<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Form Res</journal-id><journal-id journal-id-type="publisher-id">formative</journal-id><journal-id journal-id-type="index">27</journal-id><journal-title>JMIR Formative Research</journal-title><abbrev-journal-title>JMIR Form Res</abbrev-journal-title><issn pub-type="epub">2561-326X</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v8i1e59521</article-id><article-id pub-id-type="doi">10.2196/59521</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Accuracy of the Huawei GT2 Smartwatch for Measuring Physical Activity and Sleep Among Adults During Daily Life: Instrument Validation Study</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Mei</surname><given-names>Longfei</given-names></name><degrees>MEd</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>He</surname><given-names>Ziwei</given-names></name><degrees>MEd</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Hu</surname><given-names>Liang</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff1">1</xref><xref ref-type="aff" rid="aff2">2</xref></contrib></contrib-group><aff id="aff1"><institution>Department of Sports Science, College of Education, Zhejiang University</institution><addr-line>No. 866, Yuhangtang Road</addr-line><addr-line>Hangzhou</addr-line><country>China</country></aff><aff id="aff2"><institution>Digital Sports and Health Laboratory, College of Education, Zhejiang University</institution><addr-line>Hangzhou</addr-line><country>China</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Mavragani</surname><given-names>Amaryllis</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Crabtree</surname><given-names>Daniel R</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Alomairah</surname><given-names>Saud</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Liang Hu, PhD, Department of Sports Science, College of Education, Zhejiang University, No. 866, Yuhangtang Road, Hangzhou, 310030, China, 86 18667127699; <email>lianghu@zju.edu.cn</email></corresp></author-notes><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>20</day><month>12</month><year>2024</year></pub-date><volume>8</volume><elocation-id>e59521</elocation-id><history><date date-type="received"><day>08</day><month>05</month><year>2024</year></date><date date-type="rev-recd"><day>08</day><month>10</month><year>2024</year></date><date date-type="accepted"><day>30</day><month>10</month><year>2024</year></date></history><copyright-statement>&#x00A9; Longfei Mei, Ziwei He, Liang Hu. Originally published in JMIR Formative Research (<ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>), 20.12.2024. </copyright-statement><copyright-year>2024</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://formative.jmir.org">https://formative.jmir.org</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://formative.jmir.org/2024/1/e59521"/><abstract><sec><title>Background</title><p>Smartwatches are increasingly popular for physical activity and health promotion. However, ongoing validation studies on commercial smartwatches are still needed to ensure their accuracy in assessing daily activity levels, which is important for both promoting activity-related health behaviors and serving research purposes.</p></sec><sec><title>Objective</title><p>This study aimed to evaluate the accuracy of a popular smartwatch, the Huawei Watch GT2, in measuring step count (SC), total daily activity energy expenditure (TDAEE), and total sleep time (TST) during daily activities among Chinese adults, and test whether there are population differences.</p></sec><sec sec-type="methods"><title>Methods</title><p>A total of 102 individuals were recruited and divided into 2 age groups: young adults (YAs) and middle-aged and older (MAAO) adults. Participants&#x2019; daily activity data were collected for 1 week by wearing the Huawei Watch GT2 on their nondominant wrist and the Actigraph GT3X+ (ActiGraph) on their right hip as the reference measure. The accuracy of the GT2 was examined using the intraclass correlation coefficient (ICC), Pearson product-moment correlation coefficient (PPMCC), Bland-Altman analysis, mean percentage error, and mean absolute percentage error (MAPE).</p></sec><sec sec-type="results"><title>Results</title><p>The GT2 demonstrated reasonable agreement with the Actigraph, as evidenced by a consistency test ICC of 0.88 (<italic>P</italic>&#x003C;.001) and an MAPE of 25.77% for step measurement, an ICC of 0.75 (<italic>P</italic>&#x003C;.001) and an MAPE of 33.79% for activity energy expenditure estimation, and an ICC of 0.25 (<italic>P</italic>&#x003C;.001) and an MAPE of 23.29% for sleep time assessment. Bland-Altman analysis revealed that the GT2 overestimated SC and underestimated TDAEE and TST. The GT2 was better at measuring SC and TDAEE among YAs than among MAAO adults, and there was no significant difference between these 2 groups in measuring TST (<italic>P</italic>=.12).</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>The Huawei Watch GT2 demonstrates good accuracy in step counting. However, its accuracy in assessing activity energy expenditure and sleep time measurement needs further examination. The GT2 demonstrated higher accuracy in measuring SC and TDAEE in the YA group than in the MAAO group. However, the measurement errors for TST did not differ significantly between the 2 age groups. Therefore, the watch may be suitable for monitoring several key parameters (eg, SC) of daily activity, yet caution is advised for its use in research studies that require high accuracy.</p></sec></abstract><kwd-group><kwd>smartwatch</kwd><kwd>accelerometry</kwd><kwd>free-living</kwd><kwd>physical activity</kwd><kwd>sleep</kwd><kwd>validity</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>Physical inactivity is recognized as a significant risk factor for many chronic noncommunicable diseases, including cardiovascular disease, certain malignancies (eg, colorectal cancer), and type 2 diabetes [<xref ref-type="bibr" rid="ref1">1</xref>], leading to increased mortality, reduced quality of life, shorter life expectancy [<xref ref-type="bibr" rid="ref2">2</xref>-<xref ref-type="bibr" rid="ref4">4</xref>], and a significant financial burden on the health care system [<xref ref-type="bibr" rid="ref5">5</xref>]. Hence, interventions aimed at increasing physical activity are critical to public health. In this regard, sustained efforts of regular and accurate monitoring of physical activity are necessary [<xref ref-type="bibr" rid="ref6">6</xref>-<xref ref-type="bibr" rid="ref8">8</xref>]. To achieve this goal, researchers and health practitioners have been continuously in search of physical activity measurement methods that best balance precision and cost. High-precision monitoring methods such as double-labeled water and indirect calorimetry are not suitable for daily life due to high cost and user burden [<xref ref-type="bibr" rid="ref9">9</xref>]. Pedometers and accelerometers are relatively easy to carry in daily life but offer only limited indices that mostly focus on activity counts, rather than physiological measures (eg, heart rate), and the latter is also expensive [<xref ref-type="bibr" rid="ref8">8</xref>,<xref ref-type="bibr" rid="ref9">9</xref>]. Questionnaires are commonly used, particularly in large-sample surveys, but have often been questioned for being highly subjective [<xref ref-type="bibr" rid="ref8">8</xref>-<xref ref-type="bibr" rid="ref10">10</xref>].</p><p>With rapid technological advancements, smartwatches have become increasingly popular for monitoring and promoting health behaviors such as physical activity, sedentary behavior, and sleep. Such devices are valued for their multifunctionality, convenience, comfort, and cost-effectiveness. Specifically, smartwatches have multiple built-in sensor devices, such as accelerometers and optical heart rate sensors, which may achieve a higher level of measurement accuracy and cover a variety of indices (eg, duration of certain behavior, heart rate, and oxygen saturation) than pedometers and accelerometers that are commonly used in research settings [<xref ref-type="bibr" rid="ref11">11</xref>].</p><p>Recent studies highlight the role of smartwatches in enhancing exercise motivation and facilitating healthier lifestyle choices [<xref ref-type="bibr" rid="ref12">12</xref>-<xref ref-type="bibr" rid="ref15">15</xref>]. With the growing popularity, smartwatches provide the possibility for continuous, real-time monitoring and feedback, which have been shown effective in increasing physical activity engagement [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref12">12</xref>-<xref ref-type="bibr" rid="ref16">16</xref>]. Nowadays, various types of smartwatches have been widely used in a variety of practical settings, such as physical activity programs, fitness training, physical education, and health care services [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref17">17</xref>-<xref ref-type="bibr" rid="ref19">19</xref>]. They also have great potentials to serve research purposes [<xref ref-type="bibr" rid="ref20">20</xref>,<xref ref-type="bibr" rid="ref21">21</xref>]. However, the practical applications of smartwatches (eg, in fitness training, physical education, and health care services) as well as their use in research should rely on continuous validation and improvement of their accuracy.</p><p>Several studies have evaluated the accuracy of various smartwatch models in real-world settings, comparing them against established activity monitoring devices such as the Accelerometer GT3X+ [<xref ref-type="bibr" rid="ref22">22</xref>,<xref ref-type="bibr" rid="ref23">23</xref>]. Degroote et al [<xref ref-type="bibr" rid="ref22">22</xref>] observed that while models such as the Polar M600 and Huawei Watch accurately measured steps, their ability to accurately capture moderate to vigorous physical activity varies. Tedesco et al [<xref ref-type="bibr" rid="ref23">23</xref>] found that for older adult population, both the Fitbit Charge 2 and the Garmin Vivosmart HR+ were effective in step counting but only moderately accurate in measuring activity energy expenditure and sleep, with Fitbit performing slightly better in these areas. In addition, several studies examined the accuracy of smartwatches in different age groups in laboratory setting [<xref ref-type="bibr" rid="ref24">24</xref>,<xref ref-type="bibr" rid="ref25">25</xref>]. Chow and Yang [<xref ref-type="bibr" rid="ref24">24</xref>] found that when performing aerobic exercise indoors, the Xiaomi Mi Band 2 and Garmin Vivosmart HR+ showed overall acceptable accuracy in heart rate measurements, which were independent of age. Magistro et al [<xref ref-type="bibr" rid="ref25">25</xref>] suggested that the ADAMO Care Watch, with its algorithm tailored for slower pace, might be particularly effective for older adults in step counting.</p><p>While the accuracy of smartwatches has been explored in previous research studies, research specifically focusing on their performance across different age groups in a free-living environment remains scarce. The Huawei smartwatch ranks second in global sales in Q2 2023 and holds a high market share of 39% in China [<xref ref-type="bibr" rid="ref26">26</xref>] but received limited empirical research attention on its accuracy [<xref ref-type="bibr" rid="ref22">22</xref>,<xref ref-type="bibr" rid="ref27">27</xref>], especially with regard to measurements of activity energy expenditure and sleep duration [<xref ref-type="bibr" rid="ref28">28</xref>-<xref ref-type="bibr" rid="ref30">30</xref>]. Considering its significant market prominence, it is crucial to rigorously assess the accuracy of the Huawei smartwatch in measuring health-related indices to ensure its validity for users&#x2019; health monitoring and lifestyle management. Clearly, researchers have long voiced out the need to regularly examine the accuracy of smartwatches in order to continuously improve their functions and better apply them to human health promotion. However, it appears that studies of validity examination are far from providing sufficient evidence that support the use of smartwatches for research and health promotion purposes [<xref ref-type="bibr" rid="ref23">23</xref>,<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref31">31</xref>].</p><p>Hence, this study aimed to determine the validity of Huawei Watch GT2 for different populations under free-living conditions. Such efforts aimed to address the lack of evidence regarding the device&#x2019;s performance across diverse user groups and provided insights that may have facilitated the broader adoption of smartwatches in health promotion and monitoring.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Participants</title><p>Sample size estimation was performed using G*Power 3.1 (effect size <italic>f</italic>&#x00B2;=0.30, &#x03B1;=.05, and power=0.80), resulting in a required sample size of 84. A total of 120 adults were recruited through campus and community flyers. Eighteen participants opted out, claiming interference with their daily life and sleep caused by the device. Ultimately, data were retained for 102 participants, including 44 young adults (YAs; age range: 18&#x2010;24 years) and 58 middle-aged and older (MAAO) adults (age range: 55&#x2010;91 years). All the participants were Chinese, living in Hangzhou, China, and volunteered to participate in this study. The inclusion criteria were no neurological or cardiovascular disease that could affect the participants&#x2019; daily exercise and no history of lower extremity injury or disability. A detailed verbal explanation was provided by the researchers before participation in the study; all participants signed informed consent. Participants had the right to choose to continue or discontinue their participation at any time during the conduct of this experiment.</p></sec><sec id="s2-2"><title>Measures</title><sec id="s2-2-1"><title>Accelerometer</title><p>The Actigraph GT3X+ (ActiGraph) has been widely used as a reference measure of physical activity because it has been consistently found to be both reliable and valid in physical activity studies [<xref ref-type="bibr" rid="ref32">32</xref>-<xref ref-type="bibr" rid="ref34">34</xref>]. The Actigraph accelerometer was set to collect data every 10 seconds, and the raw data and clinical reports of the accelerometer were downloaded using ActiLife software (version 6.13.4; ActiGraph). The Freedson Adult (1998) cut points were used to process the data and calculate activity energy expenditure [<xref ref-type="bibr" rid="ref35">35</xref>-<xref ref-type="bibr" rid="ref37">37</xref>]. The total sleep time (TST) was calculated using the Cole-Kripke algorithm [<xref ref-type="bibr" rid="ref38">38</xref>].</p></sec><sec id="s2-2-2"><title>Wearable Devices</title><p>The study aimed to examine the validity of the then-latest Huawei Watch GT2 (45.9&#x00D7;45.9&#x00D7;10.7 mm), developed by Huawei Technologies Co, in daily life. The GT2 had a wrist coverage of 14&#x2010;21 cm and was equipped with the wearable chip Kirin A1 and sensors, including an acceleration sensor, a gyroscope, an optical heart rate sensor, and a geomagnetic sensor. At the time of the study, the device was capable of measuring activity energy expenditure, step count (SC), heart rate, and sleep monitoring. In this study, the researcher used Huawei Sports Health software (Huawei Technologies Co) for data acquisition, which was conducted in 2021, to examine the performance of the GT2 in terms of SC, total daily activity energy expenditure (TDAEE), and TST in daily life.</p></sec></sec><sec id="s2-3"><title>Data Collection Procedure</title><p>The researchers measured and collected participants&#x2019; physiological data (age, gender, height, and weight) on the first day using mechanical height gauges and electronic scales and then fitted them with a calibrated Actigraph GT3X+ (right hip) and Huawei Watch GT2 (nondominant wrist). Participants were told to maintain a normal daily routine but to wear both devices for 7 consecutive days (including 2 weekends and 5 workdays). The devices were worn at all times, except during water-based activities.</p></sec><sec id="s2-4"><title>Statistical Analysis</title><p>The data were downloaded and recorded once the devices were returned. To ensure that the collected data were reliable, the researchers examined the data and excluded cases where the accelerometer was worn for less than 10 hours in a day and for fewer than 2 days [<xref ref-type="bibr" rid="ref39">39</xref>,<xref ref-type="bibr" rid="ref40">40</xref>]. Data analysis and graphical representation were performed using IBM SPSS 29 (IBM Corp) and GraphPad Prism 9 (GraphPad). First, a descriptive analysis of the GT2 and GT3X+ accelerometers was performed, and the Shapiro-Wilk test showed that the collected data followed a normal distribution (<italic>P</italic>&#x003E;.05). Second, the correlations between GT2 and accelerometer data were examined by calculating the Pearson product-moment correlation coefficient (PPMCC) and the intraclass correlation coefficient (ICC; 2-way random, absolute consistency; 95% CI; and single measurement). The critical values for the explanatory ICC were categorized as poor for &#x003C;0.60, moderate for 0.60-0.75, good for 0.75-0.90, and excellent for &#x003E;0.90 [<xref ref-type="bibr" rid="ref41">41</xref>]. Third, the agreement between GT2 and accelerometer was examined by calculating the mean percentage error (MPE) and the mean absolute percentage error (MAPE). The MPE quantifies the average percentage deviation between the GT2 and accelerometer, highlighting potential systematic discrepancies. Moreover, MAPE captures the absolute extent of these deviations, offering a comprehensive view of error magnitude without directional bias (the formula is: MAPE = (1/n) &#x00D7; &#x03A3;(|(Actual value &#x2212; Predicted value)|/Actual value) &#x00D7; 100%). These metrics are instrumental in assessing the GT2&#x2019;s precision across various physical activities. To determine whether the measurement errors of the GT2 against the Actigraph were statistically different between the 2 age groups, two-tailed independent <italic>t</italic> tests were used. Finally, to test the level of consistency between GT2 and convergence measures, Bland-Altman plots and the associated consistency restrictions were constructed. To intuitively display the accuracy of different indicators of the Huawei Watch GT2, Bull&#x2019;s-eye diagrams based on the Actigraph accelerometer were constructed.</p></sec><sec id="s2-5"><title>Ethical Considerations</title><p>This study involving human participants was rigorously reviewed and approved by the ethics committee of the Department of Psychology and Behavioral Sciences, Zhejiang University ([2021]007). All study procedures adhered to the 1964 Declaration of Helsinki and its subsequent amendments, ensuring compliance with ethical standards. Written informed consent was obtained from all participants, with strong measures in place to safeguard personal data and privacy.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Overview</title><p>A total of 102 participants met the inclusion criteria and participated in the experiment, spanning an age range of 18-91 (mean 48.17, SD 24.56) years and a BMI range of 16.68-31.64 (mean 22.52, SD 3.13) kg/m&#x00B2;. The cohort was stratified into 2 age groups: YAs and MAAO adults, with a note that 5 participants in the MAAO group were younger than 60 years, constituting 8.62% (5/58) of this group. Detailed demographic data are shown in <xref ref-type="table" rid="table1">Table 1</xref>.</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Participant characteristics (N=102).</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Characteristic</td><td align="left" valign="bottom">Total (N=102)</td><td align="left" valign="bottom">YAs<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup> (n=44)</td><td align="left" valign="bottom">MAAO<sup><xref ref-type="table-fn" rid="table1fn2">b</xref></sup> (n=58)</td></tr></thead><tbody><tr><td align="left" valign="top">Age (year), mean (SD)</td><td align="left" valign="top">48.17 (24.56)</td><td align="left" valign="top">20.89 (1.66)</td><td align="left" valign="top">68.86 (7.55)</td></tr><tr><td align="left" valign="top">Male gender, n (%)</td><td align="left" valign="top">37 (36.27)</td><td align="left" valign="top">22 (50)</td><td align="left" valign="top">15 (25.86)</td></tr><tr><td align="left" valign="top">Height (cm), mean (SD)</td><td align="left" valign="top">164.51 (8.57)</td><td align="left" valign="top">170.59 (7.38)</td><td align="left" valign="top">159.91 (6.25)</td></tr><tr><td align="left" valign="top">Weight (kg), mean (SD)</td><td align="left" valign="top">60.88 (9.07)</td><td align="left" valign="top">60.82 (8.53)</td><td align="left" valign="top">60.93 (9.54)</td></tr><tr><td align="left" valign="top">BMI (kg/m<sup>2</sup>), mean (SD)</td><td align="left" valign="top">22.52 (3.13)</td><td align="left" valign="top">20.86 (2.14)</td><td align="left" valign="top">23.78 (3.19)</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>YA: young adult.</p></fn><fn id="table1fn2"><p><sup>b</sup>MAAO: middle-aged and older.</p></fn></table-wrap-foot></table-wrap><p><xref ref-type="table" rid="table2">Table 2</xref> shows the results of correlational analysis between the GT2 and the GT3X+ accelerometer, while <xref ref-type="table" rid="table3">Table 3</xref> shows the results of the difference test between the GT2 and Actigraph in terms of SC, TDAEE, and TST during daily life across different age groups, along with the Bland-Altman limits of agreement. <xref ref-type="fig" rid="figure1">Figure 1</xref> visualizes the Bland-Altman analysis comparison plot, and <xref ref-type="fig" rid="figure2">Figure 2</xref> illustrates the overall accuracy of the Huawei Watch GT2 across various functions.</p><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Correlation coefficients, 95% CIs between Huawei Watch GT2 and Actigraph GT3X+ measurements, and independent sample <italic>t</italic> tests on mean absolute percentage error between the YA<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup> and MAAO<sup><xref ref-type="table-fn" rid="table2fn2">b</xref></sup> groups.</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Indicator, group</td><td align="left" valign="bottom" colspan="2">Correlation</td><td align="left" valign="bottom" colspan="2">Correlation</td><td align="left" valign="bottom" colspan="2">Independent</td></tr><tr><td align="left" valign="bottom"/><td align="left" valign="bottom">PPMCC<sup><xref ref-type="table-fn" rid="table2fn3">c</xref></sup> (95% CI&#xFF09;</td><td align="left" valign="bottom"><italic>P</italic> value</td><td align="left" valign="bottom">ICC<sup><xref ref-type="table-fn" rid="table2fn4">d</xref></sup> (95% CI&#xFF09;</td><td align="left" valign="bottom"><italic>P</italic> value</td><td align="left" valign="bottom"><italic>t</italic> test (<italic>df</italic>)<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="bottom"><italic>P</italic> value</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="5">SC<sup><xref ref-type="table-fn" rid="table2fn6">f</xref></sup></td><td align="left" valign="top">&#x2212;3.45 (571)</td><td align="left" valign="top">&#x003C;.001</td></tr><tr><td align="left" valign="top">&#x2003;Total</td><td align="left" valign="top">0.92 (0.91 to 0.93)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.88 (0.76 to 0.93)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;YAs</td><td align="left" valign="top">0.91 (0.89 to 0.93)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.88 (0.79 to 0.92)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;MAAO</td><td align="left" valign="top">0.92 (0.90 to 0.94)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.88 (0.73 to 0.93)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="5">TDAEE<sup><xref ref-type="table-fn" rid="table2fn7">g</xref></sup></td><td align="left" valign="top">&#x2212;6.70 (512)</td><td align="left" valign="top">&#x003C;.001</td></tr><tr><td align="left" valign="top">&#x2003;Total</td><td align="left" valign="top">0.77 (0.74 to 0.80)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.75 (0.67 to 0.80)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;YAs</td><td align="left" valign="top">0.80 (0.75 to 0.84)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.76 (0.67 to 0.83)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;MAAO</td><td align="left" valign="top">0.76 (0.71 to 0.80)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.73 (0.65 to 0.80)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="5">TST<sup><xref ref-type="table-fn" rid="table2fn8">h</xref></sup></td><td align="left" valign="top">1.54 (483)</td><td align="left" valign="top">.12</td></tr><tr><td align="left" valign="top">&#x2003;Total</td><td align="left" valign="top">0.47 (0.40 to 0.54)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.25 (&#x2212;0.06 to 0.49)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;YAs</td><td align="left" valign="top">0.49 (0.38 to 0.59)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.21 (&#x2212;0.07 to 0.46)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top">&#x2003;MAAO</td><td align="left" valign="top">0.48 (0.39 to 0.57)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top">0.29 (&#x2212;0.05 to 0.54)</td><td align="left" valign="top">&#x003C;.001</td><td align="left" valign="top"/><td align="left" valign="top"/></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>YA: young adult.</p></fn><fn id="table2fn2"><p><sup>b</sup>MAAO: middle-aged and older.</p></fn><fn id="table2fn3"><p><sup>c</sup>PPMCC: Pearson product-moment correlation coefficient.</p></fn><fn id="table2fn4"><p><sup>d</sup>ICC: intraclass coefficient correlation. &#x003C;0.60 (poor), 0.60-0.75 (moderate), 0.75-0.90 (good), and &#x003E;0.90 (excellent).</p></fn><fn id="table2fn5"><p><sup>e</sup>Independent <italic>t</italic> test: independent samples <italic>t</italic> test between YA and MAAO group mean absolute percentage errors.</p></fn><fn id="table2fn6"><p><sup>f</sup>SC: step count.</p></fn><fn id="table2fn7"><p><sup>g</sup>TDAEE: total daily activity energy expenditure.</p></fn><fn id="table2fn8"><p><sup>h</sup>TST: total sleep time.</p></fn></table-wrap-foot></table-wrap><table-wrap id="t3" position="float"><label>Table 3.</label><caption><p>Measured mean, mean percentage error (MPE), mean absolute percentage error (MAPE), and deviation values in Bland-Altman analysis for the Huawei Watch GT2 and Actigraph GT3X+ accelerometer for step count (SC; steps), total daily activity energy expenditure (TDAEE; kcal), and total sleep time (TST; minutes), with associated SDs.</p></caption><table id="table3" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Indicator, group, device</td><td align="left" valign="bottom">Mean (SD&#xFF09;</td><td align="left" valign="bottom">MPE (SD)</td><td align="left" valign="bottom">MAPE (SD&#xFF09;</td><td align="left" valign="bottom">Bland-Altman analysis<sup><xref ref-type="table-fn" rid="table3fn1">a</xref></sup>, bias (SD)</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="5">SC</td></tr><tr><td align="left" valign="top" colspan="2">&#x2003;Total</td><td align="left" valign="top">&#x2212;17.47 (30.56)</td><td align="left" valign="top">25.77 (23.98)</td><td align="left" valign="top">&#x2212;1318.82 (2340)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">9585.29 (5947.50)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">8266.47 (4919.71)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;YAs<sup><xref ref-type="table-fn" rid="table3fn2">b</xref></sup></td><td align="left" valign="top">&#x2212;14.55 (27.80)</td><td align="left" valign="top">21.91 (22.43)</td><td align="left" valign="top">&#x2212;1068.63 (2153)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">8870.82 (5333.84)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">7802.18 (4418.34)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;MAAO<sup><xref ref-type="table-fn" rid="table3fn3">c</xref></sup></td><td align="left" valign="top">&#x2212;19.79 (32.44)</td><td align="left" valign="top">28.81 (24.74)</td><td align="left" valign="top">&#x2212;1516.62 (2463)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">10,150.17 (6342.52)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">8633.55 (5260.39)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="5">TDAEE</td></tr><tr><td align="left" valign="top" colspan="2">&#x2003;Total</td><td align="left" valign="top">8.43 (39.64)</td><td align="left" valign="top">33.79 (22.34)</td><td align="left" valign="top">50.36 (148.40)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">307.76 (204.37)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">358.13 (232.90)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;YAs</td><td align="left" valign="top">4.48 (36.94)</td><td align="left" valign="top">30.32 (21.48)</td><td align="left" valign="top">44.39 (126.60)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">282.41 (172.53)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">326.80 (212.99)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;MAAO</td><td align="left" valign="top">11.32 (41.33)</td><td align="left" valign="top">36.29 (22.68)</td><td align="left" valign="top">54.73 (162.50)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">326.27 (223.26)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">381.00 (244.24)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="5">TST</td></tr><tr><td align="left" valign="top" colspan="2">&#x2003;Total</td><td align="left" valign="top">19.98 (18.20)</td><td align="left" valign="top">23.29 (13.71)</td><td align="left" valign="top">138.08 (123.80)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">476.68 (88.45)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">614.76 (138.20)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;YAs</td><td align="left" valign="top">22.13 (17.23)</td><td align="left" valign="top">24.39 (13.84)</td><td align="left" valign="top">156.33 (133.00)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">466.60 (77.06)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">622.94 (153.17)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top" colspan="2">&#x2003;MAAO</td><td align="left" valign="top">18.35 (18.77)</td><td align="left" valign="top">22.45 (13.58)</td><td align="left" valign="top">123.15 (114.70)</td></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Watch GT2</td><td align="left" valign="top">484.37 (95.68)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr><tr><td align="left" valign="top"><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content><named-content content-type="indent">&#x00A0;&#x00A0;&#x00A0;&#x00A0;</named-content>Accelerometer</td><td align="left" valign="top">608.52 (125.51)</td><td align="left" valign="top"/><td align="left" valign="top"/><td align="left" valign="top"/></tr></tbody></table><table-wrap-foot><fn id="table3fn1"><p><sup>a</sup>Bland-Altman analysis: bias of Bland-Altman.</p></fn><fn id="table3fn2"><p><sup>b</sup>YA: young adult.</p></fn><fn id="table3fn3"><p><sup>c</sup>MAAO: middle-aged and older.</p></fn></table-wrap-foot></table-wrap><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Bland-Altman plots of the Huawei Watch GT2 and Actigraph GT3X+ in overall phases for different groups and indicators. The middle line represents the mean difference between the GT2 and accelerometer (negative values indicate an overestimation of the GT2, whereas positive values indicate an underestimation), and the upper and lower dashed lines indicate the limit of agreement (1.96 &#x00D7; SD of the difference scores). The green dots indicate YAs, and the red dots indicate MAAOs. Panel A displays the Bland-Altman plot for step count (steps) across different groups, panel B presents the Bland-Altman plot for total daily activity energy expenditure (kcal) across different groups, and panel C illustrates the Bland-Altman plot for total sleep time (minutes) across different groups. MAAO: middle-aged and older adults; YA: young adults.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v8i1e59521_fig01.png"/></fig><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>Bull&#x2019;s-eye diagrams with Actigraph GT3X+ as the reference measure. The x-axis represents the MPE, and the y-axis represents the ICC between the GT2 and the accelerometer. The good accuracy of the Huawei Watch GT2&#x2019;s measurement is indicated when the scatter point falls steadily near the origin (MPE=0, ICC=1). ICC: intraclass correlation coefficient; MPE: mean percentage error; SC: step count (steps); TDAEE: total daily activity energy expenditure (kcal); TST: total sleep time (minutes).</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="formative_v8i1e59521_fig02.png"/></fig></sec><sec id="s3-2"><title>Step Count</title><p>First, <xref ref-type="table" rid="table2">Table 2</xref> shows the correlation between the GT2 and the accelerometer, with a PPMCC test score of 0.92 (<italic>P</italic>&#x003C;.001; 95% CI 0.91-0.93) and an ICC test score of 0.88 (<italic>P</italic>&#x003C;.001; 95% CI 0.76-0.93), which suggests that the GT2 possesses good to excellent validity in measuring SC. Second, the difference between the GT2 and Actigraph in SC across age groups is shown in <xref ref-type="table" rid="table3">Table 3</xref>. Generally, the GT2 tends to overestimate SC compared with Actigraph accelerometer measurements (MPE=&#x2212;17.47%, mean difference [MD]=1318.82 steps). This overestimation is more pronounced in the MAAO group (MPE=&#x2212;19.79%, MD=1516.62 steps) than in the YA group (MPE=&#x2212;14.55%, MD=1068.63 steps). Furthermore, the error results (MPE=&#x2212;17.47%, MAPE=25.77%) confirm the GT2&#x2019;s validity for measuring SC in daily life. A independent <italic>t</italic> test comparing MAPE between the YA and MAAO groups indicates a significant difference (<italic>t</italic>=&#x2212;3.45; <italic>df</italic>=571; <italic>P</italic>&#x003C;.001), with the YA group showing a lower measurement error (MAPE=21.91%, SD=22.43%) than the MAAO group (MAPE=28.81%, SD=24.74). Finally, the Bland-Altman plot and Bull&#x2019;s-eye diagrams (<xref ref-type="fig" rid="figure1">Figures 1A</xref> and <xref ref-type="fig" rid="figure2">2</xref>) display minimal scatter bias, suggesting good overall consistency in GT2&#x2019;s SC measurements. However, as the number of steps increases, the deviation becomes greater, implying a decrease in measurement consistency between the GT2 and the Actigraph (<xref ref-type="fig" rid="figure1">Figure 1A</xref>). Overall, the GT2 demonstrates good to excellent accuracy in SC measurement for both YA and MAAO groups in daily life settings.</p></sec><sec id="s3-3"><title>Total Daily Activity Energy Expenditure</title><p>First, <xref ref-type="table" rid="table2">Table 2</xref> illustrates that TDAEE data measured by the GT2 and the accelerometer are correlated, evidenced by a PPMCC of 0.77 (<italic>P</italic>&#x003C;.001; 95% CI 0.74-0.80) and an ICC of 0.75 (<italic>P</italic>&#x003C;.001; 95% CI 0.67-0.80), indicating GT2&#x2019;s moderate to good validity in measuring TDAEE. Second, <xref ref-type="table" rid="table3">Table 3</xref> summarizes the agreements between the GT2 and Actigraph in terms of TDAEE during daily life in different groups. In daily settings, GT2 typically underestimates TDAEE (MPE=8.43%, MD=50.36 kcal) compared with the Actigraph accelerometer. The underestimation seems to be more frequent among MAAO adults (MPE=11.32%, MD=54.73 kcal) than among YAs (MPE=4.48%, MD=44.39 kcal). The error results (MPE=8.43%, MAPE=33.79%) suggest moderate validity of the GT2 for measuring TDAEE in daily life. A independent <italic>t</italic> test comparing MAPE between the YA and MAAO groups showed a significant difference (<italic>t</italic>=&#x2212;6.70; <italic>df</italic>=512; <italic>P</italic>&#x003C;.001), with the YA group exhibiting a lower measurement error (MAPE=30.32%, SD=21.48%) than the MAAO group (MAPE=36.29%, SD=22.68%). Finally, the Bland-Altman plot and Bull&#x2019;s-eye diagrams (<xref ref-type="fig" rid="figure1">Figures 1B</xref> and <xref ref-type="fig" rid="figure2">2</xref>) indicate moderate consistency in GT2&#x2019;s TDAEE measurements, with a tendency to underestimate. In addition, the bias increases with increasing levels of TDAEE, suggesting that the error in GT2 measurements tends to amplify as activity energy expenditure increases (<xref ref-type="fig" rid="figure1">Figure 1B</xref>). Overall, the GT2 has moderate validity and may have limited measurement accuracy at high levels of activity energy expenditure.</p></sec><sec id="s3-4"><title>Total Sleep Time</title><p>First, <xref ref-type="table" rid="table2">Table 2</xref> displays a significant correlation between the GT2 and the accelerometer, with a PPMCC of 0.47 (<italic>P</italic>&#x003C;.001; 95% CI 0.40-0.54) and an ICC test score of 0.25 (<italic>P</italic>&#x003C;.001; 95% CI &#x2212;0.06 to 0.49). Second, we tested the difference between GT2 and Actigraph in terms of TST during daily life across different age groups, which is summarized in <xref ref-type="table" rid="table3">Table 3</xref>. The GT2 tends to underestimate TST (MPE=19.98%, MD=138.08 minutes) as compared with the Actigraph accelerometer measurements. The underestimation was evident between both YAs (MPE=22.13%, MD=156.33 minutes) and MAAO adults (MPE=18.35%, MD=123.15 minutes). The error results (MPE=19.98%, MAPE=23.29%) suggest moderate validity of the GT2 for measuring TST in daily life. A independent <italic>t</italic> test showed no significant difference in MAPE between the YA and MAAO groups (<italic>t</italic>=1.54; <italic>df</italic>=483; <italic>P</italic>=.12), indicating that the measurement error of the GT2 in the YA group (MAPE=24.39%, SD=13.84%) was comparable with that in the MAAO group (MAPE=22.45%, SD=13.58%). Finally, the Bland-Altman plots and Bull&#x2019;s-eye diagrams (<xref ref-type="fig" rid="figure1">Figures 1C</xref> and <xref ref-type="fig" rid="figure2">2</xref>) indicate that the GT2 tends to underestimate TST and that the underestimation increases as sleep time increases. Overall, when using the Actigraph GT3X+ as the criterion measure, the GT2 has poor to moderate validity in measuring TST among adults during daily life.</p></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Principal Findings</title><p>This study assessed the accuracy of the Huawei Watch GT2 in measuring SC, TDAEE, and TST under free-living conditions, while also exploring the validity differences between YAs and MAAO adults. The findings indicate that while the GT2 measures SC reasonably accurately, its accuracy in measuring TDAEE is lower, especially at higher levels of TDAEE. In addition, the accuracy of TST measurement appears to be lower when using Actigraph accelerometers as the reference criterion, highlighting the need for more valid standardized measures for further validation. Notably, the GT2 demonstrated higher accuracy in measuring SC and TDAEE in the YA group than in the MAAO group; however, the measurement errors for TST did not significantly differ between the 2 age groups.</p><p>For SC, the GT2 often reports higher counts than traditional accelerometers in daily scenarios (MD=1318 steps), yet it maintains a reasonable accuracy in SC, as evidenced by its high ICC value with accelerometer counts (ICC=0.88). This observation is in line with findings from prior research. For instance, Degroote et al [<xref ref-type="bibr" rid="ref22">22</xref>] found that despite the Huawei watch&#x2019;s tendency to overestimate SC (MD=1478 steps), its SC measurement accuracy remains robust, demonstrated by strong correlations with accelerometer data (ICC=0.88). The consistent overestimation observed across studies may be attributed to the differing placement of the devices [<xref ref-type="bibr" rid="ref22">22</xref>,<xref ref-type="bibr" rid="ref42">42</xref>]. Tudor-Locke et al [<xref ref-type="bibr" rid="ref42">42</xref>] showed that wrist-attached devices tend to report higher SC than waist-attached devices in free-living conditions, with overestimations ranging from 2500 to 8700 steps per day. This phenomenon is particularly noticeable during sedentary and low-intensity intermittent activities, which are more prevalent than continuous walking in everyday life [<xref ref-type="bibr" rid="ref43">43</xref>]. Consequently, while the GT2 accurately captures SC during regular walking (involving typical wrist and hip movements), it may also mistakenly count steps during wrist movements in nonwalking activities (eg, wrist oscillation without actual displacement), leading to higher counts than those recorded by waist-worn accelerometers. Further analysis through a independent <italic>t</italic> test on MAPE revealed that the GT2&#x2019;s SC performance is superior in the YA group (MAPE=21.91%) compared with the MAAO group (MAPE=28.81%). This can be attributed to YAs&#x2019; more predictable movement patterns, which correspond more closely with the GT2&#x2019;s step counting algorithm [<xref ref-type="bibr" rid="ref43">43</xref>]. In addition, younger adults typically engage more in vigorous activities, making their movements more detectable than those of older adults, resulting in better accuracy for the GT2. This is in line with previous research indicating that consumer-grade activity trackers tend to be more accurate at moderate to vigorous walking speeds than at slower speeds [<xref ref-type="bibr" rid="ref44">44</xref>]. Future studies may consider improving the calibration of SC algorithms in smartwatches to account for the variability in activity types and intensities, which may potentially enhance their accuracy across a wider range of movements.</p><p>To our knowledge, this is the first study to assess the GT2 smartwatch&#x2019;s efficacy in measuring TDAEE in real-life settings. Consistent with findings from other smartwatch research on TDAEE [<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref45">45</xref>-<xref ref-type="bibr" rid="ref48">48</xref>], our results reveal that while the GT2 demonstrates moderate validity compared with the Actigraph, its accuracy in TDAEE measurements is still not ideal, as indicated by a high level of errors against the Actigraph (MAPE &#x003E;30%). Previously, Le et al [<xref ref-type="bibr" rid="ref27">27</xref>] analyzed the accuracy of GT2 compared with Cosmed K5 in measuring activity energy expenditure in outdoor scenarios and showed that the ICC was 0.76 and 0.68, and the MAPE was 9.9% and 11.9% in walking (6 km/hour, 2 km) and running (10 km/hour, 2 km) scenarios, respectively. These findings underscore the GT2&#x2019;s moderate accuracy in activity energy expenditure measurement. Notably, our study extends the current findings by highlighting an increase in measurement error according to the rise in activity energy expenditure. Although the degree of error in our study appears higher than that reported in previous studies (eg, Le et al [<xref ref-type="bibr" rid="ref27">27</xref>], Muggeridge et al [<xref ref-type="bibr" rid="ref49">49</xref>], and Reddy et al [<xref ref-type="bibr" rid="ref50">50</xref>]), we applied the device in a real-world setting over an extended period of 7 full days. It is important to consider that acceptable MAPE limits should be interpreted in the context of specific application scenarios and performance indicators. Previous research has shown that data collected in daily life are often less accurate than those generated under standardized, controlled, and relatively short-term conditions, such as in a laboratory setting [<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref45">45</xref>,<xref ref-type="bibr" rid="ref51">51</xref>]. This is because the accuracy of the device in real-world scenarios can be influenced by various factors, such as complex terrain and irregular activity patterns, which make it challenging to consistently identify such activities through acceleration counts [<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref51">51</xref>]. Hence, scholars have clearly articulated the necessity of testing devices in free-living contexts, as they are designed to monitor daily living activities [<xref ref-type="bibr" rid="ref52">52</xref>]. Again, this study emphasized that while the GT2 has good potentials for everyday health monitoring, users and researchers alike must remain cognizant of its limitations in accurately tracking TDAEE. The Huawei Watch GT2 may face challenges in accurately predicting energy expenditure in certain scenarios, especially when activity patterns are not very consistent. To address this, it is critical to further enhance sensor accuracy and better integrate multiple data sources, optimizing the algorithm&#x2019;s ability to recognize and monitor activity patterns. The users should take the potential underestimation into consideration when interpreting the readings of their TDAEE. Such findings underscore the ongoing need for technological refinement and validation.</p><p>Likewise, the issue of the measurement error in TST by GT2 warrants further research attention. We identified an underestimation of TST (138.08 minutes) for the GT2, and a similar case is reported on Fitbit [<xref ref-type="bibr" rid="ref53">53</xref>,<xref ref-type="bibr" rid="ref54">54</xref>]. Compared with polysomnography, Meltzer et al [<xref ref-type="bibr" rid="ref53">53</xref>] showed that the Fitbit Ultra (sensitive mode) underestimated TST by 105 minutes on average in youth, and Cook et al [<xref ref-type="bibr" rid="ref54">54</xref>] also found that the Fitbit Flex (sensitive mode) underestimated TST (86.3 minutes) in individuals with unipolar major depressive disorder. The degree of TST underestimation of Fitbit seems smaller than what we found in GT2. However, the reference measure used in this study (the accelerometer) is different from that used in Fitbit validation studies (polysomnography). Polysomnography is the gold standard for TST measurement, whereas accelerometers often overestimate TST too. For instance, Zinkhan et al [<xref ref-type="bibr" rid="ref55">55</xref>] found that Actigraph GT3X+ (hip) overestimated TST (81.1 minutes) as compared with polysomnography. Therefore, when hip-worn accelerometers are used as measurement criteria, the degree of underestimating TST by smartwatch is likely to be exaggerated [<xref ref-type="bibr" rid="ref55">55</xref>,<xref ref-type="bibr" rid="ref56">56</xref>]. It is worth noting that different wearing positions resulting in different displacement data may be one of the reasons why the accelerometer and GT2 data are not in agreement [<xref ref-type="bibr" rid="ref42">42</xref>,<xref ref-type="bibr" rid="ref55">55</xref>]. Specifically, during bed rest, wrist activity tends to be higher than hip activity, given that people may engage in activities involving use of wrists (eg, reading books or using a mobile phone); in fact, many participants orally reported habitual use of smartphones while lying in bed prior to falling asleep at night and getting up in the morning. In such cases, it is easy for smartwatch to capture wrist movements and accurately distinguish between awake and sleep states. However, hip-worn accelerometers are less able to monitor these activities and tend to recognize them as sleep time and therefore are more likely to overestimate sleep duration, especially in insomniacs [<xref ref-type="bibr" rid="ref55">55</xref>]. As described in the reviews by Guillodo et al [<xref ref-type="bibr" rid="ref57">57</xref>] and Evenson et al [<xref ref-type="bibr" rid="ref45">45</xref>], the current evidence from reliability studies on sleep is still limited. Therefore, although results of this study suggest that the GT2 is likely to underestimate TST in reference to Actigraph, we should be cautious in drawing the conclusions. Future research is essential, and it should incorporate established standards such as polysomnography to validate the accuracy of smartwatch measurements for TST.</p><p>Smartwatches are becoming increasingly popular, but their use for monitoring and regulating health-related behaviors (eg, physical activity, sedentary behaviors, and sleep) is hindered by insufficient evidence of accuracy [<xref ref-type="bibr" rid="ref23">23</xref>,<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref31">31</xref>]. In particular, the accuracy of the Huawei Watch GT2, a highly popular wearable device, remains uncertain in terms of TDAEE and TST monitoring in daily life, and few studies have been conducted on large Asian populations [<xref ref-type="bibr" rid="ref28">28</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref31">31</xref>]. Therefore, we focused on gathering empirical evidence on the GT2&#x2019;s accuracy in the Chinese population, we believe such efforts are necessary and should be made on a regular basis. In this study, we found that the GT2 demonstrates good accuracy in measuring SC in adults during daily life but requires improvement in measuring TDAEE and TST. In addition, the accuracy of the GT2 in measuring SC and TDAEE may vary across different populations. Users should consider potential bias when evaluating activity goals based on GT2 measurements. This is particularly important to many users (especially those managing chronic diseases or aiming to improve physical health and well-being) who rely on the real-time feedback provided by smartwatches [<xref ref-type="bibr" rid="ref58">58</xref>,<xref ref-type="bibr" rid="ref59">59</xref>]. Future devices should better recognize users&#x2019; behavioral habits, so that the algorithms can be improved to better account for personal characteristics. Therefore, we call on mainstream smartwatch manufacturers to continuously improve their devices by introducing advanced techniques such as deep learning and sensor fusion to refine algorithms for more accurate health monitoring. Although it is challenging to establish a one-size-fits-all measurement standard due to individual and environmental variability, studies that consistently evaluate the validity of smartwatches can offer valuable feedback to improve algorithms, increase public recognition, and ultimately enhance their potential for health behavior management and promotion.</p></sec><sec id="s4-2"><title>Strengths and Limitations</title><p>This study has several strengths. First, the Huawei Watch is a widely used smartwatch with a high market share, especially in China (39%) [<xref ref-type="bibr" rid="ref26">26</xref>], but only a few studies have provided empirical evidence of its accuracy [<xref ref-type="bibr" rid="ref22">22</xref>,<xref ref-type="bibr" rid="ref27">27</xref>]. The study examines the measurement accuracy of the GT2 in free-living settings. In particular, it is the first to examine the GT2&#x2019;s accuracy in measuring TDAEE and TST in daily life, which are quite important parameters that have not received sufficient attention. Second, this study has a sample size that is relatively large among validation studies of smartwatches and covers a wide age distribution of participants (18-24 years in YAs; 55-91 years in MAAO adults), evidence of such studies is rarely reported before [<xref ref-type="bibr" rid="ref30">30</xref>]. Collectively, the results supported the accuracy of this device in measuring SC and TDAEE in daily life. These findings may help users and researchers better determine how to use GT2 for practical and research purposes.</p><p>However, the results of this study should also be interpreted with consideration for several limitations. First, the proportion of female participants was higher in the MAAO group, and since we recruited a healthy population, the results may not be generalizable to populations with existing health conditions. Second, the reference measure of the study was research-grade accelerometers with known validity limitations, especially in terms of sleep measures. Future studies could use polysomnography and doubly labeled water methods to evaluate the accuracy of relevant parameters. Third, like other smartwatch validation studies, this study had access to only algorithmically processed data. In addition, as smartwatches are iteratively updated, the results may not generalize to newer models. Future studies should consider adopting more appropriate and feasible criterion measures based on the specific target behaviors to be assessed.</p></sec><sec id="s4-3"><title>Conclusions</title><p>In summary, the Huawei Watch GT2 serves as a valid measure of SC and shows moderate accuracy in measuring TDAEE. However, it should be used with caution for studies requiring high precision of TDAEE. Furthermore, the GT2 has been shown to underestimate TST measurements in reference to an accelerometer. Future studies should further validate its accuracy in monitoring TST using more valid methods, such as polysomnography. The GT2 demonstrated higher accuracy in measuring SC and TDAEE in the YA group compared with the MAAO group. However, the measurement errors for TST did not differ significantly between the 2 age groups. As smartwatches are constantly updated, their accuracy should be regularly evaluated in various settings and populations to ensure proper application in health-related behavior monitoring and promotion.</p></sec></sec></body><back><ack><p>The authors would like to thank all the participants for their contributions to this study. The authors would also like to thank the community workers for their active cooperation and the staff of this program for their dedication.</p></ack><fn-group><fn fn-type="conflict"><p>None declared.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">ICC</term><def><p>intraclass correlation coefficient</p></def></def-item><def-item><term id="abb2">MAAO</term><def><p>middle-aged and older</p></def></def-item><def-item><term id="abb3">MAPE</term><def><p>mean absolute percentage error</p></def></def-item><def-item><term id="abb4">MD</term><def><p>mean difference</p></def></def-item><def-item><term id="abb5">MPE</term><def><p>mean percentage error</p></def></def-item><def-item><term id="abb6">PPMCC</term><def><p>Pearson product-moment correlation coefficient</p></def></def-item><def-item><term id="abb7">SC</term><def><p>step count</p></def></def-item><def-item><term id="abb8">TDAEE</term><def><p>total daily activity energy expenditure</p></def></def-item><def-item><term id="abb9">TST</term><def><p>total sleep time</p></def></def-item><def-item><term id="abb10">YA</term><def><p>young adult</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Booth</surname><given-names>FW</given-names> </name><name name-style="western"><surname>Roberts</surname><given-names>CK</given-names> </name><name name-style="western"><surname>Laye</surname><given-names>MJ</given-names> </name></person-group><article-title>Lack of exercise is a major cause of chronic diseases</article-title><source>Compr Physiol</source><year>2012</year><month>04</month><volume>2</volume><issue>2</issue><fpage>1143</fpage><lpage>1211</lpage><pub-id pub-id-type="doi">10.1002/cphy.c110025</pub-id><pub-id pub-id-type="medline">23798298</pub-id></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>IM</given-names> </name><name name-style="western"><surname>Shiroma</surname><given-names>EJ</given-names> </name><name name-style="western"><surname>Lobelo</surname><given-names>F</given-names> </name><etal/></person-group><article-title>Effect of physical inactivity on major non-communicable diseases worldwide: an analysis of burden of disease and life expectancy</article-title><source>Lancet</source><year>2012</year><month>07</month><day>21</day><volume>380</volume><issue>9838</issue><fpage>219</fpage><lpage>229</lpage><pub-id pub-id-type="doi">10.1016/S0140-6736(12)61031-9</pub-id><pub-id pub-id-type="medline">22818936</pub-id></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cao</surname><given-names>C</given-names> </name><name name-style="western"><surname>Friedenreich</surname><given-names>CM</given-names> </name><name name-style="western"><surname>Yang</surname><given-names>L</given-names> </name></person-group><article-title>Association of daily sitting time and leisure-time physical activity with survival among US cancer survivors</article-title><source>JAMA Oncol</source><year>2022</year><month>03</month><day>1</day><volume>8</volume><issue>3</issue><fpage>395</fpage><lpage>403</lpage><pub-id pub-id-type="doi">10.1001/jamaoncol.2021.6590</pub-id><pub-id pub-id-type="medline">34989765</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kohl</surname><given-names>HW</given-names>  <suffix>3rd</suffix></name><name name-style="western"><surname>Craig</surname><given-names>CL</given-names> </name><name name-style="western"><surname>Lambert</surname><given-names>EV</given-names> </name><etal/></person-group><article-title>The pandemic of physical inactivity: global action for public health</article-title><source>Lancet</source><year>2012</year><month>07</month><day>21</day><volume>380</volume><issue>9838</issue><fpage>294</fpage><lpage>305</lpage><pub-id pub-id-type="doi">10.1016/S0140-6736(12)60898-8</pub-id><pub-id pub-id-type="medline">22818941</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Jayasinghe</surname><given-names>S</given-names> </name><name name-style="western"><surname>Byrne</surname><given-names>NM</given-names> </name><name name-style="western"><surname>Patterson</surname><given-names>KAE</given-names> </name><name name-style="western"><surname>Ahuja</surname><given-names>KDK</given-names> </name><name name-style="western"><surname>Hills</surname><given-names>AP</given-names> </name></person-group><article-title>The current global state of movement and physical activity&#x2013;the health and economic costs of the inactive phenotype</article-title><source>Prog Cardiovasc Dis</source><year>2021</year><volume>64</volume><fpage>9</fpage><lpage>16</lpage><pub-id pub-id-type="doi">10.1016/j.pcad.2020.10.006</pub-id><pub-id pub-id-type="medline">33130190</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Myers</surname><given-names>J</given-names> </name><name name-style="western"><surname>Kokkinos</surname><given-names>P</given-names> </name><name name-style="western"><surname>Arena</surname><given-names>R</given-names> </name><name name-style="western"><surname>LaMonte</surname><given-names>MJ</given-names> </name></person-group><article-title>The impact of moving more, physical activity, and cardiorespiratory fitness: why we should strive to measure and improve fitness</article-title><source>Prog Cardiovasc Dis</source><year>2021</year><volume>64</volume><fpage>77</fpage><lpage>82</lpage><pub-id pub-id-type="doi">10.1016/j.pcad.2020.11.003</pub-id><pub-id pub-id-type="medline">33160944</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Malwade</surname><given-names>S</given-names> </name><name name-style="western"><surname>Abdul</surname><given-names>SS</given-names> </name><name name-style="western"><surname>Uddin</surname><given-names>M</given-names> </name><etal/></person-group><article-title>Mobile and wearable technologies in healthcare for the ageing population</article-title><source>Comput Methods Programs Biomed</source><year>2018</year><month>07</month><volume>161</volume><fpage>233</fpage><lpage>237</lpage><pub-id pub-id-type="doi">10.1016/j.cmpb.2018.04.026</pub-id><pub-id pub-id-type="medline">29852964</pub-id></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ainsworth</surname><given-names>B</given-names> </name><name name-style="western"><surname>Cahalin</surname><given-names>L</given-names> </name><name name-style="western"><surname>Buman</surname><given-names>M</given-names> </name><name name-style="western"><surname>Ross</surname><given-names>R</given-names> </name></person-group><article-title>The current state of physical activity assessment tools</article-title><source>Prog Cardiovasc Dis</source><year>2015</year><volume>57</volume><issue>4</issue><fpage>387</fpage><lpage>395</lpage><pub-id pub-id-type="doi">10.1016/j.pcad.2014.10.005</pub-id><pub-id pub-id-type="medline">25446555</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Aparicio-Ugarriza</surname><given-names>R</given-names> </name><name name-style="western"><surname>Mielgo-Ayuso</surname><given-names>J</given-names> </name><name name-style="western"><surname>Benito</surname><given-names>PJ</given-names> </name><etal/></person-group><article-title>Physical activity assessment in the general population; instrumental methods and new technologies</article-title><source>Nutr Hosp</source><year>2015</year><month>02</month><day>26</day><volume>31 Suppl 3</volume><fpage>219</fpage><lpage>226</lpage><pub-id pub-id-type="doi">10.3305/nh.2015.31.sup3.8769</pub-id><pub-id pub-id-type="medline">25719789</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kim</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Park</surname><given-names>I</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>M</given-names> </name></person-group><article-title>Convergent validity of the international physical activity questionnaire (IPAQ): meta-analysis</article-title><source>Public Health Nutr</source><year>2013</year><month>03</month><volume>16</volume><issue>3</issue><fpage>440</fpage><lpage>452</lpage><pub-id pub-id-type="doi">10.1017/S1368980012002996</pub-id><pub-id pub-id-type="medline">22874087</pub-id></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chen</surname><given-names>KY</given-names> </name><name name-style="western"><surname>Rothney</surname><given-names>MP</given-names> </name><name name-style="western"><surname>Brychta</surname><given-names>RJ</given-names> </name></person-group><article-title>Physical activity monitors: do more sensors mean better precision?</article-title><source>J Diabetes Sci Technol</source><year>2007</year><month>09</month><volume>1</volume><issue>5</issue><fpage>768</fpage><lpage>770</lpage><pub-id pub-id-type="doi">10.1177/193229680700100523</pub-id><pub-id pub-id-type="medline">19885146</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lao</surname><given-names>C</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>B</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>RS</given-names> </name><name name-style="western"><surname>Chang</surname><given-names>H</given-names> </name></person-group><article-title>The combined effects of sports smart bracelet and multi-component exercise program on exercise motivation among the elderly in Macau</article-title><source>Medicina (Kaunas)</source><year>2021</year><month>01</month><day>2</day><volume>57</volume><issue>1</issue><fpage>34</fpage><pub-id pub-id-type="doi">10.3390/medicina57010034</pub-id><pub-id pub-id-type="medline">33401676</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Blount</surname><given-names>DS</given-names> </name><name name-style="western"><surname>McDonough</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Gao</surname><given-names>Z</given-names> </name></person-group><article-title>Effect of wearable technology-based physical activity interventions on breast cancer survivors&#x2019; physiological, cognitive, and emotional outcomes: a systematic review</article-title><source>J Clin Med</source><year>2021</year><month>05</month><day>8</day><volume>10</volume><issue>9</issue><fpage>2015</fpage><pub-id pub-id-type="doi">10.3390/jcm10092015</pub-id><pub-id pub-id-type="medline">34066752</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>McDonough</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Su</surname><given-names>X</given-names> </name><name name-style="western"><surname>Gao</surname><given-names>Z</given-names> </name></person-group><article-title>Health wearable devices for weight and BMI reduction in individuals with overweight/obesity and chronic comorbidities: systematic review and network meta-analysis</article-title><source>Br J Sports Med</source><year>2021</year><month>08</month><volume>55</volume><issue>16</issue><fpage>917</fpage><lpage>925</lpage><pub-id pub-id-type="doi">10.1136/bjsports-2020-103594</pub-id><pub-id pub-id-type="medline">33731385</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Brickwood</surname><given-names>KJ</given-names> </name><name name-style="western"><surname>Watson</surname><given-names>G</given-names> </name><name name-style="western"><surname>O&#x2019;Brien</surname><given-names>J</given-names> </name><name name-style="western"><surname>Williams</surname><given-names>AD</given-names> </name></person-group><article-title>Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis</article-title><source>JMIR Mhealth Uhealth</source><year>2019</year><month>04</month><day>12</day><volume>7</volume><issue>4</issue><fpage>e11819</fpage><pub-id pub-id-type="doi">10.2196/11819</pub-id><pub-id pub-id-type="medline">30977740</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kheirkhahan</surname><given-names>M</given-names> </name><name name-style="western"><surname>Nair</surname><given-names>S</given-names> </name><name name-style="western"><surname>Davoudi</surname><given-names>A</given-names> </name><etal/></person-group><article-title>A smartwatch-based framework for real-time and online assessment and mobility monitoring</article-title><source>J Biomed Inform</source><year>2019</year><month>01</month><volume>89</volume><fpage>29</fpage><lpage>40</lpage><pub-id pub-id-type="doi">10.1016/j.jbi.2018.11.003</pub-id><pub-id pub-id-type="medline">30414474</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sun</surname><given-names>J</given-names> </name><name name-style="western"><surname>Liu</surname><given-names>Y</given-names> </name></person-group><article-title>Using smart bracelets to assess heart rate among students during physical education lessons: feasibility, reliability, and validity study</article-title><source>JMIR Mhealth Uhealth</source><year>2020</year><month>08</month><day>5</day><volume>8</volume><issue>8</issue><fpage>e17699</fpage><pub-id pub-id-type="doi">10.2196/17699</pub-id><pub-id pub-id-type="medline">32663136</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hinde</surname><given-names>K</given-names> </name><name name-style="western"><surname>White</surname><given-names>G</given-names> </name><name name-style="western"><surname>Armstrong</surname><given-names>N</given-names> </name></person-group><article-title>Wearable devices suitable for monitoring twenty four hour heart rate variability in military populations</article-title><source>Sensors (Basel)</source><year>2021</year><month>02</month><day>4</day><volume>21</volume><issue>4</issue><fpage>1061</fpage><pub-id pub-id-type="doi">10.3390/s21041061</pub-id><pub-id pub-id-type="medline">33557190</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Beukenhorst</surname><given-names>AL</given-names> </name><name name-style="western"><surname>Parkes</surname><given-names>MJ</given-names> </name><name name-style="western"><surname>Cook</surname><given-names>L</given-names> </name><etal/></person-group><article-title>Collecting symptoms and sensor data with consumer smartwatches (the Knee OsteoArthritis, Linking Activity and Pain Study): protocol for a longitudinal, observational feasibility study</article-title><source>JMIR Res Protoc</source><year>2019</year><month>01</month><day>23</day><volume>8</volume><issue>1</issue><fpage>e10238</fpage><pub-id pub-id-type="doi">10.2196/10238</pub-id><pub-id pub-id-type="medline">30672745</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ma</surname><given-names>X</given-names> </name></person-group><article-title>Analysis of human exercise health monitoring data of smart bracelet based on machine learning</article-title><source>Comput Intell Neurosci</source><year>2022</year><volume>2022</volume><fpage>7971904</fpage><pub-id pub-id-type="doi">10.1155/2022/7971904</pub-id><pub-id pub-id-type="medline">35720918</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Beets</surname><given-names>MW</given-names> </name><name name-style="western"><surname>Bornstein</surname><given-names>D</given-names> </name><name name-style="western"><surname>Dowda</surname><given-names>M</given-names> </name><name name-style="western"><surname>Pate</surname><given-names>RR</given-names> </name></person-group><article-title>Compliance with national guidelines for physical activity in U.S. preschoolers: measurement and interpretation</article-title><source>Pediatrics</source><year>2011</year><month>04</month><volume>127</volume><issue>4</issue><fpage>658</fpage><lpage>664</lpage><pub-id pub-id-type="doi">10.1542/peds.2010-2021</pub-id><pub-id pub-id-type="medline">21422082</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Degroote</surname><given-names>L</given-names> </name><name name-style="western"><surname>De Bourdeaudhuij</surname><given-names>I</given-names> </name><name name-style="western"><surname>Verloigne</surname><given-names>M</given-names> </name><name name-style="western"><surname>Poppe</surname><given-names>L</given-names> </name><name name-style="western"><surname>Crombez</surname><given-names>G</given-names> </name></person-group><article-title>The accuracy of smart devices for measuring physical activity in daily life: validation study</article-title><source>JMIR Mhealth Uhealth</source><year>2018</year><month>12</month><day>13</day><volume>6</volume><issue>12</issue><fpage>e10972</fpage><pub-id pub-id-type="doi">10.2196/10972</pub-id><pub-id pub-id-type="medline">30545810</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tedesco</surname><given-names>S</given-names> </name><name name-style="western"><surname>Sica</surname><given-names>M</given-names> </name><name name-style="western"><surname>Ancillao</surname><given-names>A</given-names> </name><name name-style="western"><surname>Timmons</surname><given-names>S</given-names> </name><name name-style="western"><surname>Barton</surname><given-names>J</given-names> </name><name name-style="western"><surname>O&#x2019;Flynn</surname><given-names>B</given-names> </name></person-group><article-title>Validity evaluation of the Fitbit Charge2 and the Garmin vivosmart HR+ in free-living environments in an older adult cohort</article-title><source>JMIR Mhealth Uhealth</source><year>2019</year><month>06</month><day>19</day><volume>7</volume><issue>6</issue><fpage>e13084</fpage><pub-id pub-id-type="doi">10.2196/13084</pub-id><pub-id pub-id-type="medline">31219048</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chow</surname><given-names>HW</given-names> </name><name name-style="western"><surname>Yang</surname><given-names>CC</given-names> </name></person-group><article-title>Accuracy of optical heart rate sensing technology in wearable fitness trackers for young and older adults: validation and comparison study</article-title><source>JMIR Mhealth Uhealth</source><year>2020</year><month>04</month><day>28</day><volume>8</volume><issue>4</issue><fpage>e14707</fpage><pub-id pub-id-type="doi">10.2196/14707</pub-id><pub-id pub-id-type="medline">32343255</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Magistro</surname><given-names>D</given-names> </name><name name-style="western"><surname>Brustio</surname><given-names>PR</given-names> </name><name name-style="western"><surname>Ivaldi</surname><given-names>M</given-names> </name><etal/></person-group><article-title>Validation of the ADAMO Care Watch for step counting in older adults</article-title><source>PLoS One</source><year>2018</year><volume>13</volume><issue>2</issue><fpage>e0190753</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0190753</pub-id><pub-id pub-id-type="medline">29425196</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="web"><person-group person-group-type="author"><name name-style="western"><surname>Li</surname><given-names>D</given-names> </name></person-group><article-title>Huawei dominates Chinese smartwatch market in Q2 2023, Huawei Watch 4 shows power</article-title><source>HC Newsroom</source><year>2023</year><month>08</month><day>31</day><access-date>2024-12-11</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.huaweicentral.com/huawei-dominates-chinese-smartwatch-market-in-q2-2023-huawei-watch-4-shows-power/">https://www.huaweicentral.com/huawei-dominates-chinese-smartwatch-market-in-q2-2023-huawei-watch-4-shows-power/</ext-link></comment></nlm-citation></ref><ref id="ref27"><label>27</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Le</surname><given-names>S</given-names> </name><name name-style="western"><surname>Wang</surname><given-names>X</given-names> </name><name name-style="western"><surname>Zhang</surname><given-names>T</given-names> </name><etal/></person-group><article-title>Validity of three smartwatches in estimating energy expenditure during outdoor walking and running</article-title><source>Front Physiol</source><year>2022</year><volume>13</volume><fpage>995575</fpage><pub-id pub-id-type="doi">10.3389/fphys.2022.995575</pub-id><pub-id pub-id-type="medline">36225296</pub-id></nlm-citation></ref><ref id="ref28"><label>28</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fuller</surname><given-names>D</given-names> </name><name name-style="western"><surname>Colwell</surname><given-names>E</given-names> </name><name name-style="western"><surname>Low</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review</article-title><source>JMIR Mhealth Uhealth</source><year>2020</year><month>09</month><day>8</day><volume>8</volume><issue>9</issue><fpage>e18694</fpage><pub-id pub-id-type="doi">10.2196/18694</pub-id><pub-id pub-id-type="medline">32897239</pub-id></nlm-citation></ref><ref id="ref29"><label>29</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Henriksen</surname><given-names>A</given-names> </name><name name-style="western"><surname>Haugen Mikalsen</surname><given-names>M</given-names> </name><name name-style="western"><surname>Woldaregay</surname><given-names>AZ</given-names> </name><etal/></person-group><article-title>Using fitness trackers and smartwatches to measure physical activity in research: analysis of consumer wrist-worn wearables</article-title><source>J Med Internet Res</source><year>2018</year><month>03</month><day>22</day><volume>20</volume><issue>3</issue><fpage>e110</fpage><pub-id pub-id-type="doi">10.2196/jmir.9157</pub-id><pub-id pub-id-type="medline">29567635</pub-id></nlm-citation></ref><ref id="ref30"><label>30</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Xie</surname><given-names>J</given-names> </name><name name-style="western"><surname>Wen</surname><given-names>D</given-names> </name><name name-style="western"><surname>Liang</surname><given-names>L</given-names> </name><name name-style="western"><surname>Jia</surname><given-names>Y</given-names> </name><name name-style="western"><surname>Gao</surname><given-names>L</given-names> </name><name name-style="western"><surname>Lei</surname><given-names>J</given-names> </name></person-group><article-title>Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: comparative study</article-title><source>JMIR Mhealth Uhealth</source><year>2018</year><month>04</month><day>12</day><volume>6</volume><issue>4</issue><fpage>e94</fpage><pub-id pub-id-type="doi">10.2196/mhealth.9754</pub-id><pub-id pub-id-type="medline">29650506</pub-id></nlm-citation></ref><ref id="ref31"><label>31</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bayoumy</surname><given-names>K</given-names> </name><name name-style="western"><surname>Gaber</surname><given-names>M</given-names> </name><name name-style="western"><surname>Elshafeey</surname><given-names>A</given-names> </name><etal/></person-group><article-title>Smart wearable devices in cardiovascular care: where we are and how to move forward</article-title><source>Nat Rev Cardiol</source><year>2021</year><month>08</month><volume>18</volume><issue>8</issue><fpage>581</fpage><lpage>599</lpage><pub-id pub-id-type="doi">10.1038/s41569-021-00522-7</pub-id><pub-id pub-id-type="medline">33664502</pub-id></nlm-citation></ref><ref id="ref32"><label>32</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Phillips</surname><given-names>SM</given-names> </name><name name-style="western"><surname>Summerbell</surname><given-names>C</given-names> </name><name name-style="western"><surname>Hobbs</surname><given-names>M</given-names> </name><etal/></person-group><article-title>A systematic review of the validity, reliability, and feasibility of measurement tools used to assess the physical activity and sedentary behaviour of pre-school aged children</article-title><source>Int J Behav Nutr Phys Act</source><year>2021</year><month>11</month><day>4</day><volume>18</volume><issue>1</issue><fpage>141</fpage><pub-id pub-id-type="doi">10.1186/s12966-021-01132-9</pub-id><pub-id pub-id-type="medline">34732219</pub-id></nlm-citation></ref><ref id="ref33"><label>33</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ngueleu</surname><given-names>AM</given-names> </name><name name-style="western"><surname>Barthod</surname><given-names>C</given-names> </name><name name-style="western"><surname>Best</surname><given-names>KL</given-names> </name><name name-style="western"><surname>Routhier</surname><given-names>F</given-names> </name><name name-style="western"><surname>Otis</surname><given-names>M</given-names> </name><name name-style="western"><surname>Batcho</surname><given-names>CS</given-names> </name></person-group><article-title>Criterion validity of ActiGraph monitoring devices for step counting and distance measurement in adults and older adults: a systematic review</article-title><source>J Neuroeng Rehabil</source><year>2022</year><month>10</month><day>17</day><volume>19</volume><issue>1</issue><fpage>112</fpage><pub-id pub-id-type="doi">10.1186/s12984-022-01085-5</pub-id><pub-id pub-id-type="medline">36253787</pub-id></nlm-citation></ref><ref id="ref34"><label>34</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Aadland</surname><given-names>E</given-names> </name><name name-style="western"><surname>Ylvis&#x00E5;ker</surname><given-names>E</given-names> </name></person-group><article-title>Reliability of the Actigraph GT3X+ Accelerometer in adults under free-living conditions</article-title><source>PLoS One</source><year>2015</year><volume>10</volume><issue>8</issue><fpage>e0134606</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0134606</pub-id><pub-id pub-id-type="medline">26274586</pub-id></nlm-citation></ref><ref id="ref35"><label>35</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Knaier</surname><given-names>R</given-names> </name><name name-style="western"><surname>H&#x00F6;chsmann</surname><given-names>C</given-names> </name><name name-style="western"><surname>Infanger</surname><given-names>D</given-names> </name><name name-style="western"><surname>Hinrichs</surname><given-names>T</given-names> </name><name name-style="western"><surname>Schmidt-Trucks&#x00E4;ss</surname><given-names>A</given-names> </name></person-group><article-title>Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X</article-title><source>BMC Public Health</source><year>2019</year><month>02</month><day>28</day><volume>19</volume><issue>1</issue><fpage>244</fpage><pub-id pub-id-type="doi">10.1186/s12889-019-6568-9</pub-id><pub-id pub-id-type="medline">30819148</pub-id></nlm-citation></ref><ref id="ref36"><label>36</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Sasaki</surname><given-names>JE</given-names> </name><name name-style="western"><surname>John</surname><given-names>D</given-names> </name><name name-style="western"><surname>Freedson</surname><given-names>PS</given-names> </name></person-group><article-title>Validation and comparison of ActiGraph activity monitors</article-title><source>J Sci Med Sport</source><year>2011</year><month>09</month><volume>14</volume><issue>5</issue><fpage>411</fpage><lpage>416</lpage><pub-id pub-id-type="doi">10.1016/j.jsams.2011.04.003</pub-id><pub-id pub-id-type="medline">21616714</pub-id></nlm-citation></ref><ref id="ref37"><label>37</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Freedson</surname><given-names>PS</given-names> </name><name name-style="western"><surname>Melanson</surname><given-names>E</given-names> </name><name name-style="western"><surname>Sirard</surname><given-names>J</given-names> </name></person-group><article-title>Calibration of the Computer Science and Applications, Inc. accelerometer</article-title><source>Med Sci Sports Exerc</source><year>1998</year><month>05</month><volume>30</volume><issue>5</issue><fpage>777</fpage><lpage>781</lpage><pub-id pub-id-type="doi">10.1097/00005768-199805000-00021</pub-id><pub-id pub-id-type="medline">9588623</pub-id></nlm-citation></ref><ref id="ref38"><label>38</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Quante</surname><given-names>M</given-names> </name><name name-style="western"><surname>Kaplan</surname><given-names>ER</given-names> </name><name name-style="western"><surname>Cailler</surname><given-names>M</given-names> </name><etal/></person-group><article-title>Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms</article-title><source>Nat Sci Sleep</source><year>2018</year><volume>10</volume><fpage>13</fpage><lpage>20</lpage><pub-id pub-id-type="doi">10.2147/NSS.S151085</pub-id><pub-id pub-id-type="medline">29403321</pub-id></nlm-citation></ref><ref id="ref39"><label>39</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Airlie</surname><given-names>J</given-names> </name><name name-style="western"><surname>Forster</surname><given-names>A</given-names> </name><name name-style="western"><surname>Birch</surname><given-names>KM</given-names> </name></person-group><article-title>An investigation into the optimal wear time criteria necessary to reliably estimate physical activity and sedentary behaviour from ActiGraph wGT3X+ accelerometer data in older care home residents</article-title><source>BMC Geriatr</source><year>2022</year><month>02</month><day>17</day><volume>22</volume><issue>1</issue><fpage>136</fpage><pub-id pub-id-type="doi">10.1186/s12877-021-02725-6</pub-id><pub-id pub-id-type="medline">35177023</pub-id></nlm-citation></ref><ref id="ref40"><label>40</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rich</surname><given-names>C</given-names> </name><name name-style="western"><surname>Geraci</surname><given-names>M</given-names> </name><name name-style="western"><surname>Griffiths</surname><given-names>L</given-names> </name><name name-style="western"><surname>Sera</surname><given-names>F</given-names> </name><name name-style="western"><surname>Dezateux</surname><given-names>C</given-names> </name><name name-style="western"><surname>Cortina-Borja</surname><given-names>M</given-names> </name></person-group><article-title>Quality control methods in accelerometer data processing: defining minimum wear time</article-title><source>PLoS One</source><year>2013</year><volume>8</volume><issue>6</issue><fpage>e67206</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0067206</pub-id><pub-id pub-id-type="medline">23826236</pub-id></nlm-citation></ref><ref id="ref41"><label>41</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Wahl</surname><given-names>Y</given-names> </name><name name-style="western"><surname>D&#x00FC;king</surname><given-names>P</given-names> </name><name name-style="western"><surname>Droszez</surname><given-names>A</given-names> </name><name name-style="western"><surname>Wahl</surname><given-names>P</given-names> </name><name name-style="western"><surname>Mester</surname><given-names>J</given-names> </name></person-group><article-title>Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions</article-title><source>Front Physiol</source><year>2017</year><volume>8</volume><fpage>725</fpage><pub-id pub-id-type="doi">10.3389/fphys.2017.00725</pub-id><pub-id pub-id-type="medline">29018355</pub-id></nlm-citation></ref><ref id="ref42"><label>42</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tudor-Locke</surname><given-names>C</given-names> </name><name name-style="western"><surname>Barreira</surname><given-names>TV</given-names> </name><name name-style="western"><surname>Schuna</surname><given-names>JM</given-names>  <suffix>Jr</suffix></name></person-group><article-title>Comparison of step outputs for waist and wrist accelerometer attachment sites</article-title><source>Med Sci Sports Exerc</source><year>2015</year><month>04</month><volume>47</volume><issue>4</issue><fpage>839</fpage><lpage>842</lpage><pub-id pub-id-type="doi">10.1249/MSS.0000000000000476</pub-id><pub-id pub-id-type="medline">25121517</pub-id></nlm-citation></ref><ref id="ref43"><label>43</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tudor-Locke</surname><given-names>C</given-names> </name><name name-style="western"><surname>Camhi</surname><given-names>SM</given-names> </name><name name-style="western"><surname>Leonardi</surname><given-names>C</given-names> </name><etal/></person-group><article-title>Patterns of adult stepping cadence in the 2005-2006 NHANES</article-title><source>Prev Med</source><year>2011</year><month>09</month><volume>53</volume><issue>3</issue><fpage>178</fpage><lpage>181</lpage><pub-id pub-id-type="doi">10.1016/j.ypmed.2011.06.004</pub-id><pub-id pub-id-type="medline">21708187</pub-id></nlm-citation></ref><ref id="ref44"><label>44</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fokkema</surname><given-names>T</given-names> </name><name name-style="western"><surname>Kooiman</surname><given-names>TJM</given-names> </name><name name-style="western"><surname>Krijnen</surname><given-names>WP</given-names> </name><name name-style="western"><surname>VAN DER Schans</surname><given-names>CP</given-names> </name><name name-style="western"><surname>DE Groot</surname><given-names>M</given-names> </name></person-group><article-title>Reliability and validity of ten consumer activity trackers depend on walking speed</article-title><source>Med Sci Sports Exerc</source><year>2017</year><month>04</month><volume>49</volume><issue>4</issue><fpage>793</fpage><lpage>800</lpage><pub-id pub-id-type="doi">10.1249/MSS.0000000000001146</pub-id><pub-id pub-id-type="medline">28319983</pub-id></nlm-citation></ref><ref id="ref45"><label>45</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Evenson</surname><given-names>KR</given-names> </name><name name-style="western"><surname>Goto</surname><given-names>MM</given-names> </name><name name-style="western"><surname>Furberg</surname><given-names>RD</given-names> </name></person-group><article-title>Systematic review of the validity and reliability of consumer-wearable activity trackers</article-title><source>Int J Behav Nutr Phys Act</source><year>2015</year><month>12</month><day>18</day><volume>12</volume><fpage>159</fpage><pub-id pub-id-type="doi">10.1186/s12966-015-0314-1</pub-id><pub-id pub-id-type="medline">26684758</pub-id></nlm-citation></ref><ref id="ref46"><label>46</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hajj-Boutros</surname><given-names>G</given-names> </name><name name-style="western"><surname>Landry-Duval</surname><given-names>MA</given-names> </name><name name-style="western"><surname>Comtois</surname><given-names>AS</given-names> </name><name name-style="western"><surname>Gouspillou</surname><given-names>G</given-names> </name><name name-style="western"><surname>Karelis</surname><given-names>AD</given-names> </name></person-group><article-title>Wrist-worn devices for the measurement of heart rate and energy expenditure: a validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense</article-title><source>Eur J Sport Sci</source><year>2023</year><month>02</month><volume>23</volume><issue>2</issue><fpage>165</fpage><lpage>177</lpage><pub-id pub-id-type="doi">10.1080/17461391.2021.2023656</pub-id><pub-id pub-id-type="medline">34957939</pub-id></nlm-citation></ref><ref id="ref47"><label>47</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Falter</surname><given-names>M</given-names> </name><name name-style="western"><surname>Budts</surname><given-names>W</given-names> </name><name name-style="western"><surname>Goetschalckx</surname><given-names>K</given-names> </name><name name-style="western"><surname>Cornelissen</surname><given-names>V</given-names> </name><name name-style="western"><surname>Buys</surname><given-names>R</given-names> </name></person-group><article-title>Accuracy of Apple Watch measurements for heart rate and energy expenditure in patients with cardiovascular disease: cross-sectional study</article-title><source>JMIR Mhealth Uhealth</source><year>2019</year><month>03</month><day>19</day><volume>7</volume><issue>3</issue><fpage>e11889</fpage><pub-id pub-id-type="doi">10.2196/11889</pub-id><pub-id pub-id-type="medline">30888332</pub-id></nlm-citation></ref><ref id="ref48"><label>48</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Price</surname><given-names>K</given-names> </name><name name-style="western"><surname>Bird</surname><given-names>SR</given-names> </name><name name-style="western"><surname>Lythgo</surname><given-names>N</given-names> </name><name name-style="western"><surname>Raj</surname><given-names>IS</given-names> </name><name name-style="western"><surname>Wong</surname><given-names>JYL</given-names> </name><name name-style="western"><surname>Lynch</surname><given-names>C</given-names> </name></person-group><article-title>Validation of the Fitbit One, Garmin Vivofit and Jawbone UP activity tracker in estimation of energy expenditure during treadmill walking and running</article-title><source>J Med Eng Technol</source><year>2017</year><month>04</month><day>3</day><volume>41</volume><issue>3</issue><fpage>208</fpage><lpage>215</lpage><pub-id pub-id-type="doi">10.1080/03091902.2016.1253795</pub-id></nlm-citation></ref><ref id="ref49"><label>49</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Muggeridge</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Hickson</surname><given-names>K</given-names> </name><name name-style="western"><surname>Davies</surname><given-names>AV</given-names> </name><etal/></person-group><article-title>Measurement of heart rate using the Polar OH1 and Fitbit Charge 3 wearable devices in healthy adults during light, moderate, vigorous, and sprint-based exercise: validation study</article-title><source>JMIR Mhealth Uhealth</source><year>2021</year><month>03</month><day>25</day><volume>9</volume><issue>3</issue><fpage>e25313</fpage><pub-id pub-id-type="doi">10.2196/25313</pub-id><pub-id pub-id-type="medline">33764310</pub-id></nlm-citation></ref><ref id="ref50"><label>50</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Reddy</surname><given-names>RK</given-names> </name><name name-style="western"><surname>Pooni</surname><given-names>R</given-names> </name><name name-style="western"><surname>Zaharieva</surname><given-names>DP</given-names> </name><etal/></person-group><article-title>Accuracy of wrist-worn activity monitors during common daily physical activities and types of structured exercise: evaluation study</article-title><source>JMIR Mhealth Uhealth</source><year>2018</year><month>12</month><day>10</day><volume>6</volume><issue>12</issue><fpage>e10338</fpage><pub-id pub-id-type="doi">10.2196/10338</pub-id><pub-id pub-id-type="medline">30530451</pub-id></nlm-citation></ref><ref id="ref51"><label>51</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Chowdhury</surname><given-names>EA</given-names> </name><name name-style="western"><surname>Western</surname><given-names>MJ</given-names> </name><name name-style="western"><surname>Nightingale</surname><given-names>TE</given-names> </name><name name-style="western"><surname>Peacock</surname><given-names>OJ</given-names> </name><name name-style="western"><surname>Thompson</surname><given-names>D</given-names> </name></person-group><article-title>Assessment of laboratory and daily energy expenditure estimates from consumer multi-sensor physical activity monitors</article-title><source>PLoS One</source><year>2017</year><volume>12</volume><issue>2</issue><fpage>e0171720</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0171720</pub-id><pub-id pub-id-type="medline">28234979</pub-id></nlm-citation></ref><ref id="ref52"><label>52</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Argent</surname><given-names>R</given-names> </name><name name-style="western"><surname>Hetherington-Rauth</surname><given-names>M</given-names> </name><name name-style="western"><surname>Stang</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Recommendations for determining the validity of consumer wearables and smartphones for the estimation of energy expenditure: expert statement and checklist of the INTERLIVE network</article-title><source>Sports Med</source><year>2022</year><month>08</month><volume>52</volume><issue>8</issue><fpage>1817</fpage><lpage>1832</lpage><pub-id pub-id-type="doi">10.1007/s40279-022-01665-4</pub-id><pub-id pub-id-type="medline">35260991</pub-id></nlm-citation></ref><ref id="ref53"><label>53</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Meltzer</surname><given-names>LJ</given-names> </name><name name-style="western"><surname>Hiruma</surname><given-names>LS</given-names> </name><name name-style="western"><surname>Avis</surname><given-names>K</given-names> </name><name name-style="western"><surname>Montgomery-Downs</surname><given-names>H</given-names> </name><name name-style="western"><surname>Valentin</surname><given-names>J</given-names> </name></person-group><article-title>Comparison of a commercial accelerometer with polysomnography and actigraphy in children and adolescents</article-title><source>Sleep</source><year>2015</year><month>08</month><day>1</day><volume>38</volume><issue>8</issue><fpage>1323</fpage><lpage>1330</lpage><pub-id pub-id-type="doi">10.5665/sleep.4918</pub-id><pub-id pub-id-type="medline">26118555</pub-id></nlm-citation></ref><ref id="ref54"><label>54</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cook</surname><given-names>JD</given-names> </name><name name-style="western"><surname>Prairie</surname><given-names>ML</given-names> </name><name name-style="western"><surname>Plante</surname><given-names>DT</given-names> </name></person-group><article-title>Utility of the Fitbit Flex to evaluate sleep in major depressive disorder: a comparison against polysomnography and wrist-worn actigraphy</article-title><source>J Affect Disord</source><year>2017</year><month>08</month><day>1</day><volume>217</volume><fpage>299</fpage><lpage>305</lpage><pub-id pub-id-type="doi">10.1016/j.jad.2017.04.030</pub-id><pub-id pub-id-type="medline">28448949</pub-id></nlm-citation></ref><ref id="ref55"><label>55</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Zinkhan</surname><given-names>M</given-names> </name><name name-style="western"><surname>Berger</surname><given-names>K</given-names> </name><name name-style="western"><surname>Hense</surname><given-names>S</given-names> </name><etal/></person-group><article-title>Agreement of different methods for assessing sleep characteristics: a comparison of two actigraphs, wrist and hip placement, and self-report with polysomnography</article-title><source>Sleep Med</source><year>2014</year><month>09</month><volume>15</volume><issue>9</issue><fpage>1107</fpage><lpage>1114</lpage><pub-id pub-id-type="doi">10.1016/j.sleep.2014.04.015</pub-id><pub-id pub-id-type="medline">25018025</pub-id></nlm-citation></ref><ref id="ref56"><label>56</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Full</surname><given-names>KM</given-names> </name><name name-style="western"><surname>Kerr</surname><given-names>J</given-names> </name><name name-style="western"><surname>Grandner</surname><given-names>MA</given-names> </name><etal/></person-group><article-title>Validation of a physical activity accelerometer device worn on the hip and wrist against polysomnography</article-title><source>Sleep Health</source><year>2018</year><month>04</month><volume>4</volume><issue>2</issue><fpage>209</fpage><lpage>216</lpage><pub-id pub-id-type="doi">10.1016/j.sleh.2017.12.007</pub-id><pub-id pub-id-type="medline">29555136</pub-id></nlm-citation></ref><ref id="ref57"><label>57</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Guillodo</surname><given-names>E</given-names> </name><name name-style="western"><surname>Lemey</surname><given-names>C</given-names> </name><name name-style="western"><surname>Simonnet</surname><given-names>M</given-names> </name><etal/></person-group><article-title>Clinical applications of mobile health wearable-based sleep monitoring: systematic review</article-title><source>JMIR Mhealth Uhealth</source><year>2020</year><month>04</month><day>1</day><volume>8</volume><issue>4</issue><fpage>e10733</fpage><pub-id pub-id-type="doi">10.2196/10733</pub-id><pub-id pub-id-type="medline">32234707</pub-id></nlm-citation></ref><ref id="ref58"><label>58</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Yang</surname><given-names>L</given-names> </name><name name-style="western"><surname>Kuang</surname><given-names>A</given-names> </name><name name-style="western"><surname>Xu</surname><given-names>C</given-names> </name><etal/></person-group><article-title>Design principles in mHealth interventions for sustainable health behavior changes: protocol for a systematic review</article-title><source>JMIR Res Protoc</source><year>2023</year><month>02</month><day>22</day><volume>12</volume><fpage>e39093</fpage><pub-id pub-id-type="doi">10.2196/39093</pub-id><pub-id pub-id-type="medline">36811938</pub-id></nlm-citation></ref><ref id="ref59"><label>59</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Scott</surname><given-names>JJ</given-names> </name><name name-style="western"><surname>Rowlands</surname><given-names>AV</given-names> </name><name name-style="western"><surname>Cliff</surname><given-names>DP</given-names> </name><name name-style="western"><surname>Morgan</surname><given-names>PJ</given-names> </name><name name-style="western"><surname>Plotnikoff</surname><given-names>RC</given-names> </name><name name-style="western"><surname>Lubans</surname><given-names>DR</given-names> </name></person-group><article-title>Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents</article-title><source>J Sci Med Sport</source><year>2017</year><month>12</month><volume>20</volume><issue>12</issue><fpage>1101</fpage><lpage>1106</lpage><pub-id pub-id-type="doi">10.1016/j.jsams.2017.04.017</pub-id><pub-id pub-id-type="medline">28501418</pub-id></nlm-citation></ref></ref-list></back></article>