<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Form Res</journal-id><journal-id journal-id-type="publisher-id">formative</journal-id><journal-id journal-id-type="index">27</journal-id><journal-title>JMIR Formative Research</journal-title><abbrev-journal-title>JMIR Form Res</abbrev-journal-title><issn pub-type="epub">2561-326X</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v10i1e83090</article-id><article-id pub-id-type="doi">10.2196/83090</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Validity of Galaxy Watch for Estimating Energy Expenditure During Intermittent Running: Cross-Sectional Study</article-title></title-group><contrib-group><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Ferreira</surname><given-names>Alexandre Reis Pires</given-names></name><degrees>MSc</degrees><xref ref-type="aff" rid="aff1"/><xref ref-type="fn" rid="equal-contrib1">*</xref></contrib><contrib contrib-type="author" equal-contrib="yes"><name name-style="western"><surname>Inoue</surname><given-names>Allan</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1"/><xref ref-type="fn" rid="equal-contrib1">*</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Barbosa</surname><given-names>Ramon Ludman Martins</given-names></name><degrees>BCS</degrees><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Hayek</surname><given-names>Cassio</given-names></name><degrees>BCS</degrees><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Reis</surname><given-names>Mateus</given-names></name><degrees>BCS</degrees><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Alc&#x00E2;ntara</surname><given-names>Jo&#x00E3;o Arthur</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name name-style="western"><surname>Shigueoka</surname><given-names>Augusto Hirao</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>dos Santos</surname><given-names>Marcelo Rodrigues</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff id="aff1"><institution>Sidia Institute of Science and Technology</institution><addr-line>Av. Autaz Mirim, 2211 - Distrito Industrial I</addr-line><addr-line>Manaus</addr-line><country>Brazil</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Schwartz</surname><given-names>Amy</given-names></name></contrib><contrib contrib-type="editor"><name name-style="western"><surname>Balcarras</surname><given-names>Matthew</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Samuel</surname><given-names>Adebero</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Ruparel</surname><given-names>Ritesh</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Marcelo Rodrigues dos Santos, PhD, Sidia Institute of Science and Technology, Av. Autaz Mirim, 2211 - Distrito Industrial I, Manaus, 69075-155, Brazil, 55 92 3212-3444; <email>marcelo.rodrigues@sidia.com</email></corresp><fn fn-type="equal" id="equal-contrib1"><label>*</label><p>these authors contributed equally</p></fn></author-notes><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>18</day><month>3</month><year>2026</year></pub-date><volume>10</volume><elocation-id>e83090</elocation-id><history><date date-type="received"><day>28</day><month>08</month><year>2025</year></date><date date-type="accepted"><day>12</day><month>01</month><year>2026</year></date></history><copyright-statement>&#x00A9; Alexandre Reis Pires Ferreira, Allan Inoue, Ramon Ludman Martins Barbosa, Cassio Hayek, Mateus Reis, Jo&#x00E3;o Arthur Alc&#x00E2;ntara, Augusto Hirao Shigueoka, Marcelo Rodrigues dos Santos. Originally published in JMIR Formative Research (<ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>), 18.3.2026. </copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://formative.jmir.org/2026/1/e83090"/><abstract><sec><title>Background</title><p>Smartwatches have gained popularity for their potential to provide accurate measurements of various physiological parameters. However, the validity of energy expenditure (EE) across different smartwatch models remains a topic of ongoing investigation. Discrepancies between results obtained from different models and gold standard methods are particularly critical across varying exercise intensities and types, as validation studies have demonstrated overestimation when wearable activity monitors are compared with indirect calorimetry.</p></sec><sec><title>Objective</title><p>This study investigated the accuracy of 2 versions of the Samsung smartwatch (Galaxy Watch [GW] 6 and 7) in measuring EE during intermittent moderate-intensity running exercises, using indirect calorimetry as the gold standard method.</p></sec><sec sec-type="methods"><title>Methods</title><p>This study included 148 healthy adults, comprising 80 men and 68 women. Participants performed intermittent treadmill running, consisting of walking at 5 km&#x00B7;h&#x207B;&#x00B9; for 1 minute and running between 8 and 16 km&#x00B7;h&#x207B;&#x00B9; for 2 minutes, based on participant preference, for a total duration of 27 minutes. The GW6 and GW7 models were used and EE was measured by indirect calorimetry using a wearable portable metabolic gas analysis system (K5; Cosmed), which is considered a gold standard method.</p></sec><sec sec-type="results"><title>Results</title><p>No statistically significant differences were found between the GW models and the K5. The K5 showed a mean EE of 213.60 (SD 43.04) kilocalories, compared with 219.53 (SD 35.70) kilocalories for the GW6 and 202.67 (SD 47.42) kilocalories for the GW7 (all <italic>P</italic>&#x003E;.05). Good Spearman correlations (0.63&#x2010;0.70) and moderate intraclass correlation coefficients (0.65&#x2010;0.74) were found. Mean absolute percentage error values ranged from 10.10% to 12.55%. Bland-Altman analysis revealed limits of agreement for all comparisons (K5 vs GW6 and GW7, &#x2212;61.93 to 65.80 kcal).</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>The GW6 and GW7 devices showed moderate validity for estimating EE during intermittent running exercises, demonstrating the suitability of the GW as a low-cost and practical wearable option for daily physical activities.</p></sec></abstract><kwd-group><kwd>energy expenditure</kwd><kwd>calories</kwd><kwd>exercise</kwd><kwd>smartwatch</kwd><kwd>wearables</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>The accurate measurement of energy expenditure (EE) during physical activity is essential for both research and practical applications in sports science, fitness, and health monitoring. Wearable technology, such as smartwatches, has become increasingly popular due to its convenience, ease of use, and ability to provide real-time data. Among these devices, smartwatches have gained popularity for their potential to offer accurate measurements of various physiological parameters, including heart rate, step count, and EE [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref2">2</xref>]. However, the validity and reliability of EE across different smartwatch models remain a topic of ongoing investigation.</p><p>Recent advances in sensor technology and algorithm development have enabled smartwatches to estimate EE by combining data from accelerometers, heart rate monitors, and other sensors. Despite these advancements, questions persist regarding the accuracy of these devices compared with established gold standard methods, such as indirect calorimetry and doubly labeled water techniques [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref3">3</xref>,<xref ref-type="bibr" rid="ref4">4</xref>]. This discrepancy is particularly critical across varying exercise intensities and types, where the accuracy of EE estimation may fluctuate. Validation studies have demonstrated that wearable activity monitors tend to overestimate EE when compared with indirect calorimetry [<xref ref-type="bibr" rid="ref5">5</xref>-<xref ref-type="bibr" rid="ref7">7</xref>], highlighting the need for accurate EE estimation to ensure effective fitness monitoring and possible research applicability.</p><p>Interdevice reliability differences in EE estimation were observed between Fitbit (Google LLC) smartwatch models depending on the type of exercise performed, with intraclass correlation coefficients (ICCs) ranging from 0.48 for jogging to 0.97 for walking. These values were compared with indirect calorimetry, which had ICCs ranging from 0.58 to 0.89 [<xref ref-type="bibr" rid="ref6">6</xref>]. Le et al [<xref ref-type="bibr" rid="ref1">1</xref>] evaluated the validity of the Apple Watch Series 6, Garmin FENIX 6, and Huawei Watch GT 2e for estimating EE during outdoor walking and running among young, lean Chinese adults. For walking and running activities, compared with indirect calorimetry, the Huawei Watch GT 2e demonstrated lower mean absolute percentage error (MAPE) values for EE estimation (9.9% and 11.9%, respectively), whereas Apple (19.8% and 24.4%, respectively) and Garmin (32% and 21.8%, respectively) showed higher MAPE values. For ICCs, higher values were observed for the Apple Watch during walking and running (0.821 and 0.74, respectively), followed by Huawei (0.760 and 0.698, respectively) and Garmin (0.216 and 0.594, respectively).</p><p>The Polar Grit X Pro smartwatch was considered valid for EE estimation across military training exercises (ICC, 0.8) when compared with indirect calorimetry assessment [<xref ref-type="bibr" rid="ref3">3</xref>]. Similarly, Roos et al [<xref ref-type="bibr" rid="ref8">8</xref>] analyzed the validity of 3 different smartwatches compared with indirect calorimetry at 2 different running intensities. The results showed that the accuracy of the smartwatches was intensity-dependent when compared at 30%, 50%, 70%, 90%, and 110% of the velocity associated with peak oxygen consumption (VO<sub>2 peak</sub>), with MAPE values ranging from 10.9% to 49.3% and the greatest variation observed at 110% of VO<sub>2 peak</sub> between smartwatch estimates and criterion measurements.</p><p>Limitations in smartwatch validation research include the absence of regulatory standards [<xref ref-type="bibr" rid="ref4">4</xref>], small sample sizes [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref3">3</xref>], heterogeneity of methods [<xref ref-type="bibr" rid="ref3">3</xref>-<xref ref-type="bibr" rid="ref5">5</xref>], and &#x201C;black box&#x201D; variables, such as algorithms and sensor updates. As demonstrated in previous studies, the accuracy of EE estimation and the heterogeneity of results across devices underscore the need for comprehensive validation methodologies, appropriate statistical approaches [<xref ref-type="bibr" rid="ref3">3</xref>,<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref8">8</xref>], and larger sample sizes [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref3">3</xref>].</p><p>The validity and accuracy of EE metrics provided by smartwatches are critical, as they are frequently used as decision-making data for physical activity and control of caloric intake [<xref ref-type="bibr" rid="ref4">4</xref>,<xref ref-type="bibr" rid="ref5">5</xref>]. In addition, the literature lacks three critical elements of smartwatch EE validity: (1) validity of EE measures in intermittent running activities, (2) accuracy across different models of the same smartwatch, and (3) more representative and larger sample sizes. Moreover, the validity of smartwatches is company- and model-dependent, as different companies tend to use distinct algorithms by patent issues, and the software may be upgraded in subsequent versions. In this context, it is important to conduct validity studies among growing companies in the health technology segment, such as Samsung, which has released at least 7 generations of smartwatches aimed at the health market.</p><p>This study aimed to evaluate the accuracy of 2 models of Samsung Galaxy Watch (GW; GW6 and GW7) in measuring EE during exercise, using gold standard methods as a reference (indirect calorimetry), during intermittent moderate-intensity running exercises. By assessing the performance of these devices, this study aimed to provide insights into their utility for both scientific research and everyday use among individuals seeking to monitor their health and fitness levels.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Study Design</title><p>This was a cross-sectional, within&#x2010;subject study designed to compare estimated EE from 2 models of the Samsung GW (the GW6 and the GW7) with criterion measures of EE obtained using a wearable metabolic gas analyzer (K5; Cosmed) during intermittent running. Reporting followed the Guidelines for Reporting Reliability and Agreement Studies [<xref ref-type="bibr" rid="ref9">9</xref>]. Three K5 gas analyzers were used to perform the measurements. Before any treadmill activity began, all participants were screened by a physician and a treadmill stress test was performed with a 12-lead electrocardiogram. After screening on a separate day, participants attended the laboratory to perform the tests. Skin color was measured using a Mexameter MX18 spectrophotometer (Courage+Khazaka electronic GmbH) and categorized between 1 and 6 following the Fitzpatrick Classification scale [<xref ref-type="bibr" rid="ref10">10</xref>]. The exercise protocol consisted of intermittent walking and running.</p></sec><sec id="s2-2"><title>Participants</title><p>This study recruited 148 healthy adults, comprising 80 men and 68 women. The participants were physically active and engaged in at least 150 minutes of moderate-intensity activity and/or 75 minutes of vigorous activity per week. Inclusion criteria were (1) being physically active, defined as engaging in at least 150 minutes of light- to moderate-intensity exercise, and (2) being aged 18 to 59 years. Exclusion criteria were (1) musculoskeletal injuries of the lower limbs, (2) cardiovascular or lung diseases, and (3) use of medications that impact heart rate response, such as beta blockers.</p></sec><sec id="s2-3"><title>Ethical Considerations</title><p>All participants were informed about the study procedures and provided written informed consent. This study was conducted in accordance with the ethical principles contained in the Declaration of Helsinki and complied with national regulations governing research involving human participants (466/12 of the National Health Council). The experimental procedures followed established ethical standards and were approved by the Investiga - Institutos de Pesquisa ethics committee (CAE 62031722.4.0000.5599). The privacy and confidentiality of all research participants and their data and identities were maintained throughout the study. All personal identifiers were removed from the dataset, and data were anonymized to ensure compliance with ethical standards. Access to the data was restricted to the research team, and all data were stored securely in accordance with institutional guidelines. In accordance with the legal regulations of our country, participants in this study did not receive monetary compensation. However, they were provided with reimbursement for transportation and meal expenses as a token of appreciation for their time and contributions.</p></sec><sec id="s2-4"><title>Exercise Protocol</title><p>To test the validity of the GW6 and the GW7 under standardized laboratory conditions, participants performed an activity of intermittent walking and running for a total duration of 27 minutes, consisting of walking at 5 km&#x00B7;h&#x207B;&#x00B9; and running between 8 and 16 km&#x00B7;h&#x207B;&#x00B9;, based on the participant&#x2019;s preference, on a commercial treadmill (Star Trac, E-TRxe). The protocol consisted of a 2-minute walking warm-up, followed by 7 repetitions of 2 minutes of running and 1 minute of walking, and concluded with an additional 4 minutes of walking recovery (27 min total).</p></sec><sec id="s2-5"><title>Criterion Measure</title><p>The K5 portable metabolic cart was used as the criterion method for estimating EE. This device is considered a valid and reliable system for measuring metabolic variables [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref11">11</xref>]. Device set up, calibration, and data extraction were conducted via OMNIA Metabolic software (version 1.6.10) (Cosmed). For the calculation of EE, oxygen uptake (VO<sub>2</sub>) was measured continuously, breath by breath, throughout the entire 27-minute protocol. Two pieces of K5 equipment were used for the data collection. Before each session, all K5 equipment was calibrated according to the manufacturer&#x2019;s instructions.</p></sec><sec id="s2-6"><title>Wearable Activity Monitors</title><p>Two GW models (GW6 and GW7) were used and connected to a smartphone (A22; Samsung Electronics), and all EE data was exported using the Samsung Health app. In cases in which activity data required trimming, full health data were exported via the Samsung Health app, and the raw CSV file was imported into Microsoft Excel (version 2310) for further analysis and cleaning. Participants&#x2019; weight, height, date of birth, and wrist orientation were entered into each watch before the activity protocol. The watches were positioned on the left arm, just above the wrist (2 cm above the ulnar styloid process), as per manufacturer instructions. The GWs were set to record the activity protocol as a workout, with watches being started and stopped at the beginning and at the end of the activity. The GWs were set to the &#x201C;treadmill&#x201D; mode.</p></sec><sec id="s2-7"><title>Statistical Analysis</title><p>The sample size was estimated a posteriori using a custom Python script, with an &#x03B1; level of .05 and statistical power of 0.90, identifying a minimum sample size of 29 participants for the GW6, 18 participants for the GW7, and 21 participants for both GW models. The power calculated using the actual sample size was 1.0 for all comparisons. Additionally, the sample size was considered adequate based on the recommendations of Chevance et al [<xref ref-type="bibr" rid="ref12">12</xref>], who consider sample sizes of more than 50 participants to be reasonably large. Moreover, the sample size in this study was larger than that of previous comparable studies of wrist-worn health-tracking devices, in which participant numbers ranged from 11 to 60 [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref3">3</xref>,<xref ref-type="bibr" rid="ref8">8</xref>,<xref ref-type="bibr" rid="ref13">13</xref>,<xref ref-type="bibr" rid="ref14">14</xref>]. Data distribution was inspected, and outliers were identified using boxplot analysis and removed if they exceeded the standard error limits. The lower limit was defined as the first quartile minus 1.5 &#x00D7; the interquartile range (IQR), and the upper limit was defined as the third quartile plus 1.5 &#x00D7; the IQR. Data normality was verified by the Shapiro-Wilk test.</p><p>Two&#x2010;sided paired <italic>t</italic> tests were used to compare the K5 with the GW6, the K5 with the GW7, and the K5 with the GW6 and GW7. Significant differences (<italic>P</italic>&#x003C;.05) were interpreted using Cohen <italic>d</italic> effect sizes, with the threshold defined as trivial (&#x003C;0.20), small (0.20&#x2010;0.59), moderate (0.60&#x2010;1.19), large (1.20&#x2010;1.99), and very large (2.00&#x2010;4.00) [<xref ref-type="bibr" rid="ref15">15</xref>]. To evaluate systematic differences, correlation, precision, and agreement between the wearables and the criterion measure, MAPE (calculated as [actual &#x2013; predicted]/actual &#x00D7; 100), ICC (2-way random-effects model, absolute agreement, single measurement), Spearman correlation, and Bland-Altman analysis were performed.</p><p>The MAPE value was interpreted as poor (&#x2265;20%), moderate (10.1%-19.9%), good (3.1%-10.0%), and excellent (0%-3%) [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref16">16</xref>]. Spearman correlation coefficients were interpreted as negligible (0.00-0.09), weak (0.10-0.39), moderate (0.40-0.69), strong (0.7-0.89), and very strong (0.90-1.00) [<xref ref-type="bibr" rid="ref17">17</xref>]. Finally, ICC values were interpreted as poor (&#x003C;0.50), moderate (0.50-0.74), good (0.75-0.89), and excellent (&#x2265;0.90) [<xref ref-type="bibr" rid="ref18">18</xref>].</p><p>Statistical analyses were performed using JASP software (version 0.18.3; JASP Team) and a custom Microsoft Excel (version 2506) spreadsheet [<xref ref-type="bibr" rid="ref19">19</xref>]. Statistical significance was set at <italic>P</italic>&#x2264;.05 (2-tailed). Based on the current literature, results were considered valid when values were at least moderate for ICCs, Spearman correlation, and MAPE.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><p>Participants had a mean age of 29.98 (SD 9.01) years, a mean height of 1.65 (SD 0.09) meters, a mean body mass of 65.53 (SD 11.18) kilograms, and a mean skin pigmentation score of 3.60 (SD 1.11) according to the Fitzpatrick classification scale. Energy expenditure during intermittent running is shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Energy expenditure during intermittent running with the Galaxy Watch (GW), measured with the Cosmed K5 metabolic gas analyzer.</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Devices (N=148)</td><td align="left" valign="bottom">Energy expenditure (kcal), mean (SD)</td><td align="left" valign="bottom">95% CI</td></tr></thead><tbody><tr><td align="left" valign="top">K5_GW6 (n=79)</td><td align="left" valign="top">218.63 (39.70)</td><td align="left" valign="top">227.52-209.74</td></tr><tr><td align="left" valign="top">K5_GW7 (n=69)</td><td align="left" valign="top">207.84 (46.20)</td><td align="left" valign="top">218.94-196.74</td></tr><tr><td align="left" valign="top">K5_All (n=148)</td><td align="left" valign="top">213.60<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup> (43.04)</td><td align="left" valign="top">220.59-206.61</td></tr><tr><td align="left" valign="top">GW6 (n=79)</td><td align="left" valign="top">219.53 (35.70)</td><td align="left" valign="top">227.53-211.54</td></tr><tr><td align="left" valign="top">GW7 (n=69)</td><td align="left" valign="top">202.67<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup> (47.42)</td><td align="left" valign="top">214.06-191.28</td></tr><tr><td align="left" valign="top">GW_All (n=148)</td><td align="left" valign="top">211.67 (42.28)</td><td align="left" valign="top">218.54-204.80</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>Statistical significance for the Shapiro-Wilk test (<italic>P</italic>&#x2264;.05).</p></fn></table-wrap-foot></table-wrap><p><xref ref-type="table" rid="table2">Table 2</xref> shows systematic differences, correlations, and measure of precision. For systematic differences, a paired <italic>t</italic> test was conducted to compare EE values between the K5 and the GW6. No statistically significant differences were found between the K5 versus the GW6, the K5 and GW7, or the K5 and the combined GW6 and GW7 (GW6+GW7). Spearman correlation indicated moderate associations between the K5 and GW6 and between the K5 and the combined GW6 and GW7, and a strong association between the K5 and GW7. Moreover, moderate ICC and MAPE values were found for all comparisons.</p><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Spearman correlation (SC), intraclass correlation (ICC), and mean absolute percentage error (MAPE) of energy expenditure during intermittent running with the Galaxy Watch (GW) and Cosmed K5 metabolic gas analyzer.</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Devices (criterion, practical)</td><td align="left" valign="bottom">SC (95% CI)</td><td align="left" valign="bottom">ICC (95% CI)</td><td align="left" valign="bottom">MAPE, mean (SD)</td></tr></thead><tbody><tr><td align="left" valign="top">K5, GW6</td><td align="left" valign="top">0.63<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup> (0.47-0.75)</td><td align="left" valign="top">0.65 (0.55-0.74)</td><td align="left" valign="top">10.10 (9.34)</td></tr><tr><td align="left" valign="top">K5, GW7</td><td align="left" valign="top">0.70<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup> (0.55-0.80)</td><td align="left" valign="top">0.74 (0.66-0.81)</td><td align="left" valign="top">12.55 (8.78)</td></tr><tr><td align="left" valign="top">K5_GW6+GW7</td><td align="left" valign="top">0.67<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup> (0.57-0.75)</td><td align="left" valign="top">0.71 (0.62-0.78)</td><td align="left" valign="top">10.86 (9.06)</td></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>Statistical significance for the Spearman correlation at <italic>P</italic>&#x2264;.05.</p></fn></table-wrap-foot></table-wrap><p><xref ref-type="fig" rid="figure1">Figure 1</xref> shows Bland-Altman plots with bias and limits of agreement between criterion and practical measurements, presented as mean, upper, and lower calorie values.</p><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Bland-Altman LOA between the (A) Cosmed K5 metabolic gas analyzer and GW6, (B) Cosmed K5 metabolic gas analyzer and GW7, and (C) Cosmed K5 metabolic gas analyzer and GW6 and GW7. GW: Galaxy Watch; LOA: limits of agreement.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v10i1e83090_fig01.png"/></fig></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Principal Findings</title><p>The Samsung GW6 and GW7 models were evaluated for validity in estimating EE during intermittent, moderate-intensity exercise. The results showed a moderate to strong correlation and no statistically significant difference in paired <italic>t</italic> tests when compared with the gold standard of indirect calorimetry. Additionally, both the GW6 and GW7 models achieved a MAPE value of less than 15%, which indicates a moderate absolute error.</p><p>Existing literature reveals variability in smartwatch validation results due to differing algorithms, hardware generations, and study designs. For instance, LaMunion et al [<xref ref-type="bibr" rid="ref20">20</xref>] found significant differences between 5 consumer devices, including 4 smartwatches, when compared with the Cosmed K4b<sup>2</sup> portable metabolic gas analysis system during semistructured daily activities. In contrast, the GW6 and GW7 models in our study showed moderate validity under intermittent running conditions compared with the K5 gas analyzer, likely due to advancements in technology and the structured exercise protocol used in this study.</p><p>Previous studies have reported EE estimation with mean ICC values ranging from &#x2212;0.30 to 0.97 [<xref ref-type="bibr" rid="ref3">3</xref>,<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref6">6</xref>,<xref ref-type="bibr" rid="ref21">21</xref>], 95% CIs ranging from &#x2212;0.89 to 0.98 [<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref6">6</xref>,<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref22">22</xref>], and MAPE values ranging from 1.3% to 114.7% [<xref ref-type="bibr" rid="ref21">21</xref>-<xref ref-type="bibr" rid="ref23">23</xref>]. Among the studies, Wahl et al [<xref ref-type="bibr" rid="ref21">21</xref>] analyzed 11 different wearable watches in walking and running protocols at speeds of 4.3, 7.2, 10.1, and 13.0 km&#x00B7;h<sup>-1</sup>. Mean ICC values greater than 0.70 were observed for only 4 smartwatches, whereas ICC values greater than 0.50 were observed for 6 smartwatches. Mean absolute percentage error values ranged from 1.3% to 56.0%. For ICCs, 17 of 66 measurements were greater than 0.5, and only 3 of these were obtained under intermittent conditions (mean ICC range 0.54-0.74). For MAPE, 24 of 66 measurements were less than 10%, and only 5 of these were obtained under intermittent conditions, ranging from &#x2212;9.2% to 5.6%.</p><p>The moderate ICC and MAPE values for the GW6 and the GW7 compared with the K5 were considered acceptable indicators of validity, as previously reported [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref12">12</xref>,<xref ref-type="bibr" rid="ref13">13</xref>]. Associations between variables were also assessed using Spearman correlation, demonstrating moderate values for the GW6 group and the combined GW6 and GW7 group, and strong values for the GW7 group. Moreover, the database comprised both men and women, resulting in a heterogeneous sample. As expected, heterogeneous samples may influence accuracy metrics, as smartwatch EE estimates have been shown to differ across different demographic groups [<xref ref-type="bibr" rid="ref24">24</xref>].</p><p>It is important to highlight that different types of exercises can affect the variability of smartwatch accuracy [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref21">21</xref>]. The assessment of EE in this study differs from previous investigations primarily in terms of device performance and testing conditions. Earlier research has demonstrated generally low validity for consumer wearable activity monitors in estimating EE (particularly under both constant and intermittent running protocols) [<xref ref-type="bibr" rid="ref21">21</xref>]. Wahl et al [<xref ref-type="bibr" rid="ref21">21</xref>] highlighted consistent overestimation of EE at lower speeds and underestimation at higher speeds. While not perfectly valid, the Garmin, Fitbit, and Withings (Withings SA) wearable watches generally showed better validity with small to moderate MAPE values (1.3%&#x2010;21.2%), particularly at faster velocities (10.1 km&#x00B7;h<sup>&#x2212;1</sup> and 13.0 km&#x00B7;h<sup>&#x2212;1</sup>) and in outdoor conditions. Devices such as the Garmin Vivofit, Garmin Vivosmart, Garmin Vivoactive, Fitbit Charge, and Fitbit Charge HR exhibited moderate to good ICCs, suggesting a relatively better correlation with the criterion measure compared with other brands. However, even for these devices, the limits of agreement were still insufficiently narrow, indicating considerable variability and imprecision.</p><p>For the intermittent protocol, which simulates conditions in sports such as soccer, the Fitbit Charge, Garmin Vivoactive, Garmin Vivosmart, and Polar Loop showed a relatively small MAPE (&#x003C;5.6%). However, most other devices, including the Withings Pulse Ox (wrist or hip), Garmin Forerunner 920XT, Garmin Vivofit, Beurer AS80, and Bodymedia Sensewear, primarily underestimated EE during this dynamic activity. This reinforces the concern that most commercially available wearable activity monitors lack the accuracy required to reliably estimate EE in real-world exercise scenarios, especially among athletes.</p><p>The magnitude of the limits of agreement for these wearable activity monitors indicates that, although average error during intermittent running can be small to moderate in relative terms, individual-level EE estimates can still deviate by several hundred kilocalories in a typical session, which is likely too large for precise real-world monitoring, especially in athletes [<xref ref-type="bibr" rid="ref21">21</xref>]. During intermittent exercise, rapid changes in speed, direction, and intensity violate the steady state assumptions many EE algorithms rely on, leading to larger MAPE values and wider limits of agreement than during constant-velocity running [<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref25">25</xref>].</p><p>When compared with criterion measures, several studies have demonstrated that wearable activity monitors underestimate EE in both laboratory and outdoor tests [<xref ref-type="bibr" rid="ref2">2</xref>,<xref ref-type="bibr" rid="ref8">8</xref>,<xref ref-type="bibr" rid="ref13">13</xref>,<xref ref-type="bibr" rid="ref23">23</xref>,<xref ref-type="bibr" rid="ref26">26</xref>], demonstrating a mean value of approximately 3 kilocalories and percentage errors ranging from &#x2212;21.27% to 14.76% [<xref ref-type="bibr" rid="ref23">23</xref>]. Importantly, few studies have analyzed the EE validity of Samsung smartwatches, with the Samsung Gear models being the most tested smartwatches [<xref ref-type="bibr" rid="ref26">26</xref>]. Likewise, Sun et al [<xref ref-type="bibr" rid="ref13">13</xref>] identified EE overestimation in the Apple Watch Series 6 when compared with a breath-by-breath gas analyzer (MetaMax 3B; CORTEX Biophysik GmbH) across different running velocities (6.4-11.2 km&#x00B7;h&#x207B;&#x00B9;), despite high MAPE values (&#x2013;6.61 to 53.24).</p><p>One limitation of this study is that only 1 brand of smartwatch was tested. While this could be seen as a constraint, it also presents an advantage by allowing for a direct comparison of technological improvements for a specific model within the same brand. By examining the evolution of technology in this specific area, we gain valuable insights into how advancements have positively impacted the accuracy of these devices over time. Another limitation is that the study tested EE measurement during 1 type of exercise and only in healthy, lean people. This restricts the scope of our findings, as the accuracy of smartwatch EE estimates can vary across different forms of physical activity and physical characteristics. Future research should address this limitation by evaluating the performance of these devices across a wider range of populations and exercise modalities, such as resistance training, high-intensity interval training, and low-intensity steady-state exercise. This would provide a more comprehensive understanding of the accuracy of devices and limitations in various exercise contexts. Another limitation of this study is that 2 different K5 devices were used in data collection. Although manufacturer calibration was performed immediately after the data collection sessions, no between-device validation was conducted. Future research should use a single device throughout the data collection period or perform between-device validation.</p></sec><sec id="s4-2"><title>Practical Implications</title><p>The following points summarize the practical implications of the present findings.</p><list list-type="bullet"><list-item><p>Both the GW6 and the GW7 can be used for EE estimation in intermittent running exercises, providing valid data for athletes and fitness enthusiasts.</p></list-item><list-item><p>Advancements in the GW7 highlight the importance of algorithm and hardware updates and underscore the need for continuous development in the wearable activity monitor industry.</p></list-item><list-item><p>This study helps consumers make more informed decisions regarding which smartwatch model is best suited for accurate fitness tracking.</p></list-item><list-item><p>The results of this study set a benchmark for future validation studies, promoting a more standardized approach in wearable technology research.</p></list-item></list></sec><sec id="s4-3"><title>Conclusions</title><p>Both the GW6 and GW7 models showed moderate validity for estimating EE during intermittent running exercises. These findings support the growing reliability of newer smartwatches for EE estimation in structured exercise settings. Given their relatively low cost and practicality, GWs emerge as a suitable wearable option for daily physical activity where EE is of interest.</p></sec></sec></body><back><ack><p>The authors thank all participants who volunteered to take part in the study and the staff who assisted in data collection. This article is the result of the R&#x0026;D project Health Data Lab, conducted by the Sidia Institute of Science and Technology in partnership with Samsung Electronics of the Amazon Ltda, using resources provided under Federal Law No. 8,387/1991. Its disclosure and publicity comply with the provisions of Article 39 of Decree No. 10,521/2020. No generative artificial intelligence tools were used in this study.</p></ack><notes><sec><title>Funding</title><p>This study was funded by Samsung Eletr&#x00F4;nica da Amaz&#x00F4;nia Ltda.</p></sec></notes><fn-group><fn fn-type="conflict"><p>All authors are employees of the Sidia Institute of Science and Technology. The company was not involved in data or sample collection, analysis, or interpretation of the results. No restrictions were placed on the reporting of findings.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">EE</term><def><p>energy expenditure</p></def></def-item><def-item><term id="abb2">GW</term><def><p>Galaxy Watch</p></def></def-item><def-item><term id="abb3">ICC</term><def><p>intraclass correlation coefficient</p></def></def-item><def-item><term id="abb4">MAPE</term><def><p>mean absolute percentage error</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Le</surname><given-names>S</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>X</given-names> </name><name name-style="western"><surname>Zhang</surname><given-names>T</given-names> </name><etal/></person-group><article-title>Validity of three smartwatches in estimating energy expenditure during outdoor walking and running</article-title><source>Front Physiol</source><year>2022</year><volume>13</volume><fpage>995575</fpage><pub-id pub-id-type="doi">10.3389/fphys.2022.995575</pub-id><pub-id pub-id-type="medline">36225296</pub-id></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bunn</surname><given-names>JA</given-names> </name><name name-style="western"><surname>Navalta</surname><given-names>JW</given-names> </name><name name-style="western"><surname>Fountaine</surname><given-names>CJ</given-names> </name><name name-style="western"><surname>Reece</surname><given-names>JD</given-names> </name></person-group><article-title>Current state of commercial wearable technology in physical activity monitoring 2015-2017</article-title><source>Int J Exerc Sci</source><year>2018</year><volume>11</volume><issue>7</issue><fpage>503</fpage><lpage>515</lpage><pub-id pub-id-type="doi">10.70252/NJQX2719</pub-id><pub-id pub-id-type="medline">29541338</pub-id></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kloss</surname><given-names>EB</given-names> </name><name name-style="western"><surname>Givens</surname><given-names>A</given-names> </name><name name-style="western"><surname>Palombo</surname><given-names>L</given-names> </name><etal/></person-group><article-title>Validation of Polar Grit X Pro for estimating energy expenditure during military field training: a pilot study</article-title><source>J Sports Sci Med</source><year>2023</year><month>12</month><volume>22</volume><issue>4</issue><fpage>658</fpage><lpage>666</lpage><pub-id pub-id-type="doi">10.52082/jssm.2023.658</pub-id><pub-id pub-id-type="medline">38045749</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Argent</surname><given-names>R</given-names> </name><name name-style="western"><surname>Hetherington-Rauth</surname><given-names>M</given-names> </name><name name-style="western"><surname>Stang</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Recommendations for determining the validity of consumer wearables and smartphones for the estimation of energy expenditure: expert statement and checklist of the INTERLIVE network</article-title><source>Sports Med</source><year>2022</year><month>08</month><volume>52</volume><issue>8</issue><fpage>1817</fpage><lpage>1832</lpage><pub-id pub-id-type="doi">10.1007/s40279-022-01665-4</pub-id><pub-id pub-id-type="medline">35260991</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Evenson</surname><given-names>KR</given-names> </name><name name-style="western"><surname>Goto</surname><given-names>MM</given-names> </name><name name-style="western"><surname>Furberg</surname><given-names>RD</given-names> </name></person-group><article-title>Systematic review of the validity and reliability of consumer-wearable activity trackers</article-title><source>Int J Behav Nutr Phys Act</source><year>2015</year><month>12</month><day>18</day><volume>12</volume><fpage>159</fpage><pub-id pub-id-type="doi">10.1186/s12966-015-0314-1</pub-id><pub-id pub-id-type="medline">26684758</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Adam Noah</surname><given-names>J</given-names> </name><name name-style="western"><surname>Spierer</surname><given-names>DK</given-names> </name><name name-style="western"><surname>Gu</surname><given-names>J</given-names> </name><name name-style="western"><surname>Bronner</surname><given-names>S</given-names> </name></person-group><article-title>Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry</article-title><source>J Med Eng Technol</source><year>2013</year><month>10</month><volume>37</volume><issue>7</issue><fpage>456</fpage><lpage>462</lpage><pub-id pub-id-type="doi">10.3109/03091902.2013.831135</pub-id><pub-id pub-id-type="medline">24007317</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bai</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Welk</surname><given-names>GJ</given-names> </name><name name-style="western"><surname>Nam</surname><given-names>YH</given-names> </name><etal/></person-group><article-title>Comparison of consumer and research monitors under semistructured settings</article-title><source>Med Sci Sports Exerc</source><year>2016</year><month>01</month><volume>48</volume><issue>1</issue><fpage>151</fpage><lpage>158</lpage><pub-id pub-id-type="doi">10.1249/MSS.0000000000000727</pub-id><pub-id pub-id-type="medline">26154336</pub-id></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Roos</surname><given-names>L</given-names> </name><name name-style="western"><surname>Taube</surname><given-names>W</given-names> </name><name name-style="western"><surname>Beeler</surname><given-names>N</given-names> </name><name name-style="western"><surname>Wyss</surname><given-names>T</given-names> </name></person-group><article-title>Validity of sports watches when estimating energy expenditure during running</article-title><source>BMC Sports Sci Med Rehabil</source><year>2017</year><volume>9</volume><fpage>22</fpage><pub-id pub-id-type="doi">10.1186/s13102-017-0089-6</pub-id><pub-id pub-id-type="medline">29296281</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kottner</surname><given-names>J</given-names> </name><name name-style="western"><surname>Audig&#x00E9;</surname><given-names>L</given-names> </name><name name-style="western"><surname>Brorson</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Guidelines for reporting reliability and agreement studies (GRRAS) were proposed</article-title><source>J Clin Epidemiol</source><year>2011</year><month>01</month><volume>64</volume><issue>1</issue><fpage>96</fpage><lpage>106</lpage><pub-id pub-id-type="doi">10.1016/j.jclinepi.2010.03.002</pub-id><pub-id pub-id-type="medline">21130355</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fitzpatrick</surname><given-names>TB</given-names> </name></person-group><article-title>The validity and practicality of sun-reactive skin types I through VI</article-title><source>Arch Dermatol</source><year>1988</year><month>06</month><day>1</day><volume>124</volume><issue>6</issue><fpage>869</fpage><pub-id pub-id-type="doi">10.1001/archderm.1988.01670060015008</pub-id></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>DeBlois</surname><given-names>JP</given-names> </name><name name-style="western"><surname>White</surname><given-names>LE</given-names> </name><name name-style="western"><surname>Barreira</surname><given-names>TV</given-names> </name></person-group><article-title>Reliability and validity of the COSMED K5 portable metabolic system during walking</article-title><source>Eur J Appl Physiol</source><year>2021</year><month>01</month><volume>121</volume><issue>1</issue><fpage>209</fpage><lpage>217</lpage><pub-id pub-id-type="doi">10.1007/s00421-020-04514-2</pub-id><pub-id pub-id-type="medline">33011874</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chevance</surname><given-names>G</given-names> </name><name name-style="western"><surname>Golaszewski</surname><given-names>NM</given-names> </name><name name-style="western"><surname>Tipton</surname><given-names>E</given-names> </name><etal/></person-group><article-title>Accuracy and precision of energy expenditure, heart rate, and steps measured by combined-sensing Fitbits against reference measures: systematic review and meta-analysis</article-title><source>JMIR mHealth uHealth</source><year>2022</year><month>04</month><day>13</day><volume>10</volume><issue>4</issue><fpage>e35626</fpage><pub-id pub-id-type="doi">10.2196/35626</pub-id><pub-id pub-id-type="medline">35416777</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sun</surname><given-names>X</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>Z</given-names> </name><name name-style="western"><surname>Fu</surname><given-names>X</given-names> </name><name name-style="western"><surname>Zhao</surname><given-names>C</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>F</given-names> </name><name name-style="western"><surname>He</surname><given-names>H</given-names> </name></person-group><article-title>Validity of Apple Watch 6 and Polar A370 for monitoring energy expenditure while resting or performing light to vigorous physical activity</article-title><source>J Sci Med Sport</source><year>2023</year><month>09</month><volume>26</volume><issue>9</issue><fpage>482</fpage><lpage>486</lpage><pub-id pub-id-type="doi">10.1016/j.jsams.2023.07.005</pub-id><pub-id pub-id-type="medline">37517888</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Nelson</surname><given-names>MB</given-names> </name><name name-style="western"><surname>Kaminsky</surname><given-names>LA</given-names> </name><name name-style="western"><surname>Dickin</surname><given-names>DC</given-names> </name><name name-style="western"><surname>Montoye</surname><given-names>AHK</given-names> </name></person-group><article-title>Validity of consumer-based physical activity monitors for specific activity types</article-title><source>Med Sci Sports Exerc</source><year>2016</year><month>08</month><volume>48</volume><issue>8</issue><fpage>1619</fpage><lpage>1628</lpage><pub-id pub-id-type="doi">10.1249/MSS.0000000000000933</pub-id><pub-id pub-id-type="medline">27015387</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hopkins</surname><given-names>WG</given-names> </name><name name-style="western"><surname>Marshall</surname><given-names>SW</given-names> </name><name name-style="western"><surname>Batterham</surname><given-names>AM</given-names> </name><name name-style="western"><surname>Hanin</surname><given-names>J</given-names> </name></person-group><article-title>Progressive statistics for studies in sports medicine and exercise science</article-title><source>Med Sci Sports Exerc</source><year>2009</year><month>01</month><volume>41</volume><issue>1</issue><fpage>3</fpage><lpage>13</lpage><pub-id pub-id-type="doi">10.1249/MSS.0b013e31818cb278</pub-id><pub-id pub-id-type="medline">19092709</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Danielsson</surname><given-names>ML</given-names> </name><name name-style="western"><surname>Vergeer</surname><given-names>M</given-names> </name><name name-style="western"><surname>Plasqui</surname><given-names>G</given-names> </name><name name-style="western"><surname>Baumgart</surname><given-names>JK</given-names> </name></person-group><article-title>Accuracy of the Apple Watch Series 4 and Fitbit Versa for assessing energy expenditure and heart rate of wheelchair users during treadmill wheelchair propulsion: cross-sectional study</article-title><source>JMIR Form Res</source><year>2024</year><month>05</month><day>7</day><volume>8</volume><fpage>e52312</fpage><pub-id pub-id-type="doi">10.2196/52312</pub-id><pub-id pub-id-type="medline">38713497</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Schober</surname><given-names>P</given-names> </name><name name-style="western"><surname>Boer</surname><given-names>C</given-names> </name><name name-style="western"><surname>Schwarte</surname><given-names>LA</given-names> </name></person-group><article-title>Correlation coefficients: appropriate use and interpretation</article-title><source>Anesth Analg</source><year>2018</year><month>05</month><volume>126</volume><issue>5</issue><fpage>1763</fpage><lpage>1768</lpage><pub-id pub-id-type="doi">10.1213/ANE.0000000000002864</pub-id><pub-id pub-id-type="medline">29481436</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Koo</surname><given-names>TK</given-names> </name><name name-style="western"><surname>Li</surname><given-names>MY</given-names> </name></person-group><article-title>A guideline of selecting and reporting intraclass correlation coefficients for reliability research</article-title><source>J Chiropr Med</source><year>2016</year><month>06</month><volume>15</volume><issue>2</issue><fpage>155</fpage><lpage>163</lpage><pub-id pub-id-type="doi">10.1016/j.jcm.2016.02.012</pub-id><pub-id pub-id-type="medline">27330520</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hopkins</surname><given-names>WG</given-names> </name></person-group><article-title>Spreadsheets for analysis of validity and reliability</article-title><source>Sportscience</source><year>2015</year><access-date>2026-02-24</access-date><volume>19</volume><fpage>36</fpage><lpage>45</lpage><comment><ext-link ext-link-type="uri" xlink:href="https://sportsci.org/2015/ValidRely.htm">https://sportsci.org/2015/ValidRely.htm</ext-link></comment></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>LaMunion</surname><given-names>SR</given-names> </name><name name-style="western"><surname>Blythe</surname><given-names>AL</given-names> </name><name name-style="western"><surname>Hibbing</surname><given-names>PR</given-names> </name><name name-style="western"><surname>Kaplan</surname><given-names>AS</given-names> </name><name name-style="western"><surname>Clendenin</surname><given-names>BJ</given-names> </name><name name-style="western"><surname>Crouter</surname><given-names>SE</given-names> </name></person-group><article-title>Use of consumer monitors for estimating energy expenditure in youth</article-title><source>Appl Physiol Nutr Metab</source><year>2020</year><month>02</month><volume>45</volume><issue>2</issue><fpage>161</fpage><lpage>168</lpage><pub-id pub-id-type="doi">10.1139/apnm-2019-0129</pub-id><pub-id pub-id-type="medline">31269409</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Wahl</surname><given-names>Y</given-names> </name><name name-style="western"><surname>D&#x00FC;king</surname><given-names>P</given-names> </name><name name-style="western"><surname>Droszez</surname><given-names>A</given-names> </name><name name-style="western"><surname>Wahl</surname><given-names>P</given-names> </name><name name-style="western"><surname>Mester</surname><given-names>J</given-names> </name></person-group><article-title>Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions</article-title><source>Front Physiol</source><year>2017</year><volume>8</volume><fpage>725</fpage><pub-id pub-id-type="doi">10.3389/fphys.2017.00725</pub-id><pub-id pub-id-type="medline">29018355</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Falter</surname><given-names>M</given-names> </name><name name-style="western"><surname>Budts</surname><given-names>W</given-names> </name><name name-style="western"><surname>Goetschalckx</surname><given-names>K</given-names> </name><name name-style="western"><surname>Cornelissen</surname><given-names>V</given-names> </name><name name-style="western"><surname>Buys</surname><given-names>R</given-names> </name></person-group><article-title>Accuracy of Apple Watch measurements for heart rate and energy expenditure in patients with cardiovascular disease: cross-sectional study</article-title><source>JMIR mHealth uHealth</source><year>2019</year><month>03</month><day>19</day><volume>7</volume><issue>3</issue><fpage>e11889</fpage><pub-id pub-id-type="doi">10.2196/11889</pub-id><pub-id pub-id-type="medline">30888332</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Doherty</surname><given-names>C</given-names> </name><name name-style="western"><surname>Baldwin</surname><given-names>M</given-names> </name><name name-style="western"><surname>Keogh</surname><given-names>A</given-names> </name><name name-style="western"><surname>Caulfield</surname><given-names>B</given-names> </name><name name-style="western"><surname>Argent</surname><given-names>R</given-names> </name></person-group><article-title>Keeping pace with wearables: a living umbrella review of systematic reviews evaluating the accuracy of consumer wearable technologies in health measurement</article-title><source>Sports Med</source><year>2024</year><month>11</month><volume>54</volume><issue>11</issue><fpage>2907</fpage><lpage>2926</lpage><pub-id pub-id-type="doi">10.1007/s40279-024-02077-2</pub-id><pub-id pub-id-type="medline">39080098</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Brazeau</surname><given-names>AS</given-names> </name><name name-style="western"><surname>Suppere</surname><given-names>C</given-names> </name><name name-style="western"><surname>Strychar</surname><given-names>I</given-names> </name><name name-style="western"><surname>Belisle</surname><given-names>V</given-names> </name><name name-style="western"><surname>Demers</surname><given-names>SP</given-names> </name><name name-style="western"><surname>Rabasa-Lhoret</surname><given-names>R</given-names> </name></person-group><article-title>Accuracy of energy expenditure estimation by activity monitors differs with ethnicity</article-title><source>Int J Sports Med</source><year>2014</year><month>09</month><volume>35</volume><issue>10</issue><fpage>847</fpage><lpage>850</lpage><pub-id pub-id-type="doi">10.1055/s-0034-1371837</pub-id><pub-id pub-id-type="medline">24816887</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>D&#x00FC;king</surname><given-names>P</given-names> </name><name name-style="western"><surname>Giessing</surname><given-names>L</given-names> </name><name name-style="western"><surname>Frenkel</surname><given-names>MO</given-names> </name><name name-style="western"><surname>Koehler</surname><given-names>K</given-names> </name><name name-style="western"><surname>Holmberg</surname><given-names>HC</given-names> </name><name name-style="western"><surname>Sperlich</surname><given-names>B</given-names> </name></person-group><article-title>Wrist-worn wearables for monitoring heart rate and energy expenditure while sitting or performing light-to-vigorous physical activity: validation study</article-title><source>JMIR mHealth uHealth</source><year>2020</year><month>05</month><day>6</day><volume>8</volume><issue>5</issue><fpage>e16716</fpage><pub-id pub-id-type="doi">10.2196/16716</pub-id><pub-id pub-id-type="medline">32374274</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fuller</surname><given-names>D</given-names> </name><name name-style="western"><surname>Colwell</surname><given-names>E</given-names> </name><name name-style="western"><surname>Low</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review</article-title><source>JMIR mHealth uHealth</source><year>2020</year><month>09</month><day>8</day><volume>8</volume><issue>9</issue><fpage>e18694</fpage><pub-id pub-id-type="doi">10.2196/18694</pub-id><pub-id pub-id-type="medline">32897239</pub-id></nlm-citation></ref></ref-list></back></article>