16 and 26 [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref17">17</xref>].</p></sec><sec id="s2-5"><title>Survey Creation</title><p>The survey underwent dynamic iterative review (VN, YS-B, and RR) to optimize its design, alongside the adaptation of previously validated surveys: the System Usability Scale (SUS), a simple 5-point Likert scale (eg, &#x201C;strongly disagree,&#x201D; &#x201C;disagree,&#x201D; &#x201C;neither agree nor disagree,&#x201D; &#x201C;agree,&#x201D; and &#x201C;strongly agree&#x201D;) used to measure subjective assessments of usability, and the mHealth App Usability Questionnaire (MAUQ), a questionnaire developed from existing validated surveys to assess the usability of a novel health care smartphone app [<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref19">19</xref>]. The final survey (<xref ref-type="supplementary-material" rid="app1">Multimedia Appendix 1</xref>) used for our project was nonvalidated, but its components have been previously used in the ophthalmology field [<xref ref-type="bibr" rid="ref20">20</xref>]. There is evidence to suggest acceptable reliability across a range of usability scales, from single to multi-item measures, suggesting that the underlying constructs are robustly captured even when item sets are modified for contextual fit [<xref ref-type="bibr" rid="ref21">21</xref>].</p><p>The statements were adapted from the MAUQ to focus on the image-capture workflow rather than a smartphone app, assessing 3 domains: ease of use, interface and satisfaction, and usefulness. Statements 1 to 2 of the survey covered &#x201C;ease of use,&#x201D; 3 to 5 addressed &#x201C;interface and satisfaction,&#x201D; and 6 to 7 focused on &#x201C;usefulness.&#x201D; The SUS and MAUQ were not applied as stand-alone validated instruments in their original scored form; instead, only selected items served as a conceptual source for usability framing and descriptive statistics. The use of single-item usability measures has been demonstrated to be equally reliable as more substantially itemed questionnaires [<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref22">22</xref>].</p><p>A 5-point Likert scale, adapted from the SUS, was included to provide a numerical measure for each subjective question, ranging from 1 to 5. An open-text box allowed for additional reflective comments from survey participants. The same survey was presented for each workflow. Price ranges were provided for each workflow to inform the response to statement 7, referring to cost-effectiveness. The survey also collected participants&#x2019; staff grades while maintaining full anonymity. Finally, a question at the end was provided to invite participants to opt into a semistructured interview for further discussion and reflection on ASP workflows.</p></sec><sec id="s2-6"><title>Data Collection</title><p>Surveys were disseminated within a single center. Participants were introduced to the project aims and given a brief tutorial on workflow operations to ensure consistent understanding, alongside a familiarity exercise. The evaluation focused on user experiences, both prior and novel, to provide a qualitative, quality-improvement perspective. Each workflow was trialed synchronously before survey completion, supporting experiential comparisons. Following survey completion, one-on-one interviews were conducted face-to-face or virtually via Zoom using an interview guide (<xref ref-type="supplementary-material" rid="app2">Multimedia Appendix 2</xref>), with verbal consent obtained for audio recording. Zoom interviews were offered to accommodate clinicians&#x2019; schedules rather than to selectively recruit technology-savvy participants.</p><p>To extend the analysis beyond usability and user preferences, the potential clinical applicability of ASP workflows was explored. This is particularly important given that many BYOD and ASP systems are increasingly designed not only for image acquisition but also to support clinical decision-making. Therefore, our project question in this regard was to ascertain what the clinical applications of these ASP workflows were with respect to clinical decision-making, specifically in informing diagnostic and monitoring decisions.</p><p>At the end of each interview, respondents were presented with a brief clinical case involving microbial keratitis, a common ophthalmic condition with potentially sight-threatening consequences if misdiagnosed or inadequately monitored. The condition was deliberately selected as a straightforward and common clinical scenario in which image quality may directly influence diagnostic confidence and longitudinal assessment. Participants were shown 4 unlabeled images of the same patient&#x2019;s eye, each captured using a different ASP workflow (<xref ref-type="fig" rid="figure2">Figure 2</xref>). Due to the visual nature of the ophthalmology specialty, diagnostic images were presented on printed A4 paper, and no additional clinical information or prompting was provided beyond the vignette.</p><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>A 21-year-old contact lens wearer presents to accident and emergency with pain and a red eye after sleeping in contact lenses overnight. These were the 4 clinical images that were available to project participants, each taken using a separate anterior segment photography (ASP) workflow and a clinical vignette: (A) NexYZ, (B) QuikVue, (C) Magnifier app, and (D) Zeiss Slit Lamp Imaging Solution. Image consent was obtained from the patient for research and project dissemination.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v10i1e89441_fig02.png"/></fig><p>Clinicians were asked to comment on image characteristics, identify relevant pathology, compare image quality between workflows, and match each image to its perceived source before answers were revealed. This exercise was designed to assess whether images obtained using different ASP workflows could provide sufficient information to support clinically meaningful decisions. With respect to the clinical utility scoring, participants were asked whether each image was adequate to inform a diagnostic or monitoring decision independently, or whether a conventional slit-lamp examination would still be required. This approach allowed the evaluation of the potential role of ASP workflows in supporting real-world clinical pathways beyond image capture alone.</p></sec><sec id="s2-7"><title>Data Analysis</title><p>The survey results were collated and analyzed in Microsoft Excel, and interviews were transcribed using Otter.ai and subsequently reviewed for accuracy by the authors (VN and YS-B). Consistent with the exploratory aims of this project, survey data were summarized descriptively; mean (SD) Likert-scale responses were calculated for each item, used to contextualize qualitative findings, and presented in a table. Additional comments from free-text boxes were thematically analyzed alongside interview transcripts using NVivo (Lumivero).</p><p>The use of means and SDs to summarize Likert-scale responses is a widely debated but commonly accepted practice in exploratory mixed methods studies [<xref ref-type="bibr" rid="ref23">23</xref>,<xref ref-type="bibr" rid="ref24">24</xref>]. Given the exploratory and quality improvement framing of our project, mean Likert-scale scores were intended as descriptive summaries to contextualize qualitative findings rather than as inferential statistics. These values summarize clinician perceptions of the complete imaging workflows and should be read as descriptive only. They are influenced by confounding factors, such as smartphone familiarity, capture software, and prior experience with BYOD governance, and are not intended to support statistical comparisons between ASP workflows. This is particularly relevant for the &#x201C;intention to use again&#x201D; domain, which is shaped by a clinician&#x2019;s existing familiarity with and acceptance of ASP rather than the imaging workflow alone. Formal hypothesis testing with statistical analysis was outside the scope of this evaluation, given the exploratory design and sample size.</p><p>The authorship team undertook a reflexive exercise prior to interviews, in which personal assumptions and positionalities were explicitly acknowledged as an active part of the analytical process; a predominantly constructivist research paradigm was adopted for the mixed methods project. All transcripts and comments were coded by a single author (VN); codes were iteratively developed into candidate subthemes, with those sharing analytical constructs consolidated into themes. This coding was then critically reviewed and interrogated by 2 authors (YS-B and RR) acting as &#x201C;critical friends,&#x201D; using an online mind-mapping process (Canva) to challenge and refine the developing themes rather than establishing intercoder agreement. This generative process of codes, subthemes, and themes reflects the interpretive flexibility of reflexive thematic analysis, wherein analytic constructs are understood to be author-generated and subject to human bias, rather than an inherent property of the data [<xref ref-type="bibr" rid="ref25">25</xref>,<xref ref-type="bibr" rid="ref26">26</xref>]. The thematic analysis reflects the mixed methods nature of our project, where interpretation of data is subjective, adopting a constructivist research paradigm.</p><p>The quantitative and qualitative components were analyzed and reported separately in the <italic>Results</italic> section. Likert-scale responses were summarized descriptively and were not incorporated into the thematic analysis. The only exception was that free-text survey comments were pooled with the interview transcripts and coded as a single qualitative dataset, so that both sources contributed to the same subthemes and themes. Descriptive Likert-scale ratings and qualitative themes were considered together at the discussion stage, where consistency between them supported an interpretation, and discrepancies were retained as reflecting variation in clinician experience.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Participant Recruitment and Interview Characteristics</title><p>A total of 35 residents and fellows were approached over a 4-week period, with 25 survey responses collected: 17 (68%) ophthalmology residents and 8 (32%) corneal fellows; 10 participants declined to participate due to timing constraints. Of this cohort, 16 expressed interest in an interview, and 12 interviews were completed (25% drop-out rate). The mean interview duration was 18.1 (SD 10.8) minutes.</p></sec><sec id="s3-2"><title>Survey Results</title><p>The survey data were first charted by collating Likert scale responses for each ASP workflow. Mean Likert scale response scores were calculated for each question and imaging workflow and are presented in <xref ref-type="table" rid="table1">Table 1</xref>. Clinician perceptions favored the Magnifier workflow, which received the highest ratings for usability, cost-effectiveness, and clinical utility (19/25, 76%, 23/25, 92%, and 18/25, 72% strongly agreed, respectively), with consistently favorable ratings across the evaluated domains.</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Mean Likert scale ratings of 4 anterior segment photography (ASP) workflows across 7 perception domains<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup><sup>,</sup><sup><xref ref-type="table-fn" rid="table1fn2">b</xref></sup>.</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="top">ASP workflow</td><td align="left" valign="top">Ease of use, mean (SD)</td><td align="left" valign="top">Ease of learning, mean (SD)</td><td align="left" valign="top">Design appeal, mean (SD)</td><td align="left" valign="top">Time efficiency, mean (SD)</td><td align="left" valign="top">Intention to use again, mean (SD)</td><td align="left" valign="top">Clinical utility, mean (SD)</td><td align="left" valign="top">Cost-effectiveness, mean (SD)</td></tr></thead><tbody><tr><td align="left" valign="top">Magnifier</td><td align="left" valign="top">4.68 (0.69)</td><td align="left" valign="top">4.72 (0.44)</td><td align="left" valign="top">4.44 (0.65)</td><td align="left" valign="top">4.72 (0.54)</td><td align="left" valign="top">4.44 (0.92)</td><td align="left" valign="top">4.68 (0.56)</td><td align="left" valign="top">4.92 (0.28)</td></tr><tr><td align="left" valign="top">QuikVue</td><td align="left" valign="top">4.28 (0.79)</td><td align="left" valign="top">4.44 (0.77)</td><td align="left" valign="top">4.16 (1.11)</td><td align="left" valign="top">4.16 (0.94)</td><td align="left" valign="top">4.16 (1.21)</td><td align="left" valign="top">4.48 (0.71)</td><td align="left" valign="top">2.96 (1.14)</td></tr><tr><td align="left" valign="top">NexYZ</td><td align="left" valign="top">3.28 (1.06)</td><td align="left" valign="top">3.92 (0.70)</td><td align="left" valign="top">3.20 (0.91)</td><td align="left" valign="top">3.24 (1.01)</td><td align="left" valign="top">3.28 (1.06)</td><td align="left" valign="top">3.88 (0.73)</td><td align="left" valign="top">4.12 (0.93)</td></tr><tr><td align="left" valign="top">ZSLIS<sup><xref ref-type="table-fn" rid="table1fn3">c</xref></sup></td><td align="left" valign="top">3.88 (0.78)</td><td align="left" valign="top">3.92 (0.91)</td><td align="left" valign="top">4.28 (0.68)</td><td align="left" valign="top">3.92 (0.91)</td><td align="left" valign="top">4.32 (0.85)</td><td align="left" valign="top">4.56 (0.58)</td><td align="left" valign="top">2.36 (1.08)</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>Values represented in this table are descriptive summaries of clinician perceptions of the complete imaging workflows and are not intended for statistical comparison between workflows, nor are they adjusted for confounding factors including workflow type, user familiarity, software, hardware adapters, and information governance.</p></fn><fn id="table1fn2"><p><sup>b</sup>Values presented as mean on a 5-point Likert scale, where higher scores indicate more favorable perceptions.</p></fn><fn id="table1fn3"><p><sup>c</sup>ZSLIS: Zeiss Slit Lamp Imaging Solution.</p></fn></table-wrap-foot></table-wrap></sec><sec id="s3-3"><title>Thematic Analysis</title><sec id="s3-3-1"><title>Theme 1: Obstacles to Clinical Implementation</title><p>The most frequently referenced theme was &#x201C;obstacles to clinical implementation,&#x201D; which encompassed challenges in integrating ASP workflows into practice. Although clinicians recognized the clinical value of these images, they consistently reported barriers, including design flaws, lengthy workflows, and limited accessibility.</p><p>Workflow limitations were a recurrent concern. The Magnifier workflow was constrained by smartphone camera quality and the absence of a cobalt-blue filter; the QuikVue workflow lacked a slit-beam, limiting full AS assessment. Clinically important features&#x2014;slit-beam illumination, wide-angle view, and adequate magnification&#x2014;were often inadequate. Design issues added to frustration: the QuikVue workflow was incompatible with some smartphones and prone to image distortion due to the nature of its native lens, while the NexYZ workflow was described as &#x201C;bulky&#x201D; and &#x201C;fiddly,&#x201D; reflecting its nonmedical design and time-consuming workflow to attach to a smartphone, followed by a slit-lamp. The ZSLIS workflow, too, presented difficulties, including a steep learning curve and suboptimal synchronization between its optical system and camera. Accessibility compounded these issues, with difficulties in sourcing and reliably locating the NexYZ and QuikVue, both of which were viewed as easily misplaced or borrowed by other departments when not attached to a smartphone, while the ZSLIS was considered prohibitively expensive and not readily available in many units.</p><p>Finally, a sense of discouragement emerged. Clinicians reported a reluctance to use ASP despite recognizing its benefits, citing practical irritations such as removing phone cases for the QuikVue workflow, the disproportionate setup time of the NexYZ workflow for a single image, and ZSLIS-related workflow disruption, which often required moving patients and transferring images through a separate computer system.</p><p>Taken together, these challenges created frustration that impeded widespread uptake. Of the workflows, the ZSLIS workflow posed the greatest obstacles, including high cost, lack of portability, workflow disruption, and training requirements, followed by the NexYZ workflow, which was criticized for its bulk and time-consuming setup. The QuikVue workflow faced issues of compatibility and limited functionality, while the Magnifier workflow, though restricted by smartphone quality and lacking a cobalt-blue filter, was viewed as presenting fewer barriers overall.</p></sec><sec id="s3-3-2"><title>Theme 2: Accessibility</title><p>Theme 2, &#x201C;accessibility,&#x201D; highlighted each workflow&#x2019;s positive attributes and potential to enhance practice, with 3 subthemes: ease of use, portability, and design. The Magnifier workflow was most praised, particularly in eye casualty, where equipment is often misplaced. Its integration with clinicians&#x2019; own smartphones removed the need for additional tools, making it suitable for wards and patients with limited mobility. Respondents valued its simplicity and speed. It was also effective in complex scenarios, such as pediatric cases, aided by rapid shutter speeds, although ultimately dependent on the smartphone.</p><p>The NexYZ workflow was commended for stability; once assembled, it required minimal adjustment for consistent imaging. Portability was another strength, with the Magnifier and QuikVue workflows frequently noted for compactness. The QuikVue workflow was described as &#x201C;probably the most portable,&#x201D; requiring no slit-lamp and easily attachable to smartphones for opportunistic imaging. Design features were also valued: the QuikVue workflow&#x2019;s built-in cobalt-blue light and the NexYZ workflow&#x2019;s ability to use slit-lamp optics supported detailed corneal assessment, offsetting earlier design criticisms.</p><p>Overall, the Magnifier workflow ranked highest for accessibility due to smartphone compatibility, ease of use, and versatility across settings. The QuikVue workflow followed, valued for portability and cobalt-blue light; the NexYZ workflow offered stability but required a slit-lamp and greater workflow time. The ZSLIS workflow ranked lowest, constrained by cost, bulk, and training demands.</p></sec><sec id="s3-3-3"><title>Theme 3: Quality and Workflow</title><p>Theme 3, &#x201C;quality and workflow,&#x201D; captures clinicians&#x2019; perspectives on ASP, focusing on image quality, uploading, and standardization. The ZSLIS workflow was consistently rated highest for image quality, particularly in monitoring slowly progressing conditions such as iris nevi or fungal infections, owing to its superior resolution and sophisticated camera optics.</p><p>Image upload proved problematic across all workflows. Smartphone-based uploads, the Magnifier, QuikVue, and NexYZ workflows, were viewed as inefficient and prone to delays due to login or connectivity issues, while the ZSLIS workflow&#x2019;s reliance on the proprietary Zeiss database often hindered image extraction. Image capture standardization was deemed essential for diagnostic consistency, follow-up, research, and AI use. Furthermore, the QuikVue and Magnifier workflows were praised for fixed focal lengths that promote standardization, though the Magnifier&#x2019;s design necessitated close proximity to the patient, sometimes causing discomfort.</p><p>For overall image capture, the ZSLIS workflow ranked highest for quality and clinical utility, followed by the NexYZ workflow for slit-lamp compatibility. The QuikVue workflow was ranked third for its standardization benefits and built-in lighting, while the Magnifier workflow ranked lowest, offering portability and ease of use at the cost of image quality.</p></sec><sec id="s3-3-4"><title>Theme 4: Digital Ethics</title><p>The use of personal devices introduces considerations for data protection and information governance (IG). Theme 4, &#x201C;digital ethics,&#x201D; explores the ethical and practical challenges associated with using personal devices in clinical settings, focusing on 2 subthemes: data protection and personal device use.</p><p>Respondents raised concerns about potential breaches of patient confidentiality when personal devices are used in clinical practice, particularly when connected to unsecured networks or when delays in uploading images introduce the risk of human error, with 1 participant detailing, &#x201C;the issue of, if you are using your own device, where are the images being saved?&#x201D; Participants highlighted a perceived tension between the convenience of digitally connected devices and confidence in the security of captured images. Notably, these concerns persisted despite the availability of established BYOD infrastructure and IG-compliant image-sharing solutions within the trust. Several respondents expressed uncertainty regarding image storage pathways, cloud connectivity, and the practical application of local BYOD policies, suggesting that a lack of governance awareness may represent a barrier to adoption independent of the governance frameworks themselves. This finding highlights that successful implementation of smartphone-based ASP workflows may require not only robust governance systems but also clinician understanding and confidence in those systems.</p><p>The use of personal devices further raised issues relating to professionalism, infection control, and standardization, given the variability in device types and clinician preferences. Moreover, patient perceptions of clinicians using personal phones for clinical photography were identified as a potentially sensitive issue. Although MEH offers access to Pando, an IG-compliant platform for secure image sharing, these broader ethical and procedural considerations highlight the complexity of integrating personal technology into routine clinical practice.</p><p>MEH has its own distinct BYOD network to facilitate BYOD photography, with dedicated EPR integration. The views expressed by respondents, therefore, appear to reflect uncertainty surrounding the practical implementation and understanding of BYOD governance, rather than deficiencies in the trust&#x2019;s existing governance infrastructure.</p></sec><sec id="s3-3-5"><title>Theme 5: Innovation</title><p>Theme 5, &#x201C;innovation,&#x201D; captures clinicians&#x2019; aspirations for advancing ASP through streamlined, purpose-built solutions. Respondents expressed a desire for an app that fully uses the smartphone&#x2019;s camera features, avoids saving images to the device&#x2019;s camera roll, and automatically uploads them to the EPR, thereby enhancing efficiency and maintaining IG compliance. Among those who did not mention an all-in-one application, many discussed the idea of an all-in-one slit-lamp, integrated with immediate photography and uploading capabilities that maintain IG compliance and image quality.</p><p>Together, these ideas reflect a clear clinician desire for image capture technologies that simplify clinical workflows while improving on current clinical standards.</p><p>A summary map of the thematic analysis results, a visual representation of the emerging subthemes and how they are collapsed into themes, can be found in <xref ref-type="fig" rid="figure3">Figure 3</xref>.</p><fig position="float" id="figure3"><label>Figure 3.</label><caption><p>A map chart detailing the 5 key themes (obstacles to clinical implementation, accessibility, quality and workflow, digital ethics, and innovation) that arose from thematic analysis of interview transcripts and free-text comments from surveys, and the subthemes that are interconnected.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v10i1e89441_fig03.png"/></fig></sec></sec><sec id="s3-4"><title>Additional Findings</title><p>Interview respondents were asked about their preferred ASP workflow in the context of clinical utility, assessed through a review of captured images from a clinical case of microbial keratitis. The respondents&#x2019; preferences also included a subjective summation of usability aspects, as explored through thematic analysis and surveys. It was revealed that the majority preferred the Magnifier workflow. <xref ref-type="table" rid="table2">Table 2</xref> shows overall preferences in a clinical utility context, though these findings reflect clinician-perceived clinical utility based on a single illustrative case.</p><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Ophthalmology residents and corneal fellows&#x2019; favorite anterior segment photography (ASP) workflows by percentage in the context of clinical utility when presented with images of a microbial keratitis case (N=12).</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">ASP workflow</td><td align="left" valign="bottom">Respondents expressing preference, n (%)</td></tr></thead><tbody><tr><td align="left" valign="top">Magnifier</td><td align="left" valign="top">5 (42)</td></tr><tr><td align="left" valign="top">QuikVue</td><td align="left" valign="top">2 (17)</td></tr><tr><td align="left" valign="top">NexYZ</td><td align="left" valign="top">3 (25)</td></tr><tr><td align="left" valign="top">ZSLIS<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup></td><td align="left" valign="top">2 (17)</td></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>ZSLIS: Zeiss Slit Lamp Imaging Solution.</p></fn></table-wrap-foot></table-wrap></sec><sec id="s3-5"><title>Clinical Case Discussion</title><p>When presented with images of a corneal infiltrate from the clinical case of microbial keratitis, all respondents identified the correct clinical diagnosis and localized it to the appropriate region of the cornea. Across workflows, variation was observed in global image characteristics such as field of view, depth of field, resolution, illumination, and the presence of reflections. For example, the Magnifier image encompassed the entire globe, allowing appreciation of conjunctival injection in addition to a faint outline of the infiltrate. The QuikVue image demonstrated higher magnification, but was limited by prominent reflections, reducing structural visibility. The NexYZ image, while also highly magnified and lacking conjunctival context, conveyed greater information about the depth of the lesion. The ZSLIS image offered the highest resolution, with fine adnexal detail, though uneven illumination introduced shadowing at the lesion site.</p><p>When explored in interviews, clinician preferences reflected these differing characteristics: the NexYZ workflow was selected as the most informative for diagnostic purposes (n=5, 42%), while the Magnifier workflow was most frequently identified as the second most useful (n=4, 33%). It should be emphasized that these results highlight a preference for the ASP workflow in the context of producing a diagnostically informative image during interviews, rather than an objective diagnostic accuracy assessment.</p></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><p>This mixed methods evaluation explored 4 ASP workflows and clinicians&#x2019; perceptions of their clinical utility. Clinicians highlighted the value of ASP in documentation, referrals, and monitoring, though no single workflow emerged as universally optimal. This likely reflects that the clinical context and the purpose of image acquisition influence which ASP approach is most appropriate on a case-by-case basis. The Magnifier workflow scored highest for usability, clinical utility, and cost-effectiveness. The QuikVue workflow was rated positively for usability but criticized for its cost, incompatibility with certain smartphone models, and challenges in capturing certain pathologies. The NexYZ and ZSLIS workflows received mixed feedback, with some concerns about usability, although their contribution to clinical assessment was acknowledged.</p><p>There are several existing studies that explore ASP workflows with some overlapping findings with this project. Pujari et al [<xref ref-type="bibr" rid="ref27">27</xref>] evaluated a smartphone clip-on device like QuikVue without examining clinical integration. Similarly, Aswin [<xref ref-type="bibr" rid="ref28">28</xref>] described using a smartphone with a slit-beam adjunct for AS imaging, presenting a different approach that could be combined with the Magnifier app. A study by Mamtora et al [<xref ref-type="bibr" rid="ref4">4</xref>] shared similar objectives to this project, where there was a focus on a single ASP workflow (QuikVue) that could improve HES referrals to eye care services. Mamtora et al [<xref ref-type="bibr" rid="ref4">4</xref>] captured both cobalt-blue and white-light images for different AS pathologies; their narrower research question and comparison of only one device provided valuable background for this project.</p><p>Beyond singular device-specific evaluations, our findings resonate with a growing body of work on smartphone slit-lamp imaging. In a noninferiority study, Goel et al [<xref ref-type="bibr" rid="ref29">29</xref>] found that ASP images captured on a smartphone coupled to a slit-lamp adapter were subjectively noninferior to those from a commercial built-in slit-lamp camera, as judged across all grades of ophthalmic staff. Muth et al [<xref ref-type="bibr" rid="ref30">30</xref>] similarly reported that a smartphone slit-lamp adapter produced high-quality AS images and was faster for image acquisition than a dedicated ophthalmic photographer, concluding that such setups offer a cost-effective, portable solution to support documentation and communication between colleagues. The usability dimension our project explores is likewise reflected in the wider literature; Emam et al [<xref ref-type="bibr" rid="ref31">31</xref>] demonstrated ease of use in an ASP-naive medical student cohort following a brief hands-on instructional course. Our project advances this body of work in 3 respects: comparing multiple imaging workflows within a single clinical service rather than evaluating 1 adapter in isolation; embedding the evaluation in a real-world clinical example rather than controlled image-capture tasks; and pairing quantitative ratings with qualitative methods to triangulate the themes that shape ASP workflow implementation in clinical practice.</p><p>Alongside these contributions, our survey and interview data indicated barriers to adoption, particularly the administrative burden of documentation and integration with EPR systems. Evidence suggests such documentation pressures contribute to cognitive overload and burnout [<xref ref-type="bibr" rid="ref32">32</xref>]. The Magnifier workflow&#x2019;s popularity may therefore reflect its simplicity and compatibility with existing smartphone infrastructure, especially valuable in eye casualty, where rapid image capture can complement written notes. The NexYZ workflow was viewed as more useful in corneal clinics, leveraging slit-lamp optics for detailed layer-by-layer assessment using the crossbeam function and video recording, allowing for dynamic appreciation and documentation of pathology. The QuikVue workflow, though less suited to corneal pathology due to glare, was appreciated for its cobalt-blue illumination and portability, making it relevant in community or emergency settings where slit-lamp access is limited.</p><p>Evidence indicates that there is a growing movement toward telemedicine in eye health care services and that an estimated 98% of health care personnel own personal smartphones [<xref ref-type="bibr" rid="ref33">33</xref>]. The General Medical Council (GMC) guidance on capturing clinical images emphasizes patient consent, with storage policies varying by trust [<xref ref-type="bibr" rid="ref34">34</xref>]. This creates ambiguity where trusts lack specific policies for BYOD photography, or where variation exists in the wider health care system. Clinician interviews provided insights into IG compliance and BYOD policies, noting that the Magnifier workflow enables secure sharing by compartmentalizing images without uploading to the smartphone&#x2019;s image gallery. However, a key barrier to widespread BYOD adoption may be the lack of clear guidance and organizational knowledge of approved and standardized approaches to BYOD photography. Concerns were also raised about biometric data safety, particularly as iris images are increasingly used in recognition technologies, underscoring the need for broader safety considerations [<xref ref-type="bibr" rid="ref35">35</xref>].</p><p>Beyond immediate clinical use, respondents noted potential benefits for education, training, and AI development. By embedding images directly into referral correspondence, digital ASP could improve referral quality and efficiency, support intrahospital discussion, and facilitate team-based decision-making with minimal disruption. These findings align with wider shifts toward telemedicine and digital ophthalmology [<xref ref-type="bibr" rid="ref6">6</xref>]. The literature shows that including AS images with referrals enhances diagnostic accuracy over written histories alone, and smartphone-acquired images are increasingly positioned within teleophthalmology pathways that connect nonspecialists or remote practitioners with tertiary corneal services through automated image triaging [<xref ref-type="bibr" rid="ref4">4</xref>,<xref ref-type="bibr" rid="ref36">36</xref>]. The trajectory toward AI integration and AI-assisted clinical pathways lends weight to these ASP workflows. Deep-learning models have demonstrated the ability to classify and differentiate between AS conditions, including infectious keratitis and its causative organisms, directly from smartphone-acquired images [<xref ref-type="bibr" rid="ref37">37</xref>,<xref ref-type="bibr" rid="ref38">38</xref>]. Notably, Maehara et al [<xref ref-type="bibr" rid="ref38">38</xref>] used images captured on the iPhone 13 Pro, the same as in this present project, and demonstrated diagnostic accuracy comparable to slit-lamp images when interpreted with AI assistance [<xref ref-type="bibr" rid="ref38">38</xref>]. These findings highlight the wider shift toward AI-augmented pathways in conventional telemedicine and digital ophthalmology.</p><p>This project had several limitations. First, the 4 workflows represent different ASP categories that differ in purpose, setup, portability, and workflow requirements. The findings should, therefore, be read as a real-world exploration of clinician experience rather than a head-to-head technical comparison. The ZSLIS workflow, in particular, required a separate cubicle and dedicated imaging setup, which may have shaped perceptions of accessibility and workflow integration. As an exploratory quality-improvement evaluation, the project was not designed or powered for hypothesis testing, and quantitative findings are presented descriptively.</p><p>Second, the clinical case component should be interpreted cautiously. It used a single illustrative case to contextualize clinician-perceived image utility rather than to evaluate workflow performance, and image quality in this setting may reflect both the technical properties of each workflow and how it was used on that day. We did not objectively measure diagnostic accuracy, workflow time, downstream clinical impact, or image quality against standardized grading criteria.</p><p>Finally, several sources of bias should be acknowledged. Participants varied in prior familiarity with smartphone-based photography, reflecting general rather than workflow-specific experience. Unequal familiarity with the individual components of each workflow may also have influenced perceptions despite standardized tutorials. Voluntary participation introduces possible self-selection toward clinicians with greater interest in digital imaging. All participants completed the survey immediately after hands-on use under identical conditions; however, interviews were conducted both face-to-face and via Zoom to accommodate schedules, which may have introduced response bias. Consistent with reflexive thematic analysis, coding was undertaken by a single author, with structured critical review by 2 others to mitigate sole-coder bias. The single-center setting, small sample, and resident or fellow cohort further limit generalizability to other settings and health care systems.</p><p>This evaluation focused on clinician experience in corneal and eye casualty settings. Future research should therefore evaluate integration into referral and triage pathways, formal cost analyses, comparisons between AS videography and photography, objective measures of image quality and workflow efficiency, and the impact of ASP on clinical decision-making and patient outcomes. Future studies should also focus on using standardized acquisition protocols, masked grading, timed workflow assessment, and an appropriate diagnostic reference standard. Patient perceptions of smartphone use in clinical settings also require attention. While smartphone photography offers clear benefits, some patients may perceive it as unprofessional [<xref ref-type="bibr" rid="ref39">39</xref>]. Further research is necessary to explore patient views on ophthalmic photography and its implications for clinical practice.</p><p>In an era of expanding telemedicine, smartphone use, and AI-based decision support tools, ASP is likely to play an increasing role in clinical workflows. Within corneal and eye casualty settings at a single tertiary center, this evaluation did not identify a single optimal ASP workflow. Most respondents expressed a preference for the Magnifier workflow, which may reflect its ease of use, interface, cost, and integration with existing smartphone infrastructure. Our findings suggest that dedicated guidelines, documentation systems, and educational resources may help clinicians capture standardized images while safeguarding patient data, though this warrants further evaluation. Finally, understanding patient perspectives remains critical for ensuring that digital ASP enhances, rather than undermines, the quality of ophthalmic care.</p></sec></body><back><ack><p>The authors would like to thank Charles Hennings for donating a QuikVue device to this project and for sharing his expertise in BYOD (bring your own device) photography. Dr Charles Hennings had no role in project design, data collection, analysis, interpretation, manuscript preparation, or publication decisions; his technical input was provided prior to the project period. The team would also like to thank Dr Charlotte Ho, Dr Medhavini Dissanayaka, and Dr Caroline Kilduff for their support throughout the data collection period. The authors declare the use of generative AI (GenAI) during project execution and the writing process. According to the Generative AI Delegation Taxonomy (GAIDeT, 2025), the following tasks were delegated to GenAI tools under full human supervision: data organization and publication support. The GenAI tools used were as follows: ChatGPT (version 4.5; OpenAI) and Otter.ai. ChatGPT was used to assist with drafting the cover letter and refining manuscript phrasing, including US English grammar and language checks. Otter.ai was used to transcribe audio recordings, which were then manually coded. To ensure transcription fidelity, each transcript underwent manual verification against the original audio recording by a team member (VN). Any inaccuracies, omissions, or misattributed speech were corrected prior to the formal reflexive thematic analysis. As GenAI outputs can vary between instances, all AI-assisted outputs were checked and verified by the first author (VN). No AI-assisted output was used without this manual confirmation. Responsibility for the final manuscript lies entirely with the authors. GenAI tools are not listed as authors and bear no responsibility for the final content. The reflexive thematic analysis, interpretation of findings, and all applicable scientific conclusions were performed solely by the human authorship team.</p></ack><notes><sec><title>Funding</title><p>The authors declared no financial support was received for this work.</p></sec><sec><title>Data Availability</title><p>All data generated or analyzed during this project are included in this published article and its supplementary information files.</p></sec></notes><fn-group><fn fn-type="con"><p>VN collected data, performed data analysis, and drafted the manuscript. YS-B contributed to project design and recruitment, provided expertise regarding thematic analysis, and critically revised the manuscript. EJ provided clinical expertise and critically evaluated the manuscript. RR conceived the project, contributed to the interpretation of results, supervised the project, provided critical feedback, and guided the research and analysis. All authors reviewed and approved the final version of the manuscript.</p></fn><fn fn-type="conflict"><p>None declared.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">AS</term><def><p>anterior segment</p></def></def-item><def-item><term id="abb2">ASP</term><def><p>anterior segment photography</p></def></def-item><def-item><term id="abb3">BYOD</term><def><p>Bring Your Own Device</p></def></def-item><def-item><term id="abb4">EPR</term><def><p>electronic patient record</p></def></def-item><def-item><term id="abb5">GDPR</term><def><p>General Data Protection Regulation</p></def></def-item><def-item><term id="abb6">GMC</term><def><p>General Medical Council</p></def></def-item><def-item><term id="abb7">HES</term><def><p>Hospital Eye Services</p></def></def-item><def-item><term id="abb8">IG</term><def><p>information governance</p></def></def-item><def-item><term id="abb9">MAUQ</term><def><p>mHealth App Usability Questionnaire</p></def></def-item><def-item><term id="abb10">MEH</term><def><p>Moorfields Eye Hospital</p></def></def-item><def-item><term id="abb11">NHS</term><def><p>National Health Service</p></def></def-item><def-item><term id="abb12">QIP</term><def><p>quality-improvement project</p></def></def-item><def-item><term id="abb13">SUS</term><def><p>System Usability Scale</p></def></def-item><def-item><term id="abb14">ZSLIS</term><def><p>Zeiss Slit Lamp Imaging Solution</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="web"><article-title>The Eyes Have It coalition calls for the next government to prioritise eye care</article-title><source>RNIB (Royal National Institute of Blind People)</source><access-date>2025-08-31</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.rnib.org.uk/news/the-eyes-have-it-coalition-calls-for-the-next-government-to-prioritise-eye-care/">https://www.rnib.org.uk/news/the-eyes-have-it-coalition-calls-for-the-next-government-to-prioritise-eye-care/</ext-link></comment></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="web"><article-title>RCOphth calls for action on workforce to reduce strain on ophthalmology services</article-title><source>The Royal College of Ophthalmologists</source><access-date>2025-08-31</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://curriculum.rcophth.ac.uk/2021/09/rcophth-calls-for-action-on-workforce-to-reduce-strain/">https://curriculum.rcophth.ac.uk/2021/09/rcophth-calls-for-action-on-workforce-to-reduce-strain/</ext-link></comment></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="report"><article-title>Ophthalmic service guidance emergency eye care in hospital eye units and secondary care</article-title><year>2024</year><access-date>2025-08-31</access-date><publisher-name>The Royal College of Ophthalmologists (RCOphth)</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://www.rcophth.ac.uk/wp-content/uploads/2026/06/Emergency-eye-care-in-hospital-eye-units-and-secondary-care.pdf">https://www.rcophth.ac.uk/wp-content/uploads/2026/06/Emergency-eye-care-in-hospital-eye-units-and-secondary-care.pdf</ext-link></comment></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mamtora</surname><given-names>S</given-names> </name><name name-style="western"><surname>Riley</surname><given-names>O</given-names> </name><name name-style="western"><surname>Chervenkoff</surname><given-names>J</given-names> </name><etal/></person-group><article-title>A smartphone lens attachment improves the quality of referrals to eye casualty</article-title><source>Eye (Lond)</source><year>2023</year><month>06</month><volume>37</volume><issue>9</issue><fpage>1885</fpage><lpage>1889</lpage><pub-id pub-id-type="doi">10.1038/s41433-022-02233-w</pub-id><pub-id pub-id-type="medline">36167983</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Srinivasan</surname><given-names>M</given-names> </name><name name-style="western"><surname>Mascarenhas</surname><given-names>J</given-names> </name><name name-style="western"><surname>Prashanth</surname><given-names>CN</given-names> </name></person-group><article-title>Distinguishing infective versus noninfective keratitis</article-title><source>Indian J Ophthalmol</source><year>2008</year><volume>56</volume><issue>3</issue><fpage>203</fpage><lpage>207</lpage><pub-id pub-id-type="doi">10.4103/0301-4738.40358</pub-id><pub-id pub-id-type="medline">18417820</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cao</surname><given-names>B</given-names> </name><name name-style="western"><surname>Vu</surname><given-names>CHV</given-names> </name><name name-style="western"><surname>Keenan</surname><given-names>JD</given-names> </name></person-group><article-title>Telemedicine for cornea and external disease: a scoping review of imaging devices</article-title><source>Ophthalmol Ther</source><year>2023</year><month>10</month><volume>12</volume><issue>5</issue><fpage>2281</fpage><lpage>2293</lpage><pub-id pub-id-type="doi">10.1007/s40123-023-00764-3</pub-id><pub-id pub-id-type="medline">37458978</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="web"><article-title>Magnifier</article-title><source>Apple App Store</source><access-date>2026-06-13</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://apps.apple.com/us/app/magnifier/id1563316278">https://apps.apple.com/us/app/magnifier/id1563316278</ext-link></comment></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="report"><article-title>Smartphone eye imaging adaptor: QuikVue&#x00AE; VPA-100</article-title><year>2018</year><access-date>2026-06-13</access-date><publisher-name>Shanghai VisuScience Meditech Co., Ltd</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://eurotechoptical.com/images/products/visu-science/QuikVue-Smartphone-Eye-Imaging_Adaptor.pdf">https://eurotechoptical.com/images/products/visu-science/QuikVue-Smartphone-Eye-Imaging_Adaptor.pdf</ext-link></comment></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="web"><article-title>NexYZ 3-Axis Universal Smartphone Adapter</article-title><source>Celestron</source><access-date>2026-06-13</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.celestron.com/products/nexyz-3-axis-universal-smartphone-adapter">https://www.celestron.com/products/nexyz-3-axis-universal-smartphone-adapter</ext-link></comment></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="web"><article-title>ZEISS SL imaging solution: seamless image and data capture for slit lamps</article-title><source>ZEISS Medical Technology</source><access-date>2026-06-13</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.zeiss.com/meditec/en/products/basic-diagnostic-devices/zeiss-slit-lamps/zeiss-sl-imaging-solution.html">https://www.zeiss.com/meditec/en/products/basic-diagnostic-devices/zeiss-slit-lamps/zeiss-sl-imaging-solution.html</ext-link></comment></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="web"><article-title>iPhone 13 Pro - Technical Specifications</article-title><source>Apple Documentation</source><access-date>2026-07-14</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://support.apple.com/en-gb/111871">https://support.apple.com/en-gb/111871</ext-link></comment></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="report"><article-title>Defining research, service evaluation, audit and health surveillance</article-title><year>2022</year><access-date>2026-06-13</access-date><publisher-name>Health Research Authority (HRA)</publisher-name><comment><ext-link ext-link-type="uri" xlink:href="https://www.hra-decisiontools.org.uk/research/docs/DefiningResearchTable_Oct2022.pdf">https://www.hra-decisiontools.org.uk/research/docs/DefiningResearchTable_Oct2022.pdf</ext-link></comment></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="web"><article-title>Data Protection Act 2018</article-title><source>legislation.gov.uk</source><year>2018</year><access-date>2026-06-22</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.legislation.gov.uk/ukpga/2018/12/contents">https://www.legislation.gov.uk/ukpga/2018/12/contents</ext-link></comment></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="web"><article-title>Bring your own device (BYOD)</article-title><source>NHS England Digital</source><access-date>2026-06-13</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://digital.nhs.uk/data-and-information/information-governance/guidance/bring-your-own-device-byod-guidance">https://digital.nhs.uk/data-and-information/information-governance/guidance/bring-your-own-device-byod-guidance</ext-link></comment></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Guest</surname><given-names>G</given-names> </name><name name-style="western"><surname>Bunce</surname><given-names>A</given-names> </name><name name-style="western"><surname>Johnson</surname><given-names>L</given-names> </name></person-group><article-title>How many interviews are enough?</article-title><source>Field methods</source><year>2006</year><month>02</month><volume>18</volume><issue>1</issue><fpage>59</fpage><lpage>82</lpage><pub-id pub-id-type="doi">10.1177/1525822X05279903</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Zhou</surname><given-names>AW</given-names> </name><name name-style="western"><surname>Noble</surname><given-names>J</given-names> </name><name name-style="western"><surname>Lam</surname><given-names>WC</given-names> </name></person-group><article-title>Canadian ophthalmology residency training: an evaluation of resident satisfaction and comparison with international standards</article-title><source>Can J Ophthalmol</source><year>2009</year><month>10</month><volume>44</volume><issue>5</issue><fpage>540</fpage><lpage>547</lpage><pub-id pub-id-type="doi">10.3129/i09-155</pub-id><pub-id pub-id-type="medline">19789589</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kloek</surname><given-names>CE</given-names> </name><name name-style="western"><surname>Borboli-Gerogiannis</surname><given-names>S</given-names> </name><name name-style="western"><surname>Chang</surname><given-names>K</given-names> </name><etal/></person-group><article-title>A broadly applicable surgical teaching method: evaluation of a stepwise introduction to cataract surgery</article-title><source>J Surg Educ</source><year>2014</year><volume>71</volume><issue>2</issue><fpage>169</fpage><lpage>175</lpage><pub-id pub-id-type="doi">10.1016/j.jsurg.2013.07.007</pub-id><pub-id pub-id-type="medline">24602704</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Brooke</surname><given-names>J</given-names> </name></person-group><person-group person-group-type="editor"><name name-style="western"><surname>Jordan</surname><given-names>PW</given-names> </name><name name-style="western"><surname>Thomas</surname><given-names>B</given-names> </name><name name-style="western"><surname>McClelland</surname><given-names>IL</given-names> </name><name name-style="western"><surname>Weerdmeester</surname><given-names>BA</given-names> </name></person-group><article-title>SUS - a quick and dirty usability scale</article-title><source>Usability Evaluation In Industry</source><year>1996</year><publisher-name>CRC Press</publisher-name><fpage>207</fpage><lpage>212</lpage><pub-id pub-id-type="doi">10.1201/9781498710411-35</pub-id><pub-id pub-id-type="other">9781498710411</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chumkasian</surname><given-names>W</given-names> </name><name name-style="western"><surname>Fernandez</surname><given-names>R</given-names> </name><name name-style="western"><surname>Win</surname><given-names>KT</given-names> </name><name name-style="western"><surname>Petsoglou</surname><given-names>C</given-names> </name><name name-style="western"><surname>Lord</surname><given-names>H</given-names> </name></person-group><article-title>Adaptation of the MAUQ and usability evaluation of a mobile phone-based system to promote eye donation</article-title><source>Int J Med Inform</source><year>2021</year><month>07</month><volume>151</volume><fpage>104462</fpage><pub-id pub-id-type="doi">10.1016/j.ijmedinf.2021.104462</pub-id><pub-id pub-id-type="medline">33933903</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Dave</surname><given-names>S</given-names> </name><name name-style="western"><surname>Rathore</surname><given-names>M</given-names> </name><name name-style="western"><surname>Campbell</surname><given-names>P</given-names> </name><etal/></person-group><article-title>Views and opinions of patients with glaucoma and age-related macular degeneration on vision home-monitoring: a UK-based focus group study</article-title><source>BMJ Open</source><year>2024</year><month>07</month><day>13</day><volume>14</volume><issue>7</issue><fpage>e080619</fpage><pub-id pub-id-type="doi">10.1136/bmjopen-2023-080619</pub-id><pub-id pub-id-type="medline">39002965</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sauro</surname><given-names>J</given-names> </name><name name-style="western"><surname>Dumas</surname><given-names>JS</given-names> </name></person-group><article-title>Comparison of three one-question, post-task usability questionnaires</article-title><source>Proc SIGCHI Conf Hum Factors Comput Syst</source><year>2009</year><month>04</month><day>4</day><fpage>1599</fpage><lpage>1608</lpage><pub-id pub-id-type="doi">10.1145/1518701.1518946</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Christophersen</surname><given-names>T</given-names> </name><name name-style="western"><surname>Konradt</surname><given-names>U</given-names> </name></person-group><article-title>Reliability, validity, and sensitivity of a single-item measure of online store usability</article-title><source>Int J Hum Comput Stud</source><year>2011</year><month>04</month><volume>69</volume><issue>4</issue><fpage>269</fpage><lpage>280</lpage><pub-id pub-id-type="doi">10.1016/j.ijhcs.2010.10.005</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sullivan</surname><given-names>GM</given-names> </name><name name-style="western"><surname>Artino</surname><given-names>AR</given-names> </name></person-group><article-title>Analyzing and interpreting data from Likert-type scales</article-title><source>J Grad Med Educ</source><year>2013</year><month>12</month><volume>5</volume><issue>4</issue><fpage>541</fpage><lpage>542</lpage><pub-id pub-id-type="doi">10.4300/JGME-5-4-18</pub-id><pub-id pub-id-type="medline">24454995</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Norman</surname><given-names>G</given-names> </name></person-group><article-title>Likert scales, levels of measurement and the &#x201C;laws&#x201D; of statistics</article-title><source>Adv Health Sci Educ Theory Pract</source><year>2010</year><month>12</month><volume>15</volume><issue>5</issue><fpage>625</fpage><lpage>632</lpage><pub-id pub-id-type="doi">10.1007/s10459-010-9222-y</pub-id><pub-id pub-id-type="medline">20146096</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hole</surname><given-names>L</given-names> </name></person-group><article-title>Handle with care; considerations of Braun and Clarke&#x2019;s approach to thematic analysis</article-title><source>Qual Res J</source><year>2024</year><month>06</month><day>25</day><volume>24</volume><issue>4</issue><fpage>371</fpage><lpage>383</lpage><pub-id pub-id-type="doi">10.1108/QRJ-08-2023-0132</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Braun</surname><given-names>V</given-names> </name><name name-style="western"><surname>Clarke</surname><given-names>V</given-names> </name></person-group><article-title>Using thematic analysis in psychology</article-title><source>Qual Res Psychol</source><year>2006</year><month>01</month><volume>3</volume><issue>2</issue><fpage>77</fpage><lpage>101</lpage><pub-id pub-id-type="doi">10.1191/1478088706qp063oa</pub-id></nlm-citation></ref><ref id="ref27"><label>27</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Pujari</surname><given-names>A</given-names> </name><name name-style="western"><surname>Mukhija</surname><given-names>R</given-names> </name><name name-style="western"><surname>Singh</surname><given-names>AB</given-names> </name><name name-style="western"><surname>Chawla</surname><given-names>R</given-names> </name><name name-style="western"><surname>Sharma</surname><given-names>N</given-names> </name><name name-style="western"><surname>Kumar</surname><given-names>A</given-names> </name></person-group><article-title>Smartphone-based high definition anterior segment photography</article-title><source>Indian J Ophthalmol</source><year>2018</year><month>09</month><volume>66</volume><issue>9</issue><fpage>1375</fpage><lpage>1376</lpage><pub-id pub-id-type="doi">10.4103/ijo.IJO_544_18</pub-id><pub-id pub-id-type="medline">30127180</pub-id></nlm-citation></ref><ref id="ref28"><label>28</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Aswin</surname><given-names>PR</given-names> </name></person-group><article-title>Smartphone anterior segment photography with slit-lamp assisted illumination</article-title><source>Indian J Ophthalmol</source><year>2020</year><month>10</month><volume>68</volume><issue>10</issue><fpage>2249</fpage><pub-id pub-id-type="doi">10.4103/ijo.IJO_444_20</pub-id><pub-id pub-id-type="medline">32971667</pub-id></nlm-citation></ref><ref id="ref29"><label>29</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Goel</surname><given-names>R</given-names> </name><name name-style="western"><surname>Macri</surname><given-names>C</given-names> </name><name name-style="western"><surname>Bahrami</surname><given-names>B</given-names> </name><name name-style="western"><surname>Casson</surname><given-names>R</given-names> </name><name name-style="western"><surname>Chan</surname><given-names>WO</given-names> </name></person-group><article-title>Assessing the subjective quality of smartphone anterior segment photography: a non-inferiority study</article-title><source>Int Ophthalmol</source><year>2023</year><month>02</month><volume>43</volume><issue>2</issue><fpage>403</fpage><lpage>410</lpage><pub-id pub-id-type="doi">10.1007/s10792-022-02437-9</pub-id><pub-id pub-id-type="medline">36018419</pub-id></nlm-citation></ref><ref id="ref30"><label>30</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Muth</surname><given-names>DR</given-names> </name><name name-style="western"><surname>Blaser</surname><given-names>F</given-names> </name><name name-style="western"><surname>Foa</surname><given-names>N</given-names> </name><etal/></person-group><article-title>Smartphone slit lamp imaging-usability and quality assessment</article-title><source>Diagnostics (Basel)</source><year>2023</year><month>01</month><day>24</day><volume>13</volume><issue>3</issue><fpage>423</fpage><pub-id pub-id-type="doi">10.3390/diagnostics13030423</pub-id><pub-id pub-id-type="medline">36766528</pub-id></nlm-citation></ref><ref id="ref31"><label>31</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Emam</surname><given-names>MM</given-names> </name><name name-style="western"><surname>Alharbi</surname><given-names>MA</given-names> </name><name name-style="western"><surname>Alammar</surname><given-names>A</given-names> </name><etal/></person-group><article-title>Medical students&#x2019; perspectives regarding the use of a slit-lamp smartphone adapter for clinical slit-lamp photography</article-title><source>Cureus</source><year>2024</year><month>04</month><volume>16</volume><issue>4</issue><fpage>e57986</fpage><pub-id pub-id-type="doi">10.7759/cureus.57986</pub-id><pub-id pub-id-type="medline">38606028</pub-id></nlm-citation></ref><ref id="ref32"><label>32</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Asgari</surname><given-names>E</given-names> </name><name name-style="western"><surname>Kaur</surname><given-names>J</given-names> </name><name name-style="western"><surname>Nuredini</surname><given-names>G</given-names> </name><etal/></person-group><article-title>Impact of electronic health record use on cognitive load and burnout among clinicians: narrative review</article-title><source>JMIR Med Inform</source><year>2024</year><month>04</month><day>12</day><volume>12</volume><fpage>e55499</fpage><pub-id pub-id-type="doi">10.2196/55499</pub-id><pub-id pub-id-type="medline">38607672</pub-id></nlm-citation></ref><ref id="ref33"><label>33</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Nair</surname><given-names>AA</given-names> </name><name name-style="western"><surname>Afroz</surname><given-names>S</given-names> </name><name name-style="western"><surname>Ahmed</surname><given-names>BU</given-names> </name><etal/></person-group><article-title>Smartphone usage among doctors in the clinical setting in two culturally distinct countries: cross-sectional comparative study</article-title><source>JMIR mHealth uHealth</source><year>2021</year><month>05</month><day>10</day><volume>9</volume><issue>5</issue><fpage>e22599</fpage><pub-id pub-id-type="doi">10.2196/22599</pub-id><pub-id pub-id-type="medline">33970119</pub-id></nlm-citation></ref><ref id="ref34"><label>34</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><collab>General Medical Council</collab></person-group><article-title>Making and using visual and audio recordings of patients (May 2002)</article-title><source>J Audiov Media Med</source><year>2002</year><month>12</month><volume>25</volume><issue>4</issue><fpage>165</fpage><lpage>167</lpage><pub-id pub-id-type="doi">10.1080/0140511021000051162</pub-id><pub-id pub-id-type="medline">12554297</pub-id></nlm-citation></ref><ref id="ref35"><label>35</label><nlm-citation citation-type="web"><article-title>Types of biometrics: eye: iris &#x2013; use cases</article-title><source>Biometrics Institute</source><year>2022</year><access-date>2025-08-31</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.biometricsinstitute.org/types-of-biometrics-eye-iris-use-cases/">https://www.biometricsinstitute.org/types-of-biometrics-eye-iris-use-cases/</ext-link></comment></nlm-citation></ref><ref id="ref36"><label>36</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Jin</surname><given-names>K</given-names> </name><name name-style="western"><surname>Li</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Wu</surname><given-names>H</given-names> </name><etal/></person-group><article-title>Integration of smartphone technology and artificial intelligence for advanced ophthalmic care: a systematic review</article-title><source>Adv Ophthalmol Pract Res</source><year>2024</year><volume>4</volume><issue>3</issue><fpage>120</fpage><lpage>127</lpage><pub-id pub-id-type="doi">10.1016/j.aopr.2024.03.003</pub-id><pub-id pub-id-type="medline">38846624</pub-id></nlm-citation></ref><ref id="ref37"><label>37</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Koyama</surname><given-names>A</given-names> </name><name name-style="western"><surname>Miyazaki</surname><given-names>D</given-names> </name><name name-style="western"><surname>Nakagawa</surname><given-names>Y</given-names> </name><etal/></person-group><article-title>Determination of probability of causative pathogen in infectious keratitis using deep learning algorithm of slit-lamp images</article-title><source>Sci Rep</source><year>2021</year><month>11</month><day>22</day><volume>11</volume><issue>1</issue><fpage>22642</fpage><pub-id pub-id-type="doi">10.1038/s41598-021-02138-w</pub-id><pub-id pub-id-type="medline">34811468</pub-id></nlm-citation></ref><ref id="ref38"><label>38</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Maehara</surname><given-names>H</given-names> </name><name name-style="western"><surname>Ueno</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Yamaguchi</surname><given-names>T</given-names> </name><etal/></person-group><article-title>Artificial intelligence support improves diagnosis accuracy in anterior segment eye diseases</article-title><source>Sci Rep</source><year>2025</year><month>02</month><day>11</day><volume>15</volume><issue>1</issue><fpage>5117</fpage><pub-id pub-id-type="doi">10.1038/s41598-025-89768-6</pub-id><pub-id pub-id-type="medline">39934383</pub-id></nlm-citation></ref><ref id="ref39"><label>39</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Alameddine</surname><given-names>M</given-names> </name><name name-style="western"><surname>Tamim</surname><given-names>H</given-names> </name><name name-style="western"><surname>Hadid</surname><given-names>D</given-names> </name><etal/></person-group><article-title>Patient attitudes toward mobile device use by health care providers in the emergency department: cross-sectional survey</article-title><source>JMIR mHealth uHealth</source><year>2020</year><month>03</month><day>31</day><volume>8</volume><issue>3</issue><fpage>e16917</fpage><pub-id pub-id-type="doi">10.2196/16917</pub-id><pub-id pub-id-type="medline">32229474</pub-id></nlm-citation></ref></ref-list><app-group><supplementary-material id="app1"><label>Multimedia Appendix 1</label><p>The survey, which was disseminated to participants, exploring their perceptions of the 4 devices tested.</p><media xlink:href="formative_v10i1e89441_app1.docx" xlink:title="DOCX File, 157 KB"/></supplementary-material><supplementary-material id="app2"><label>Multimedia Appendix 2</label><p>The interview guide used in all interviews to allow for consistency.</p><media xlink:href="formative_v10i1e89441_app2.docx" xlink:title="DOCX File, 17 KB"/></supplementary-material></app-group></back></article>